General-Fujitsu AOYG12LUC [3/22] Dimensions
![General-Fujitsu ASYG12LUCA [3/22] Dimensions](/views2/1805588/page3/bg3.png)
D I M E N S I O N S
unit : mm
282
185
870
2011.04.14 2
INDOOR UNIT
Drain pipe diameter
16.2 mm
Liquid pipe diameter : 6.35 mm
Gas pipe diameter : 9.52 mm
OUTDOOR UNIT
540
290790
540
Содержание
- Aoyg12luc 1
- Aoyg14luc 1
- Asyg12luca 1
- Asyg14luca 1
- Contents 1
- Indoor unit outdoor unit 1
- Split type room air conditioner wall mounted type 1
- Compressor and refrigerant 2
- Dimensions 2
- Electrical data 2
- Fan motor 2
- Noise level 2
- Specifications 2
- Weight 2
- Dimensions 3
- Refrigerant system diagram 4
- 2 3 l n 5
- Circuit diagram 5
- Compressor 5
- Controller pcb assy 5
- Controller pcb assy main pcb 5
- Earth terminal 5
- Expansion valve 5
- Fan motor 5
- Indicator pcb assy 5
- Indoor unit 5
- Louver up down m 5
- M open panel 5
- Outdoor unit 5
- Panel limit switch 5
- Power source 5
- Reactor 5
- Terminal 5
- Terminal 1 2 3 5
- Thermistor discharge temp 5
- Thermistor outdoor temp 5
- Thermistor pipe temp 5
- Thermistor room temp 5
- To communication kit option 5
- Way valve 5
- Communication pcb assembly option k10dc 1000hse ca0 6
- Control unit asyg12luca ez 0100thse asyg14luca ez 0100whse 6
- Controller pcb assembly main pcb asyg12luca k10ch 1002hse c1 asyg14luca k10ch 1003hse c1 6
- Fan motor 6
- Indicator pcb assembly k10cx 1000hse d0 6
- Indoor pcb circuit diagram 6
- Louver up down 6
- Open panel 6
- Option 6
- Outdoor unit 6
- Panel limit switch 6
- Indoor unit controller pcb assembly main pcb asyg12luca k10ch 1002hse c1 asyg14luca k10ch 1003hse c1 7
- Indoor unit indicator pcb assembly k10cx 1000hse d0 8
- Compressor 9
- Controller pcb assembly aoyg12luc k10bo 1000hue c1 aoyg14luc k10bo 1001hue c1 9
- Dc fan motor 9
- Electric expansion valve 9
- Inverter assembly aoyg12luc ez 010dhue aoyg14luc ez 01008hue 9
- Outdoor pcb circuit diagram 9
- To indoor unit 9
- Way valve 9
- Outdoor unit controller pcb assembly aoyg12luc k10bo 1000hue c1 aoyg14luc k10bo 1001hue c1 10
- 0 s on 0 s off 11
- 4 1 10 11
- Error code 11
- Error detection 11
- If you use a wireless remote control the lamp on the photo detector unit will output error codes by way of blinking patterns if you use a wired remote control error codes will appear on the remote control display see the lamp blinking patterns and error codes in the table an error display is displayed only during operation 11
- Indoor unit display 11
- Indoor unit remote control 11
- Number of flashing 11
- Wired remote control display option if an error occurs the following display will be shown er will appear in the set room temperature display 11
- Outdoor unit 12
- Indoor unit 13
- Indoor unit front panel 14
- Indoor unit evaporator 15
- Indoor unit control box 16
- Indoor unit casing assy 17
- Outdoor unit 18
- Outdoor unit 19
- Outdoor unit 20
- Accessories 21
Похожие устройства
- General-Fujitsu AOYG14LUC Сервис мануал
- General-Fujitsu ASHA14LGC Сервис мануал
- General-Fujitsu AOHR14LGC Сервис мануал
- General-Fujitsu ARG60ALA3 Сервис мануал
- General-Fujitsu ARG60RLA3 Сервис мануал
- General-Fujitsu AOG60ABA3L Сервис мануал
- General-Fujitsu AOG60RBA3L Сервис мануал
- General-Fujitsu ASH9ASGCW Сервис мануал
- General-Fujitsu ASH9RSGCW Сервис мануал
- General-Fujitsu ASH12ASGCW Сервис мануал
- Mazzoni MMD12250R Инструкция по эксплуатации
- Mazzoni MMD12250R Спецификации
- Mazzoni MMD12250R Каталог
- Mazzoni MMD15250R Инструкция по эксплуатации
- Mazzoni MMD15250R Спецификации
- Mazzoni MMD15250R Каталог
- Mazzoni MMD18250R Инструкция по эксплуатации
- Mazzoni MMD18250R Спецификации
- Mazzoni MMD18250R Каталог
- Mazzoni MMD21250R Инструкция по эксплуатации