General-Fujitsu AOYG12LEC [12/22] Error detection
![General-Fujitsu AOYG07LEC [12/22] Error detection](/views2/1805366/page12/bgc.png)
If you use a wireless remote control, the lamp
on the photo detector unit will output error codes
by way of blinking patterns.
If you use a wired remote control, error codes
will appear on the remote control display.
See the lamp blinking patterns and error codes
in the table.
An error display is displayed only during operation.
Indoor unit
Wired
remote
control
Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
Indoor unit
Wired
remote
control
Description
OPERATION
lamp
(green)
TIMER
lamp
(orange)
ECONOMY
lamp
(green)
(1)
(1)
Serial communication error
(1)
(2)
Wired remote control
communication error
(1)
(5)
Check run unfinished
(2)
(2)
Indoor unit capacity error
(2)
(3)
Combination error
(3)
(2)
Indoor unit PCB model
information error
(3)
(5)
Manual auto switch error
(4)
(1)
Room temp. sensor error
(4)
(2)
Indoor unit Heat Ex. Middle temp.
sensor error
(5)
(1)
Indoor unit fan motor error
(5)
(3)
Drain pump error
(5)
(7)
Damper error
(5)
(15)
Indoor unit error
(6)
(2)
Outdoor unit main PCB model
information error or
communication error
(6)
(3)
Inverter error
(6)
(4)
Active filter error,
PFC circuit error
(6)
(5)
Trip terminal L error
(6)
(10)
Display PCB microcomputers
communication error
(7)
(1)
Discharge temp. sensor error
(7)
(2)
Compressor temp. sensor error
(7)
(3)
Outdoor unit Heat Ex. liquid
temp. sensor error
(7)
(4)
Outdoor temp. sensor error
(7)
(5)
Suction Gas temp. sensor error
(7)
(6)
2-way valve temp. sensor error•
3-way valve temp. sensor error•
(7)
(7)
Heat sink temp. sensor error
(8)
(2)
Sub-cool Heat Ex. gas inlet •
temp. sensor error
Sub-cool Heat Ex. gas outlet •
temp. sensor error
(8)
(3)
Liquid pipe temp. sensor error
(8)
(4)
Current sensor error
(8)
(6)
Discharge pressure sensor error•
Suction pressure sensor error•
High pressure switch error•
(9)
(4)
Trip detection
(9)
(5)
Compressor rotor position
detection error (permanent stop)
(9)
(7)
Outdoor unit fan motor error
(9)
(9)
4-way valve error
(10)
(1)
Discharge temp. error
(10)
(3)
Compressor temp. error
(10)
(4)
High pressure error
(10)
(5)
Low pressure error
Indoor unit display
OPERATION OPERATION lamp (green)
TIMER
TIMER lamp (orange)
ECONOMY
ECONOMY lamp (green)
Wired remote control display (Option)
If an error occurs, the following display will be shown.
(“Er” will appear in the set room temperature display.)
