Haier AU42NAIERA [7/26] Safety cautions
![Haier AU42NAIERA [7/26] Safety cautions](/views2/1808079/page7/bg7.png)
Safety Cautions
In the event of a refrigerant gas leak,
provide adequate ventilation to the room.
Do not touch the fins on the heat exchanger
with bare hands:they are sharp and
dangerous.
If leaked refrigerant gas is exposed to a heat
source, noxious gases may form.
Direct expesure to outdoor air may present a
health hazard, and it may also cause food items
to deteriorate.
Do not try to defeat the safety features of
the devices, and do not change the settings.
Defeating the safety features on the unit such as
the pressure switch and temperature switch or
using parts other than the dealer or specialist
may result in fire or explosion.
When installing the unit in a small room,
safeguard against hypoxia that results from
leaked refrigerant reaching the threshold
level.
When relocating the air conditioner,
consult the dealer or a specialist.
Consult the dealer for necessary measures to take.
Improper installation may result in water leak,
electric shock, or fire.
After completing the service work, check
for a refrigerant gas leak.
If leaked gas refrigerant is exposed to a heat
source such as fan heater,stove,and electric grill,
noxious gases may form.
Only use specified parts.
Have the unit professionally installed.
Improper installation may cause water leak,
electric shock,smoke, or fire.
Precautions for handling Units for Use with R410A
Caution!
Do not use the existing refrigerant piping
The old refrigerant and refrigerator oil in the
existing piping contain a large amount of
chlorine, which will cause the refrigerator oil in
the new unit to deteriorate.
R410A is a high-pressure refrigerant,and the use
of the existing piping may result in bursting.
Keep the inner and outer surfaces of the
pipes clean and free of contaminants such
as sulfur, oxides, dust/dirt shaving particles,
oils,and moisture.
Contaminants inside the refrigerant piping will
cause the refrigerant oil to deteriorate.
Do not use the following tools that have
been used with the conventional
refrigerants. prepare tools that are for
exclusive use with R410A.
(Gauge manifold, charging hose, gas leak
detector,reverse-flow check valve,
refrigerant charge base,vacuum gauge,
and refrigerant recovery equipment.)
If refrigerant and/or refrigerant oil left on these
tools are mixed in with R410, or if water is
mixed with R410A, it will cause the refrigerant
to deteriorate.
Since R410A does not contain chlorine, gas-leak
detectors for conventional refrigerators will not
work.
With All-Fresh type air cinditioners, outdoor
air may be directly blown into the room
upon thermo off. Take this into consideration
when installing the unit.
Use a vacuum pump with a reverse-flow-
check valve.
If other types of valves are used, the vacuum
pump oil will flow back into the refrigerant cycle
and cause the refrigerator oil to deteriorate.
Warning !
5
Содержание
- Dc inverter 1
- Installation instructions 1
- Outdoor unit 1
- Room air conditioner 1
- Name of parts 3
- Carefully read the following information in order to operate the air conditioner correctly 4
- Instructions 4
- Safety cautions 4
- Symbols used in the illustrations 4
- Warning 4
- Warning caution 4
- Safety cautions 5
- Warning 5
- Have the unit professionally installed 6
- Safety cautions 6
- Warning 6
- Caution 7
- Precautions for handling units for use with r410a 7
- Safety cautions 7
- Warning 7
- Before installing the unit 8
- Caution 8
- Safety cautions 8
- Warning 8
- Before installing relocating the unit or performing electric work 9
- Before the test run 9
- Caution 9
- Do not operate switches with wet hands to avoid electric 9
- Ground the unit 9
- Safety cautions 9
- Caution 10
- Items to be checked 10
- Necessary tools and materials 10
- Read before installation 10
- Piping materials 11
- Read before installation 11
- Tool and materials that must not used with r410a 11
- Tools and materials that are used with r22 or r407c that can also be used with r410a 11
- Tools and materials that may be used with r410 with some restrictions 11
- Tools for r410a must be handled with special care keep moisture and dust from entering the cycle 11
- Read before installation 12
- Airtightness test 13
- Items to be strictly observed 13
- Read before installation 13
- Reasons 13
- Vacuuming 13
- Characteristics of the conventional and the new refrigerants 14
- Charging refrigerant 14
- Read before installation 14
- Reasons 14
- Remedies to be taken in case of a refrigerant leak 14
- Accessories 15
- Installation procedure 15
- Selection of the place of installation 15
- Anchor bolt 16
- Au122aeera 16
- Au182afera 16
- Concrete foundation 16
- Installation of outdoor unit 16
- Installation procedure 16
- Au242agera 17
- Au282ahera au362ahera au36nahera 17
- Installation of outdoor unit 17
- Installation procedure 17
- Installation of outdoor unit 18
- Installation procedure 18
- Refrigerant piping 18
- 2 piping size 19
- 3 limitations for one way piping length and vertical height difference 19
- 4 piping connection 19
- Installation procedure 19
- Refrigerant piping 19
- Air discharging method 20
- Check if the pressure drops 20
- Installation procedure 20
- Charging amount of refrigerant 21
- Installation procedure 21
- Piping method to use wacuum pump e g au182afera 21
- Refrigerant piping 21
- Electric wiring 22
- Installation procedure 22
- Caution 23
- Installation procedure 23
- Test run 23
- Warning 23
- Electric wiring 24
- Installation procedure 24
- Trouble display 24
Похожие устройства
- Haier AU522AIERA Инструкция по монтажу
- Haier AU52NAIERA Инструкция по монтажу
- Haier AC422AFERA Инструкция по эксплуатации
- Haier AC522AFERA Инструкция по эксплуатации
- Haier AU142AAERA Инструкция по монтажу
- Haier AD09LS1ERA Руководство по эксплуатации
- Haier AD09LS1ERA Сервис мануал
- Haier AD12LS1ERA Руководство по эксплуатации
- Haier AD12LS1ERA Сервис мануал
- Haier AD18LS1ERA Руководство по эксплуатации
- Haier AD24LS1ERA Руководство по эксплуатации
- Haier AD18LS1ERA Сервис мануал
- Haier AC18CS1ERA(S) Сервис мануал
- Haier AC24CS1ERA(S) Сервис мануал
- Haier 3U19FS1ERA Сервис мануал
- Haier 4U25HS1ERA Сервис мануал
- Haier 4U25HS1ERA Инструкция по монтажу
- Haier 4U30HS1ERA Сервис мануал
- Haier 5U34HS1ERA Сервис мануал
- Haier AD842AHEAA Инструкция по монтажу