General-Fujitsu ASYG09LECA [2/22] Weight
![General-Fujitsu ASYG07LECA [2/22] Weight](/views2/1805366/page2/bg2.png)
S P E C I F I C A T I O N S
TYPE Cool & heat inverter
INDOOR UNIT ASYG09LECA
OUTDOOR UNIT
AOYG09LEC
COOLING CAPACITY
2.50 kW
HEATING CAPACITY
3.20 kW
POWER SOURCE
230 V
FREQUENCY 50 Hz
RUNNING
CURRENT
MAXIMUM
CURRENT
3.5 A
3.8 A
INPUT
WATTS
0.640 kW
0.750 kW
E.E.R. Cooling 3.91 kW/kW
COP
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
Cooling
Heating
4.27 kW/kW
MOISTURE REMOVAL
AIR CIRCULATION
HIGH
ASYG07LECA
AOYG07LEC
2.10 kW
3.00 kW
230 V
50 Hz
2.7 A
3.5 A
6.0 A
7.5 A
0.470 kW
0.685 kW
4.47 kW/kW
4.38 kW/kW
1.3 L/h
690 m
3
/h
710 m
3
/h
FAN MOTOR
POWER SOURCE
230 V
High speed
INDOOR
UNIT
Cooling
Middle speed
Low speed
Quiet
High speed
INDOOR
UNIT
Heating
Middle speed
Low speed
Quiet
High speed
Middle speed
Low speed
Quiet
1,400 r.p.m.
1,200 r.p.m.
920 r.p.m.
620 r.p.m.
1,440 r.p.m.
1,200 r.p.m.
980 r.p.m.
670 r.p.m.
OUTDOOR UNIT Heating
650 r.p.m.
OUTDOOR UNIT Cooling
730 r.p.m.
ELECTRICAL DATA
INDOOR
UNIT
Cooling
High speed
Middle speed
Low speed
Quiet
INDOOR
UNIT
Heating
OUTDOOR UNIT Heating
NOISE LEVEL
43 dB
38 dB
31 dB
21 dB
43 dB
38 dB
31 dB
21 dB
45 dB
OUTDOOR UNIT Cooling 45 dB
2011.03.02 1
COMPRESSOR TYPE
Hermetic type,
4 pole, 3 phase,
DC inverter motor,
Rotary
DISCRIMINATION
5SS072XAA
PRECHARGED REFRIGERANT
REFRIGERANT TYPE
R410A
650 g
650 g
WEIGHT (with oil)
5.9 kg
COMPRESSOR AND REFRIGERANT
Pipe length
15 m
FULL CHARGE
20 m 750 g
MAXIMUM PIPING HEIGHT
15m
ADDITIONAL REFRIGERANT
20 g/m
WEIGHT
INDOOR UNIT Shipping / Net
Shipping / Net
9.5 kg / 7.5 kg
OUTDOOR UNIT
26 kg / 23 kg
INDOOR UNIT H x W x D
H x W x D
260 x 790 x 198 mm
OUTDOOR UNIT
540 x 660 x 290 mm
DIMENSIONS
Содержание
- Aoyg07lec 1
- Aoyg09lec 1
- Asyg07leca 1
- Asyg09leca 1
- Contents 1
- Indoor unit outdoor unit 1
- Split type room air conditioner wall mounted type 1
- Compressor and refrigerant 2
- Dimensions 2
- Electrical data 2
- Fan motor 2
- Noise level 2
- Specifications 2
- Weight 2
- Dimensions 3
- Refrigerant system diagram 4
- 2 3 l n 5
- Circuit diagram 5
- Compressor reactor 5
- Controller pcb assy 5
- Controller pcb assy main pcb 5
- Earth terminal 5
- Expansion valve 5
- Fan motor 5
- Indicator pcb assy 5
- Indoor unit 5
- Louver 5
- Outdoor unit 5
- Pipe temp 5
- Power source 5
- Room temp 5
- Terminal 5
- Thermistor assy 5
- Thermistor discharge temp 5
- Thermistor outdoor temp 5
- Thermistor pipe temp 5
- To communication board option 5
- Way valve 5
- Communication pcb assembly k08dg 0801hse ca0 6
- Control unit asyg07leca ez 0101shse asyg09leca ez 0101thse 6
- Controller pcb assembly main pcb asyg07leca k09ds 100dhse c1 asyg09leca k09ds 100ehse c1 6
- Indicator pcb assembly k07bj 0900hsd d0 6
- Indoor pcb circuit diagram 6
- Option 6
- Thermistor pipe temp 6
- Thermistor room temp 6
- Wired remote control option 6
- Indoor unit controller pcb assembly main pcb asyg07leca k09ds 100dhse c1 asyg09leca k09ds 100ehse c1 7
- Indoor unit indicator pcb assembly k07bj 0900hsd d0 8
- Communication pcb assembly k08dg 0801hse ca0 9
- Model uty xcbxe 9
- To controller pcb assenbly 9
- To wired remote control 9
- Compressor 10
- Controller pcb assembly aoyg07lec k10bo 100bhue c1 aoyg09lec k10bo 100chue c1 10
- Dc fan motor 10
- Electric expansion valve 10
- Inverter assembly aoyg07lec ez 0100hhue aoyg09lec ez 0100khue 10
- Outdoor pcb circuit diagram 10
- Power source ac230v 50hz 10
- Reactor 10
- Terminal 10
- To indoor unit 10
- Way valve 10
- 3 2 10 11
- Outdoor unit controller pcb assembly aoyg07lec k10bo 100bhue c1 aoyg09lec k10bo 100chue c1 11
- 0 s on 0 s off 12
- 3 2 11 12
- Error code 12
- Error detection 12
- If you use a wireless remote control the lamp on the photo detector unit will output error codes by way of blinking patterns if you use a wired remote control error codes will appear on the remote control display see the lamp blinking patterns and error codes in the table an error display is displayed only during operation 12
- Indoor unit display 12
- Indoor unit remote control 12
- Number of flashing 12
- Wired remote control display option if an error occurs the following display will be shown er will appear in the set room temperature display 12
- Outdoor unit 13
- Indoor unit front panel 14
- Indoor unit casing assy 15
- Indoor unit control box 16
- Indoor unit evaporator 17
- Outdoor unit 18
- Outdoor unit 19
- Outdoor unit 20
- Accessories 21
Похожие устройства
- General-Fujitsu ASYG12LECA Сервис мануал
- General-Fujitsu ASYG14LECA Сервис мануал
- General-Fujitsu AOYG07LEC Сервис мануал
- General-Fujitsu AOYG09LEC Сервис мануал
- General-Fujitsu AOYG12LEC Сервис мануал
- General-Fujitsu AOYG14LEC Сервис мануал
- General-Fujitsu AUH12LBAB Сервис мануал
- General-Fujitsu AUH14LBAB Сервис мануал
- General-Fujitsu AUH18LBAB Сервис мануал
- General-Fujitsu AOH18LMAK2 Сервис мануал
- General-Fujitsu AOH18LMAK2 Брошюра
- General-Fujitsu ASH12UMBD Сервис мануал
- General-Fujitsu AUH12UMAB Сервис мануал
- General-Fujitsu AOH24USBV2 Сервис мануал
- General-Fujitsu ASY12EMBCW Сервис мануал
- General-Fujitsu ASH12EMBCW Сервис мануал
- General-Fujitsu AOY32ESAM4 Сервис мануал
- General-Fujitsu AOH32ESAM4 Сервис мануал
- General-Fujitsu AWG24FBAJ Сервис мануал
- General-Fujitsu AWG24UBAJ Сервис мануал