Error code
E R R O R D E T E C T I O N
2011.03.02 11
: 0.5s ON / 0.5s OFF
: 0.1s ON / 0.1s OFF
( ) : Number of flashing
INDOOR UNIT
REMOTE CONTROL
Содержание
- Aoyg07lec 1
- Aoyg09lec 1
- Asyg07leca 1
- Asyg09leca 1
- Contents 1
- Indoor unit outdoor unit 1
- Split type room air conditioner wall mounted type 1
- Compressor and refrigerant 2
- Dimensions 2
- Electrical data 2
- Fan motor 2
- Noise level 2
- Specifications 2
- Weight 2
- Dimensions 3
- Refrigerant system diagram 4
- 2 3 l n 5
- Circuit diagram 5
- Compressor reactor 5
- Controller pcb assy 5
- Controller pcb assy main pcb 5
- Earth terminal 5
- Expansion valve 5
- Fan motor 5
- Indicator pcb assy 5
- Indoor unit 5
- Louver 5
- Outdoor unit 5
- Pipe temp 5
- Power source 5
- Room temp 5
- Terminal 5
- Thermistor assy 5
- Thermistor discharge temp 5
- Thermistor outdoor temp 5
- Thermistor pipe temp 5
- To communication board option 5
- Way valve 5
- Communication pcb assembly k08dg 0801hse ca0 6
- Control unit asyg07leca ez 0101shse asyg09leca ez 0101thse 6
- Controller pcb assembly main pcb asyg07leca k09ds 100dhse c1 asyg09leca k09ds 100ehse c1 6
- Indicator pcb assembly k07bj 0900hsd d0 6
- Indoor pcb circuit diagram 6
- Option 6
- Thermistor pipe temp 6
- Thermistor room temp 6
- Wired remote control option 6
- Indoor unit controller pcb assembly main pcb asyg07leca k09ds 100dhse c1 asyg09leca k09ds 100ehse c1 7
- Indoor unit indicator pcb assembly k07bj 0900hsd d0 8
- Communication pcb assembly k08dg 0801hse ca0 9
- Model uty xcbxe 9
- To controller pcb assenbly 9
- To wired remote control 9
- Compressor 10
- Controller pcb assembly aoyg07lec k10bo 100bhue c1 aoyg09lec k10bo 100chue c1 10
- Dc fan motor 10
- Electric expansion valve 10
- Inverter assembly aoyg07lec ez 0100hhue aoyg09lec ez 0100khue 10
- Outdoor pcb circuit diagram 10
- Power source ac230v 50hz 10
- Reactor 10
- Terminal 10
- To indoor unit 10
- Way valve 10
- 3 2 10 11
- Outdoor unit controller pcb assembly aoyg07lec k10bo 100bhue c1 aoyg09lec k10bo 100chue c1 11
- 0 s on 0 s off 12
- 3 2 11 12
- Error code 12
- Error detection 12
- If you use a wireless remote control the lamp on the photo detector unit will output error codes by way of blinking patterns if you use a wired remote control error codes will appear on the remote control display see the lamp blinking patterns and error codes in the table an error display is displayed only during operation 12
- Indoor unit display 12
- Indoor unit remote control 12
- Number of flashing 12
- Wired remote control display option if an error occurs the following display will be shown er will appear in the set room temperature display 12
- Outdoor unit 13
- Indoor unit front panel 14
- Indoor unit casing assy 15
- Indoor unit control box 16
- Indoor unit evaporator 17
- Outdoor unit 18
- Outdoor unit 19
- Outdoor unit 20
- Accessories 21
Похожие устройства
- General-Fujitsu AOYG14LEC Сервис мануал
- General-Fujitsu AUH12LBAB Сервис мануал
- General-Fujitsu AUH14LBAB Сервис мануал
- General-Fujitsu AUH18LBAB Сервис мануал
- General-Fujitsu AOH18LMAK2 Сервис мануал
- General-Fujitsu AOH18LMAK2 Брошюра
- General-Fujitsu ASH12UMBD Сервис мануал
- General-Fujitsu AUH12UMAB Сервис мануал
- General-Fujitsu AOH24USBV2 Сервис мануал
- General-Fujitsu ASY12EMBCW Сервис мануал
- General-Fujitsu ASH12EMBCW Сервис мануал
- General-Fujitsu AOY32ESAM4 Сервис мануал
- General-Fujitsu AOH32ESAM4 Сервис мануал
- General-Fujitsu AWG24FBAJ Сервис мануал
- General-Fujitsu AWG24UBAJ Сервис мануал
- General-Fujitsu AOG24FNAD Сервис мануал
- General-Fujitsu AOG24UNADL Сервис мануал
- General-Fujitsu ASYG07LUCA Сервис мануал
- General-Fujitsu ASYG09LUCA Сервис мануал
- General-Fujitsu AOYG07LUC Сервис мануал