Haier AP482AKEAA [7/30] Operation
![Haier AP602AKEAA [7/30] Operation](/views2/1808422/page7/bg7.png)
5
1
2
3
Operation
Clock set
Press CLOCK button, "AM"or "PM" flashes.
Press or to set correct time. Each press will increase
or decrease 1 min . If the button is kept pressed, time will
change quickly.
After time setting is confirmed, press SET, "AM" and "PM"
stop flashing, while clock starts working.
Remote controller's operation
When in use, put the signal transmission
head directly to the receiver hole on the
indoor unit
The distance between the signal transmission
head and the receiver hole should be within
7m without any obsacles as well.
Don't throw the controller, prevent it from
being damaged.
When electronic-started type fluorescent
lamp or change-over type fluorescent lamp
or wireless telephone is installed in the room,
the receiver is apt to be disturbed in receiving
the signal so the distance to the indoor unit
should be shorter.
2R-03 dry batteries
MINUTES
MODE
SLEEP
SWING
CLOCK
TIMER
SET
LOCK
LIGHT
RESET
HEAT
1
2
3
Confirmation indicator:
In disorderation, reload the batteries or load the new batteries
after 5 mins.
Note:The waster batteries should be disposed properly,use two
new same-type batteries when loading.
If the remote controller can’t function normally or doesn’t work at
all,use a sharp-pointed item to press the reset key.
Hint:Remove the batteries in case unit won’t be in usage for a long period.
If there are any displays after taking-out just need to press reset key.
When throw away the waste batteries, please perform in accordance with the local regulation.
Loading of the battery
Slightly press " " and push down the cover.
Load the batteries as illustrated.
2 R-03 dry batteries, (cylinder)
Be sure that the loading is in line with the "+"/"-" pole
request as illustrated.
Put on the cover again.
When unit is started for the first time
and after replacing batteries in remote
controller, clock should be adjusted as follows:
Содержание
- Ap482akeaa ap602akeaa 1
- Cabinet type air conditioner 1
- No 010578212 1
- Operation installation manual 1
- Content 2
- Operation 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Cautions 4
- I n d o o r u n i t 5
- Inlet grill outlet grill 5
- Outdoor unit 5
- Outlet grill operation panel inlet grill air filter inside the unit 5
- Remote controller 5
- For cooling only unit there is no functions related to heat 6
- Manual operation 6
- Note these models don t have the following related display and function for some air conditioners the function is not availed 6
- Clock set 7
- Confirmation indicator 7
- Loading of the battery 7
- Operation 7
- Remote controller s operation 7
- C higher than temp setting unit will run intermittently at low speed regardless of fan setting 8
- Control panel 8
- In dry mode when room temp becomes 2 8
- Operation 8
- Remote control unit 8
- About fan mode 9
- Adjust fan speed 9
- Control panel 9
- Fan operation 9
- Fan or to set temperature 9
- Low med high 9
- Manual operation 9
- Mode it is not possible to select auto 9
- Operation 9
- Remote controller 9
- Select operating mode 9
- Unit start 9
- Unit stop 9
- When the air conditioner runs in fan 9
- Air flow adjustment 10
- Left right air direction 10
- Operation 10
- Swing louver 10
- Up down air direction 10
- Control panel 11
- Operation 11
- Remote controller 11
- Sleep function 11
- Use of sleep function 11
- Cancel timer mode 12
- Confirm setting 12
- Control panel 12
- Manual operation 12
- Operation 12
- Remote controller 12
- Timer mode selection 12
- Timer on off function 12
- Timer setting press time adjust buttons 12
- Unit start 12
- Canel timer mode 13
- Control panel 13
- Manual operation 13
- Operation 13
- Remote controller 13
- Set clock correctly before starting timer operation 13
- Time confirming for timer off 13
