Haier HSU-12H03/V(ZXF) [2/8] Fixing of outdoor unit
![Haier HSU-12H03/V(ZXF) [2/8] Fixing of outdoor unit](/views2/1807701/page2/bg2.png)
Fixing of outdoor unit
Indoor Unit
Selection of Installation Place
Power Source
Selection of pipe
Outdoor Unit
Fix the unit to concrete or block with bolts( 10mm) and nuts firmly and horizontally.
When fitting the unit to wall surface, roof or rooftop, fix a supporter surely with nails
or wires in consideration of earthquake and strong wind.
If vibration may affect the house, fix the unit by attaching a vibration-proof mat.
Place, robust not causing vibration, where the body can be supported
sufficiently.
Place, not affected by heat or steam generated in the vicinity, where
inlet and outlet of the unit are not disturbed.
Place, possible to drain easily, where piping can be connected with the
outdoor unit.
Place, where cold air can be spread in a room entirely.
Place, nearby a power receptacle, with enough space around. (Refer
to drawings).
Place where the distance of more than lm from televisions, radios,
wireless apparatuses and fluorescent lamps can be left.
In the case of fixing the remote controller on a wall, place where the
indoor unit can receive signals when the fluorescent lamps in the room
are lightened.
Place, which is less affected by rain or direct sunlight and is
sufficiently ventilated.
Place, possible to bear the unit, where vibration and noise are
not increased.
Place, where discharged wind and noise do not cause a
nuisance to the neighbors.
Place, where a distance marked is available as illustrated
in the above figure.
Before inserting power plug into receptacle, check the voltage without fail. The power source is the same as the corresponding name plate.
Install an exclusive branch circuit of the power.
A receptacle shall be set up in a distance where the power cable can be reached. Do not extend the cable by cutting it.
To this unit, both liquid and gas pipes shall be insulated
as they become Iow temperature in operation.
Use optional parts for piping set or pipes covered with
equivalent insulation material.
Liquid pipe( )
Gas pipe( )
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
2
6.35mm(1/4")
9.52mm(3/8")
6.35mm(1/4")
12.7mm(1/2")
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
Floor fixing dimensions
of the outdoor unit
(Unit:mm)
9.52mm(3/8")
15.88mm(5/8")
HSU-22C03/V(ZXF)
HSU-22H03/V(ZXF)
HSU-12H03/VA(ZXF)
HSU-12C03/VA(ZXF)
HSU-09H03/VA(ZXF)
HSU-09C03/VA(ZXF) HSU-18C03/V(ZXF)
HSU-18H03/V(ZXF)
HSU-22C03/V(ZF) HSU-22H03/V(ZF)
HSU-12H03/VB(ZXF)
HSU-12H03/V(ZXF)
HSU-24C03/V(ZXF)
HSU-24C03/V(ZF) HSU-24H03/V(ZF) HSU-24H03/V(ZXF)
583 113.5113.5
319.5
500140 140
256
140 415 140
280
For 09 For 12,18 For 22,24
Содержание
- Accessory parts 1
- Drawing for the installation of indoor and outdoor units 1
- Explain sufficiently the operating means to the user according to this manual 1
- Installation manual of room air conditioner 1
- Necessary tools for installation 1
- No 010554405 b 1
- Read this manual before installation 1
- Fix the unit to concrete or block with bolts 10mm and nuts firmly and horizontally when fitting the unit to wall surface roof or rooftop fix a supporter surely with nails or wires in consideration of earthquake and strong wind 2
- Fixing of outdoor unit 2
- If vibration may affect the house fix the unit by attaching a vibration proof mat 2
- Indoor unit 2
- Outdoor unit 2
- Power source 2
- Selection of installation place 2
- Selection of pipe 2
- Carry out based on the neighboring pillars or lintels a proper leveling for the plate to be fixed against the wall then temporarily fasten the plate with one steel nail 2 make sure once more the proper level of the plate by hanging a thread with a weight from the central top of the plate then fasten securely the plate with the attachment steel nail 3 find the wall hole location a using a measuring tape 3
