Haier AC282AFEAA [4/31] Cautions
![Haier AC602AFEAA [4/31] Cautions](/views2/1808123/page4/bg4.png)
2
Cautions
If the air conditioner is used under higher
temperature condition than those listed,
the built-in protection circuit may operate
to prevent internal circuit damage. Also,
during Cooling and Dry modes, if the unit
is used under conditions of lower
temperature than those listed above, the
heat-exchanger may freeze, leading to
water leakage and other damage.
Do not use this unit for any other purposes
except for the Cooling and the Heating,
Dehumidifying, and air-circulation of
rooms should be in ordinary dwellings.
The wiring method should be in line with
the local wiring standand.
The waste battery should be disposed
properly.
If the fuse on PC board is broken, please
change it with the type T 3.15A/250VAC.
The air breaker should be all-pole switch.
and the distance between it's two contacts
should no less than 3mm.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -15
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
*ERA :
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 10
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
*EAA :
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Temperature and Humidity Range
For this model, the all-pole discon-rexion
connection method should be applied in
the power supply.
Such means for disconnection must be
incorporation in the fixed wiring.
Specifications
The refrigerating circuit is leak-proof.
When the indoor unit is turned on,the
PCB will test if swing motor is O.K.,and
then fan motor will start up.So there is a
few seconds to wait .
In cooling mode,the flaps will swing
automatically to a fixed position for anti-
condensating.
Содержание
- Convertible type air conditioner 1
- Operation installation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Danger 5
- Safety precautions 5
- Warning 5
- Safety precautions 6
- Warning 6
- Automatic operation 7
- Cooling type 7
- Features and functions 7
- Heat cool type 7
- Mildew resistant filter 7
- Wireless remote control unit 7
- Cool dehumidification fan 8
- Each time the button is pressed the air direction range will change as follows 8
- Features and functions 8
- Horizontal air direction adjustment 8
- Press the air flow direction horizontal set button 8
- Press the air flow direction vertical set button 8
- The vertical airflow direction is set automatically as shown in accordance with the type of operation selected 8
- Use the air direction adjustment within the ranges shown above 8
- Use the air direction adjustments within the ranges shown above 8
- Vertical air direction adjustment 8
- Air direction louvers 9
- Air flow direction set range of swing 9
- All range 9
- Each time the button is pressed the air direction range will change as follows 9
- Features and functions 9
- Note when being switched on firstly the up down flap will be at the position of max angle in cooling the up down louver is not good to stay at position 4 5 for along time otherwise the dew will occur 9
- Right left 9
- The swing range of up down flap is as follow 9
- For series 282 362 422 482 522 602 10
- Name of parts 10
- Note for the wired control type unit the unit state should be checked by the the wired controller instead of the remote receiver and if you set the timer function the timer led on the remote receiver will not be on 10
- Cleaning and care 11
- The following four procedures are for series 282 362 422 482 522 602 11
- Mark parts name 12
- Operation tips 12
- Standard parts 12
- Caution 13
- Installation of indoor unit 13
- Location 13
- Operating noise 13
- Warning 13
- Wiring 13
- Caution 14
- For authorized service personnel only 14
- Installation of indoor unit 14
- Selecting the mounting position 14
- Warning 14
- 1 install the indoor unit level on a strong wall which is not subject to vibration 15
- 2 the inlet and outlet ports should not be obstructed the air should be able to blow all over the room 3 do not install the unit where it will be exposed to direct sunlight 15
- 4 install the unit where connection to the outdoor unit is easy 5 install the unit where the drain pipe can be easily installed 15
- 6 take servicing etc into consideration and leave the spaces shown in fig or 2 also install the unit where the filter can be removed 15
- For half concealed installation 15
- Indoor unit 15
- Installation of indoor unit 15
- 1 remove the air filters 16
