General-Fujitsu AOH20FSBV2 [12/28] Error contents

General-Fujitsu AOH20FSBV2 [12/28] Error contents
ERROR CONTENTS
INDOOR UNIT (Cassette type)
: Fast flashing : Slow flashing
OPERATION
lamp
TIMER
lamp
Error display
Error contents
SWING
lamp
Goes off
Goes off
Goes off
Goes off
Goes off
4 times
2 times
3 times
6 times
Model information abnormal
(permanent type)
Drain abnormal
(permanent type)
Room air temperature
thermistor open circuit
Room air temperature
thermistor short circuit
Indoor fan abnormal
Piping thermistor open circuit
Piping thermistor short circuit
INDOOR UNIT (Wallmounted type)
: Fast flashing : Slow flashing
When an error occurs, "Large division indication" is indicated first.
Secondly, "Small division indication" is indicated by pushing "Test" button of remote controller.
Operation lamp
: Red lamp
Timer lamp : Green lamp
Error contents Error contents
thermistor error Red lamp
(2 times) thermistor error (room temp.) Red lamp
Green lamp Green lamp (2 times)
thermistor error (heat exchanger) Red lamp
Green lamp (3 times)
control unit error Red lamp (4 times) MANUAL AUTO button error Red lamp
(indoor unit ) Green lamp
Green lamp
(2 times)
power source Hz decision error Red lamp
Green lamp (4 times)
fan motor error Red lamp (6 times) lock error Red lamp
(indoor unit) Green lamp
Green lamp
(2 times)
r.p.m error Red lamp
Green lamp (3 times)
LED indication LED indication
Small division indicationLarge division indication
----- -----
-----
Red lamp
Green lamp
(indoor unit )
circuit board error
112006.03.01

Содержание