- Drawing of pipe 3
- Fitting of the mounting plate and positioning of the wall hole 3
- Fix to side bar and lintel a mounting bar which is separately sold and then fasten the plate to the fixed mounting bar 3
- Indoor unit 3
- Installation of the indoor unit 3
- Left left rear piping 3
- Making a hole on the wall and fitting the piping hole cover 3
- Rear piping 3
- Refer to the previous article when the mounting plate is first fixed for the position of wall hole 3
- When the mounting plate is first fixed 3
- When the mounting plate is fixed side bar and lintel 3
- Connecting the indoor outdoor electric cable 4
- Fixing the indoor unit body 4
- Indoor unit 4
- Removing the wiring cover 4
- When connecting the cable after installing the indoor unit 4
- When connecting the cable before installing the indoor unit 4
- 2x0 5m 5
- Another way for the models of 18 22 as illustrated 5
- Change for fresh air tube 5
- Connecting wiring mod 12 5g1 m 5
- Drain hose 5
- Fix with adhesive tape 5
- Hsu 18c03 v zxf 5
- Indoor unit 5
- Installation instruction on the indoor part of the fresh air device 5
- Lid for left piping 5
- Lid for under piping 5
- Mod 18 22 24 3g2 m 5
- Mod 22 24 3g2 m 5
- Outdoor unit 5
- Outlet joint 5
- Power cable mod 09 12 18 3g1 m 5
- Attaching drain elbow 6
- Connection 6
- Connection of pipes 6
- Easily demount cleaning of indoor unit 6
- Half union flare nut 6
- Installation of outdoor unit 6
- Outdoor unit 6
- Spanner 6
- Torque wrench 6
- Installation instruction on the outdoor part of the fresh air device 7
- Outdoor unit 7
- Purging method 7
- Check for installation and test run 8
- Check items for test run 8
- Correct incorrect 8
- Cutting and flaring work of piping 8
- Flare tooling die 8
- On drainage 8
- Pipe cutting is carried out with a pipe cutter and burs must be removed after inserting the flare nut flaring work is carried out 8
- Please install the drain hose so as to be downward slope without fail please don t do the drainage as shown below 8
- Please kindly explain to our customers how to operate through the instruction manual 8
- Please pour water in the drain pan of the indoor unit and confirm that drainage is carried out surely to outdoor in case that the attached drain hose is in a room please apply heat insulation to it without fail 8
- Power source installation 8
- The power source must be exclusively used for air conditioner over i0a in the case of installing an air conditioner in a moist place please install an earth leakage breaker for installation in other places use a circuit breaker as far as possible 8
Похожие устройства
- Haier HSU-12H03/V(ZXF) Инструкция по эксплуатации
- Haier HSU-24C03/V(ZXF) Инструкция по эксплуатации
- Haier HSU-24H03/V(ZXF) Инструкция по эксплуатации
- Haier HSU-18C03/V(ZXF) Инструкция по эксплуатации
- Haier HSU-22C03/V(ZXF) Инструкция по эксплуатации
- Haier HSU-22C03/V(ZXF) Инструкция по монтажу
- Haier HSU-22C03/V(ZXF) Технические данные
- Haier HSU-22C03/V(ZXF) Сервис мануал
- Haier HSU-18C03/V(ZXF) Инструкция по монтажу
- Haier HSU-18C03/V(ZXF) Технические данные
- Haier HSU-18C03/V(ZXF) Сервис мануал
- Haier HSU-22C03/V(ZF) Инструкция по эксплуатации
- Haier HSU-22H03/V(ZF) Инструкция по эксплуатации
- Haier HSU-24C03/V(ZF) Инструкция по эксплуатации
- Haier HSU-24H03/V(ZF) Инструкция по эксплуатации
- Haier HCFU-18CF03 Руководство по эксплуатации
- Haier HCFU-18CF03 Сервис мануал
- Haier HCFU-18CF03 Руководство по монтажу
- Haier HCFU-18HF03 Инструкция по монтажу
- Haier HCFU-18HF03 Руководство по эксплуатации