- 2 remove the intake grilles 3 remove the side cover a right and left side 4 this air conditioner can be set up to intake fresh air for information about how to install for fresh air intake refer to page 22 fresh air intake 16
- Connection pipe requirement 16
- Install the room air conditioner as follows 16
- Installation of indoor unit 16
- Installation procedure 16
- Supension bolt pitch should be as shown in fig 16
- Installation of indoor unit 17
- 2 fasten the indoor unit into place by tightening up the special b blots and the m10 nuts make sure that unit is secure and willl not shift back and forth 18
- Caution 18
- In order to check the drainage be sure to use a level during installation of the indoor unit if the installation site of the indoor unit is not level water leskage may occur 18
- Installation of indoor unit 18
- When installing the indoor unit in a semi concesled orientation make sure to reinforce the insulation of the unit on all sides drops of water may fall from the unit if it is not thoroughly insulated 18
- Installation of indoor unit 19
- Installing the coupler heat insulation 19
- Notice 19
- Drain piping 20
- Installation of indoor unit 20
- 1 install insulation for the drain pipe see fig 2 and 13 cut the included insulation material to an appropriate size and adhere it to the pipe 21
- 2 if right rear piping fasten the drain pipe with vt wires so that the pipe slopes correctly within the indoor unit 21
- Installation of indoor unit 21
- 1 cut the wire and with a wire cutter or wire cutting pliers then strip the insulation to about 15 16 25mm of expose the solid wire 2 using a screwdriver remove the terminal screw s on the terminal board 3 using pliers bend the solid wire to form a loop suitable for the terminal screw 22
- 1 cut the wire and with a wire cutter or wire cutting pliers then strip the insulation to about 3 8 10mm of expose the solid wire 2 using a screwdriver remove the terminal screw s on the terminal board 22
- A for solid core wiring or f cable 22
- After passing the connection cord and power cable through the insulation tube fasten it with the cord clamp as shown in fig 5 22
- B for strand wiring 22
- B strand wire 22
- Electrical wiring 22
- How to connect wiring to the terminals 22
- How to fixed connection cord and power cable at the cord clamp 22
- Installation of indoor unit 22
- 1 match the terminal block numbers and connection cord colors with those of the outdoor unit erroneous wiring may cause burning of the electric parts 23
- 2 connect the connection cords firmly to the terminal block imperfect installation may cause a fire 23
- 3 always fasten the outside covering of the connection cord with the cord clamp if the insulator is chafed electric leakage may occur 23
- 4 always connect the ground wire 23
- Caution 23
- Electrical requirement electric wire size and fuse capacity 23
- Installation of indoor unit 23
- Select wire sizes and circuit protection from table below this table shows 20 m length wires with less than 2 voltage drop 23
- Installation of indoor unit 24
- Installation of indoor unit 25
- N 1 2 3 25
- Warning 25
- Caution 26
- Check items 26
- Customer guidance 26
- Installation of indoor unit 26
- Test running 26
- Followings are not problems 27
- Trouble shooting 27
- Air conditioner won t start 28
- Before ask for services please first check your unit against the following 28
- Poor cooling 28
- Poor cooling or heating 28
- Trouble shooting 28
- Error display for era series 29
- Remarks 29
- Resumable if lower than 100 degree 29
- Shows resumable fault shows it is not resumable fault 29
- Trouble shooting 29
- Error display for eaa series 30
- Remarks 30
- Shows resumable fault shows it is not resumable fault 30
- Trouble shooting 30
Похожие устройства
- Haier AC282AFEAA Инструкция по эксплуатации
- Haier AC282AFEAA Руководство по эксплуатации
- Haier AC282AFEAA Сервис мануал
- Haier AC282AFEAA Технические данные
- Haier AC362AFEAA Инструкция по монтажу
- Haier AC362AFEAA Инструкция по эксплуатации
- Haier AC362AFEAA Руководство по эксплуатации
- Haier AC362AFEAA Сервис мануал
- Haier AC362AFEAA Технические данные
- Haier AC602AFEAA Инструкция по монтажу
- Haier AC602AFEAA Инструкция по эксплуатации
- Haier AC602AFEAA Сервис мануал
- Haier AC602AFEAA Руководство по эксплуатации
- Haier AC602AFEAA Технические данные
- Haier AC482AFEAA Инструкция по монтажу
- Haier AC482AFEAA Инструкция по эксплуатации
- Haier AC482AFEAA Руководство по эксплуатации
- Haier AC482AFEAA Сервис мануал
- Haier AC482AFEAA Технические данные
- Haier AC282AFERA Инструкция по монтажу