General-Fujitsu AOG18UNAKL [12/40] Simple remote controlle

General-Fujitsu ASHA14LCC [12/40] Simple remote controlle
060
CASSETTE
INVERTER
Specifications
Capacity
EER
COP
Running Current
Moisture Removal
Airflow Rate (High)
Sound Pressure
Net Dimension H
x
W
x
D
Net Weight
Piping Connections (Small / Large)
Max Height Difference
Operation Range
Cooling
Heating
Drain Pipe Diameter (I.D./O.D.)
Max Pipe Length (Pre-Charge)
Refrigerant
Cassette Grille
Heating
Cooling/HeatingInput Power
Power Source
Cooling
Cooling
Indoor
Outdoor
Indoor (High)
Outdoor
Heating
Cooling/Heating
Indoor / Grille
Outdoor
°CDB
mm
m
kg(lbs)
mm
kW
kg(lbs)
A
W/W
m
3
/h
I/h
dB(A)
mm
V/ Ø/Hz
kW
BTU/h
kW
BTU/h
Model No.
Indoor unit
Outdoor unit
AUGG30LRLA-A
AOGG30LBTA-A
230/1/50
8.50
29,000
10.00
34,100
2.65/2.77
3.21
3.61
11.6/12.2
2.5
40
53
1,600
3,600
288x840x840/50x950x950
26.0(57)/5.5(12)
830x900x330
61.0(135)
9.52/15.88
25.0/32.0
50(20)
30
-15 to 46
-15 to 24
R410A
UTG-UGGA-W
AUGG36LRLA-A
AOGG36LBTA-A
230/1/50
10.00
34,100
11.20
38,200
3.12/3.02
3.21
3.71
13.7/13.3
3.5
43
54
1,800
3,800
288x840x840/50x950x950
26.0(57)/5.5(12)
830x900x330
61.0(135)
9.52/15.88
25.0/32.0
50(20)
30
-15 to 46
-15 to 24
R410A
UTG-UGGA-W
AUGG54LRLA-A
AOGG54LBTA-A
230/1/50
13.3
45,400
16.0
54,600
4.42/4.69
3.01
3.41
19.3/20.5
5.0
47
55
2,000
6,750
288x840x840/50x950x950
27.0(60)/5.5(12)
1290×900×330
88.0(194)
9.52/15.88
25.0/32.0
50(20)
30
-15 to 46
-15 to 24
R410A
UTG-UGGA-W
AUGG45LRLA-A
AOGG45LBTA-A
230/1/50
12.50
42,700
14.00
47,800
3.90/3.77
3.21
3.71
17.0/16.5
4.5
46
55
1,900
6,750
288x840x840/50x950x950
27.0(60)/5.5(12)
1290×900×330
88.0(194)
9.52/15.88
25.0/32.0
50(20)
30
-15 to 46
-15 to 24
R410A
UTG-UGGA-W
For AUGG30/36LRLA-AWired R.C. For AUGG45/45LRLA-A
Model : AUGG30LRLA-A / AUGG36LRLA-A / AUGG45LRLA-A / AUGG54LRLA-A
Single
phase
High efficiency turbo fan with 3-dimensional blade
450mm
500mm
Wind
velocity
Heat exchanger
< Motor side >
Uneven airflow
Fast
Slow
Conventional blade
Separation
phenomenon of
airflow
causes noise
: Spin direction : Airflow direction : Turbulent flow noise
< Motor side >
Heat exchanger
3-dimensional blade
No airflow
separation
Previous turbo fan: Air passing through the heat
exchanger was uneven and the air would only flow close to
the ceiling.
New turbo fan: High efficiency airflow distribution has been
achieved by the introduction of a 3 dimensional blade which
increases the air passing over the heat exchanger.
Quiet
061
SPLIT / INVERTER
Split
Dimensions Models: (Unit : mm)
High lift drain pump
Optional parts
Wired Remote Controller:
Simple Remote Controller
:
IR Receiver Kit:
Wide Panel:
Panel Spacer:
Air Outlet Shutter Plate:
Insulation Kit For High Humidity:
External Connect Kit:
External Control Set:
Fresh Air Intake Kit:
UTY-RNNGM
UTY-RSNGM
UTY-LRHGA2
UTG-AGYA-W
UTG-BGYA-W
UTR-YDZC
UTZ-KXGA
UTY-XWZX
UTY-XWZXZ2
UTY-XWZXZ3
UTD-ECS5A
UTZ-VXGA
Ceiling panel
850mm
Low ambient operation
358
98133
118
158
288
Drain pipe
Liquid pipe
Side view
Top view
Gas pipe
338
278
950
950
Bottom view
890 (Ceiling openings)
699 (Bolt pitch)
796 (Bolt pitch)
842
(indoor unit)
50
40
30
20
10
0
-10
-15°C
Cooling
24°C
Heating
46°C
-15°C
AUGG30LRLA-A / AUGG36LRLA-A / AUGG45LRLA-A / AUGG54LRLA-A
Detachable
Grille corner
Adjustment can be done
just taking off the corner part
Improvement of the airflow distribution
Adjustment of hanger position is possible
after installation
New louvre: The louvre design distributes air leaving a space between the
chassis and the ceiling allowing far and wide air flow distribution.
Much less temperature irregularity
happens by spreading airflow widely
Bottom view
Front part
Ceiling
Rear part
Round louvre
Low noise mode of outdoor unit (45/54 types)
2 stage low noise mode can be selected.(Option)
Roted noise value
Mode 1
Mode 2
Low
noise