5.1.4 Refrigerant piping
HBU-18HF03 HDU-18CF03 HDU-18HF03
Outdoor
unit
Gas pipe
Liquid
pipe
Flare connection
Indoor
unit
3-way stop valve
3-way stop valve
HDU-42HF03/H
HDU-28CF03 HDU-28HF03 HBU-28HF03
Piping size
Install the removed flare nuts to
the pipes to be connected, then
flare the pipes.
90+0.5
Gas pipe
Liquid pipe
Gas pipe
6.35x0.8mm
12.7x1.0mm
9.52x0.8mm
15.88x1.0mm
Liquid pipe
HDU-28HF03
HBU-18HF03
HDU-18CF03
HDU-18HF03
HDU-28CF03
Gas pipe
Liquid pipe
Gas pipe
9.52x0.8mm
15.88x1.0mm
9.52x0.8mm
19.05x1.0mm
Liquid pipe
HBU-42HF03
HBU-28CF03
HBU-28HF03
HDU-42HF03/H
Limitations for one way piping length and vertical height difference.
HDU-28HF03
Model
One way piping length
Vertical height difference
(between indoor and outdoor)
HBU-18HF03 HDU-18HF03
less than 15 m
less than 5 m
less than 40 m
less than 15 m
HDU-28CF03
HDU-18CF03
HBU-28CF03 HBU-28HF03
HBU-42HF03
HDU-42HF03/H
less than 50 m
less than 30 m
HBU-28CF03 HDU-28CF03