Haier HBU-42HI03 [16/129] Commercial air conditioner

Haier HBU-42CI03, [16/129] Commercial air conditioner
Commercial Air Conditioner Model: HBU-18/28/42HF03
HBU-28CF03 HDU-18/28CF03
HDU-18/28HF03 HDU-42HF03/H
16
Function
coolin
g
heatin
g
Capacity BTU/h
42600 47700
Capacity kW
12.5 14
Sensible heat ratio
75% /
W
4900 4900
W
6100 5800
EER or COP
W/W
2.55 2.86
Dehumidifying capacity
10ϋ³×m³/h
Power cable section
Signal cable section
Connecting cable section
Wired control cable for wired control unit section
/ 4×0.33mm² shield wire
Power source N, V, Hz
A / A
Start Current A
Class of anti electric shock
ǂǂI ǂǂI
Circuit breaker A
/30
Max. operating pressure of heat side Mpa
Max. operating pressure of cold side Mpa
Unit model (color)
Type × Number
Speed(H-M-L) r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Total Area
Temp. scope
ć
External
˄L×W×H˅
mm×mm×mm
Package
˄L×W×H˅
mm×mm×mm
Air sending angle
//
Drainage pipe (material , I.D./O.D.) mm
Control type (Remote /wired /model)
Fresh air hole dimension mm
Outlet distribution hole dimension mm
kW
dB(A)
kg / kg
External
˄L×W×H˅
mm×mm×mm
Package
˄L×W×H˅
mm×mm×mm
kg / kg
Unit model (color)
Model / Manufacture
Oil model
Oil type
Oil charging
Type
Protection type
Starting method
Type × Number
Speed r/min
Fan motor output power kW
Air-flow(H-M-L) m³/h
Type / Diameter mm
Row / Fin pitch
Temp. scope
ć
External
˄L×W×H˅
mm×mm×mm
Package
˄L×W×H˅
mm×mm×mm
Drainage pipe (material , I.D./O.D.) mm
Refrigerant control method mm/mm
Volume of Accumulator L
Noise level dB(A)
material of reduce noise
crankcase heater power W
kg / kg
Type / Charge g
Recharge quantity g/m
Liquid mm
Gas mm
Connecting Method
m
m
6×0.75mm2
ǂ4GSD/SAY56T
/
1700
2.8
2.8
Fan
Heat exchanger
Fan
Dimension
Compressor
/
Capillary tube
Refrigerant
/
/
55/52/47
/
64
840±50
SCROLL
/
Axial × 1
C-SB373H8F SANYO
/
/
Inner thermal protection
hard startup
Type of Four way valve
/
/
Defrosting
Automatic
/
MAX.Pi
p
in
g
len
g
th 50
Weight (Net / Shipping)
106
/111
PIPING
R22/4200
/
Pipe
9.52
19.05
Flared
Between I.D &O.D
MAX.Drop 30
Dimension
1250×340×948
1350×410×1090
/
cooling: 43~60 / heating: 6~7
Heat exchanger
TP2M / 9.52x0.36
Running /Max.Running current
Centrifugal × 1
0.016
6000
/
Outdoor unit
HDU-42HF03/H
(
OUTDOOR
)
˄WHITE˅
Weight (Net / Shipping)
62/77
Panel
item Model
HDU-42HF03/H
5.0
5×2.5mm2
Total power input
Max. power input
/
Weight (Net / Shipping)
1560-2580
Dimension
/
cooling: 43~60 heating:6~7
1385×965×418
/
1197×828×355
ǂWIRED
0.27
Norminal condition: indoor temperature (cooling): 27 ćDB/19ćWB, indoor temperature (heating): 20 ćDB
Outdoor temperature(cooling): 35ćDB/24ćWB, outdoor temperature(heating): 7 ćDB/6ćWB
The noise level will be measured in the third octave band limited values, using a Real Time Analyser calibrated sound intensity meter. It is a sound pressure noise level. The detailed
method please refer to the following information:
1070±30/860±40/690±50
3ˈ380-400ˈ50
Indoor unit
HDU-42HF03/H(INDOOR)˄WHITE˅
Noise level (H-M-L)
Electricity Heater
cooling 8.0/12.0 heating8.2/10.5
50