General-Fujitsu ASYG09LECB [5/23] Compressor
Превью страниц
Страница 5 /
23
![General-Fujitsu ASYG09LECB [5/23] Compressor](/views2/1806402/page5/bg5.png)
REACTOR
W10
COMPRESSOR
FAN MOTOR
EXPANSION
VALVE
4-WAY VALVE
HEATER
THERMOSTAT ( 55 )
FUSE 250V 5A x 2
FUSE 250V 20A
FUSE 250V 5A
TERMINAL
POWER SOURCE
( PIPE TEMP. )
( DISCHARGE PIPE )
THERMISTOR ASSY
THERMISTOR
( OUTDOOR TEMP. )
MAIN PCB
CM
FM
PMV
4WV
R
S
C
W11
W4
W2
W1
W3
CN71
CN70
CN40
CN30
CN10
CN800
U W7
V W8
W W9
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
1
2
3
4
5
1
2
3
1
2
3
1
2
3
4
1
2
3
4
1
2
3
1
2
3
1
2
3
4
5
1
2 3
4
5
3
2
1
3
2
1
RED
WHITE
BLACK
RED
BLACK
WHITE
YELLOW
BROWN
RED
BLUE
ORANGE
YELLOW
WHITE
BLACK
BLACK
BLACK
WHITE
BLACK
WHITE
BLACK
BLACK
WHITE
GREEN
GREEN
BLACK
BLACK
BLACK
WHITE
BLACK
BLACK
BLACK
BLACK
BROWN
BROWN
RED
BLACK
WHITE
WHITE
RED
1 2 3 L N
RED
ORANGE
YELLOW
PINK
BLUE
BLACK
BLACK
BLACK
BLACK
RED
WHITE
WHITE
WHITE
WHITE
WHITE
WHITE
BLUE
YELLOW
WHITE
BLACK
RED
BLACK
WHITE
RED
GREEN
1 2 3 4
5
6 7 8
1
2
3
4
5
6
7
1 2 3 4
5
1 2 3 4
5
1
2
3
4
5
6
7
1
2
3
4
5
6
7
1
2
3
4
5
6
1
2
3
4
5
6
1
2
3
4
5
1
2
3
4
5
1
2
3
4
1
2
3
4
1
2
3
4
5
CN1
W4
CN7
CN6
CN4
CN3
CN5
CN8
THERMAL
FUSE 102
CN201
F M
FAN MOTOR
INDICATOR PCB
M
LOUVER
THERMISTOR
( PIPE TEMP. )
THERMISTOR
( ROOM TEMP. )
TEST
1
2 3
EARTH
TERMINAL
TERMINAL
MAIN PCB
INDOOR UNIT
OUTDOOR UNIT
C I R C U I T D I A G R A M
2012.11.16 4
Содержание
59- Aoyg09lecan
- Aoyg12lecan
- Split type room air conditioner wall mounted type
- Indoor unit outdoor unit
- Contents
- Asyg12lecb
- Asyg09lecb
- Fan motor
- Weight
- Specifications
- Noise level
- Electrical data
- Dimensions
- Compressor and refrigerant
- Dimensions
- Refrigerant system diagram
- Compressor
- Circuit diagram
- Way valve
- Thermistor assy
- Terminal
- Outdoor unit
- Main pcb
- Indoor unit
- Heater
- Fan motor
- Expansion valve
- Louver
- Indoor pcb circuit diagram
- Indicator pcb k07bj 0900hsd d0
- Dc fan motor
- Control unit asyg09lecb ez 01214hse asyg12lecb ez 01215hse
- Indoor unit main pcb asyg09lecb k09ds 1206hse c1 asyg12lecb k09ds 1207hse c1
- Indoor unit indicator pcb k07bj 0900hsd d0
- To i ntdoor unit
- Outdoor pcb circuit diagram
- Main pcb aoyg09lecan k10ct 120bhue c1 aoyg12lecan k10ct 120chue c1
- Inverter assembly aoyg09lecan ez 01219hue aoyg12lecan ez 0121ahue
- Outdoor unit main pcb aoyg09lecan k10ct 120bhue c1 aoyg12lecan k10ct 120chue c1
- Wired remote control display option if an error occurs the following display will be shown er will appear in the set room temperature display
- Number of flashing
- Indoor unit remote control
- Indoor unit display
- If you use a wireless remote control the lamp on the photo detector unit will output error codes by way of blinking patterns if you use a wired remote control error codes will appear on the remote control display see the lamp blinking patterns and error codes in the table an error display is displayed only during operation
- Error detection
- Error code
- 3 2 10
- 0 s on 0 s off
- Outdoor unit
- Indoor unit front panel
- Indoor unit control box
- Indoor unit casing assy
- Indoor unit asyg09lecb evaporator
- Indoor unit asyg12lecb evaporator
- Outdoor unit
- Outdoor unit
- Outdoor unit aoyg09lecan
- Outdoor unit aoyg12lecan
- Accessories
Похожие устройства
-
General-Fujitsu ARG36ALC3Сервис мануал -
General-Fujitsu ASYG12LLCAСервис мануал -
General-Fujitsu ASYG09LLCAСервис мануал -
General-Fujitsu ASHA12LGCСервис мануал -
General-Fujitsu ASHA09LGCСервис мануал -
General-Fujitsu AWYZ18LBCСервис мануал -
General-Fujitsu AWYZ14LBCСервис мануал -
General-Fujitsu AWG14UBBJСервис мануал -
General-Fujitsu ASH12USBCWСервис мануал -
General-Fujitsu ASH9USBCWСервис мануал -
General-Fujitsu AUT45ALB3WСервис мануал -
General-Fujitsu AUT36ALC3WСервис мануал