- Time setting for timer on 13
- Timer confirming for timer on 13
- Timer mode selection 13
- Timer on off function 13
- Timer setting for timer off 13
- Unit start 13
- Control panel 14
- Control panel display 14
- Control panel display control 14
- Display function 14
- Lcd color control 14
- Operation 14
- Cold draft prevention 15
- Defrosting 15
- Fan speed changes 15
- Min delay protection 15
- Operation hints 15
- Unit operation 15
- Use objectively 15
- Energy saving 16
- On off 16
- Air filter cleaning 17
- Maintenance 17
- After season maintenance 18
- Before season maintenance 18
- Indoor and outdoor cleaning 18
- Maintenance 18
- Followings are not problems 19
- Trouble shooting 19
- Air conditioner won t start 20
- Before asking services please firstly check your unit according to following 20
- Poor cooling 20
- Poor cooling or heating 20
- When problems occur 20
- Air conditioner must use an exclusive line over 30a when installation air conditioner in a wet place try to use a circuit breaker against current leakage for installation in other places use circuit breaker as far as possible 21
- Ap482akeaa 21
- Ap602akeaa 21
- Charge over switch 21
- Errors display 21
- H07rn f 5g 2 m 21
- H07rn f 5g 4 m 21
- Power supply 21
- Such means for disconnection must be incorporation in the fixed wiring 21
- The breaker of the air conditioner should be all pole switch and the distance between its two contacts should be no less than 3 mm 21
- The power cable should be over 21
- Use copper wire only the parameter of connecting cable is h05rn f 4g 0 5m 21
- When problems occur 21
- Bottom 22
- Indoor outdoor unit connection 22
- On off 22
- Over 10cm 22
- Pipe direction 22
- Temp health 22
- Standard accessories 23
- Tools necessary 23
- Delivery 24
- Display of whole unit 24
- Facing up 24
- Installation of outdoor unit 24
- Installation procedures 24
- Cross section of wall hole 25
- Fixing of indoor unit 25
- Fixing of the unit 25
- Indoor side 25
- Installation of indoor unit 25
- Installation procedures 25
- Wall hole wall thickness 25
- After opening inlet grill you will see a control box as shown in the fig remove the cover before wiring work 26
- Arrangement of piping and drainage pipe 26
- Connecting electric cable for indoor and outdoor unit 26
- Copper tube 26
- Cut away with a hammer or a saw the lid for piping according to piping direction 26
- Drain hose 26
- Installation procedures 26
- Insulation material 26
- Piping connection 26
- Piping connection of indoor unit 26
- Down bad 27
- If humidity is high drain pipe especially in room and indoor unit must be covered with insulation material 27
- Indoor unit 27
- Installation procedures 27
- Piping connection of outdoor unit connect the connecting pipe and inlet and outlet liquid pipe according to the piping method 27
- Purging method 27
- Slope good 27
- Electric wiring 28
- Installation procedures 28
- A flaring tool 29
- Correct 29
- Incorrect 29
- Lean damaged flare crack partial too outside 29
- Others 29
Похожие устройства
- Haier AP602AKEAA Руководство по эксплуатации
- Haier AP602AKEAA Сервис мануал
- Haier AP602AKEAA Технические данные
- Haier AS182AVERA Инструкция по монтажу
- Haier AS182AVERA Сервис мануал
- Haier AS182AVERA Технические данные
- Haier AU36NAHERA Инструкция по монтажу
- Haier AU422AIERA Инструкция по монтажу
- Haier AU42NAIERA Инструкция по монтажу
- Haier AU522AIERA Инструкция по монтажу
- Haier AU52NAIERA Инструкция по монтажу
- Haier AC422AFERA Инструкция по эксплуатации
- Haier AC522AFERA Инструкция по эксплуатации
- Haier AU142AAERA Инструкция по монтажу
- Haier AD09LS1ERA Руководство по эксплуатации
- Haier AD09LS1ERA Сервис мануал
- Haier AD12LS1ERA Руководство по эксплуатации
- Haier AD12LS1ERA Сервис мануал
- Haier AD18LS1ERA Руководство по эксплуатации
- Haier AD24LS1ERA Руководство по эксплуатации