Haier HSU-09H03/R(QXF) [5/109] Cautions regarding products after repair
![Haier HSU-12H03/R(QXF) [5/109] Cautions regarding products after repair](/views2/1809716/page5/bg5.png)
HSU-09,12H03/R(QXF) Introduction
2
Domestic Air Conditioner
Warning
Do not repair the electrical components with wet hands. Working on the equipment with wet hands can
cause an electrical shock.
Do not clean the air conditioner by splashing water. Washing the unit with water can cause an electrical
shock.
Be sure to provide the grounding when repairing the equipment in a humid or wet place, to avoid electrical
shocks.
Be sure to turn off the power switch and unplug the power cable when cleaning the equipment. The
internal fan rotates at a high speed, and cause injury.
Do not tilt the unit when removing it. The water inside the unit can spill and wet the furniture and floor.
Be sure to check that the refrigerating cycle section has cooled down sufficiently before conducting repair
work. Working on the unit when the refrigerating cycle section is hot can cause burns.
Use the welder in a well-ventilated place. Using the welder in an enclosed room can cause oxygen
deficiency.
1.1.2 Cautions Regarding Products after Repair
Warning
Be sure to use parts listed in the service parts list of the applicable model and appropriate tools to
conduct repair work. Never attempt to modify the equipment. The use of inappropriate parts or tools can
cause an electrical shock, excessive heat generation or fire.
When relocating the equipment, make sure that the new installation site has sufficient strength to
withstand the weight of the equipment.
If the installation site does not have sufficient strength and if the installation work is not conducted
securely, the equipment can fall and cause injury.
Be sure to install the product correctly by using the provided standard installation frame.
Incorrect use of the installation frame and improper installation can cause the equipment to fall, resulting
in injury.
For
integral
units only
Be sure to install the product securely in the installation frame mounted on a window frame.
If the unit is not securely mounted, it can fall and cause injury.
For
integral
units only
Содержание
- Caution in repair 4
- Introduction 4
- Safety cautions 4
- Warning 4
- Cautions regarding products after repair 5
- Domestic air conditioner 5
- Hsu 09 12h03 r qxf introduction 5
- Warning 5
- Caution 6
- Domestic air conditioner 6
- Hsu 09 12h03 r qxf introduction 6
- Warning 6
- Caution 7
- Domestic air conditioner 7
- Hsu 09 12h03 r qxf introduction 7
- Inspection after repair 7
- Warning 7
- Domestic air conditioner 8
- Hsu 09 12h03 r qxf introduction 8
- Icon type of information description 8
- Icons are used to attract the attention of the reader to specific information the meaning of each icon is described in 8
- The table below 8
- Using icons 8
- Using icons list 8
- Functions and control 14
- Main functions and control specifications 14
- Minutes 16
- Hours t 1 hour ts 2 ts 1 1 hours 17
- Off t hour 17
- T ts 3hours 3hours ts 2 ts 3 ts 4 1 hour 17
- Timer function 18
- Function of main thermistor 19
- B25 50 4200k 3 20
- Domestic air conditioner 20
- Indoor unit 20
- R25 23k 3 20
- Room sensor 20
- Value of thermistor 20
- Domestic air conditioner 21
- Hsu 09 12h03 r qxf funtions and control 21
- Domestic air conditioner 22
- Hsu 09 12h03 r qxf funtions and control 22
- Domestic air conditioner 23
- Hsu 09 12h03 r qxf funtions and control 23
- B25 50 3700k 3 24
- Domestic air conditioner 24
- Hsu 09 12h03 r qxf funtions and control 24
- Pipe sensor 24
- R25 10k 3 24
- Domestic air conditioner 25
- Hsu 09 12h03 r qxf funtions and control 25
- Domestic air conditioner 26
- Hsu 09 12h03 r qxf funtions and control 26
- Domestic air conditioner 27
- Hsu 09 12h03 r qxf funtions and control 27
- System configuration 28
- Cautions 29
- Contain no fluorochloric hydrocarbon 29
- Disposal of the old air conditioner 29
- Disposal of the packaging of your new air conditioner 29
- Instruction 29
- Safety instructions and warnings 29
- Cautions 30
- Specifications 30
- The machine is adaptive in following situation 30
- Caution 31
- Cautions 31
- Installation 31
- Safety instruction 31
- Warning 31
- Caution 32
- Cautions 32
- Domestic air conditioner 32
- Hsu 09 12h03 r qxf system configuration 32
- Warning 32
- Indoor unit 33
- Outdoor unit 33
- Parts and functions 33
- Emergency and test operation 46
- Emergency operation 46
- Operation 46
- Removal of the restriction of emergency or test operation 46
- Test operation 46
- For smart use of the air conditioner 47
- Maintenance 47
- Air filter cleaning 48
- Attach the filter 48
- Clean the filter 48
- Close the inlet grille 48
- Do not use the following for cleaning 48
- For smart use of the air conditioner 48
- Indoor body 48
- Maintenance 48
- Open the inlet grille by pulling it upward 48
- Remote controller 48
- Remove the filter 48
- Warning 48
- Maintenance 50
- To keep your air conditioner in good condition after season 50
- Before setting in high season 51
- Caution 51
- Cleaning the standard air filter 51
- Connecting the earthing cable 51
- Do not block the air inlet or outlet 51
- Earthing 51
- Maintenance 51
- No wet hand 51
- Plug in 51
- Before asking for service check the following first 52
- Trouble shooting 52
- Fresh air pipe 1 full energy recovery exchanger 66
- Packing list 66
- Refresh system installation 66
- Bend connector 67
- Full energy recovery exchanger 67
- Room air pipe 67
- According to the drawing install the full energy recovery exchanger on 68
- Installation manual 68
- Outdoor unit cover with the screws 68
- The corresponding place of the outdoor unit and fix the fittings on the 68
- The main unit installation 68
- Pipeline installation 69
- Small size outdoor unit installation sketch 69
- Caution 70
- Power block installation 70
- Indoor unit 71
- Installation of indoor unit 71
- 5 drain pan 81
- 0 outdoor panel 94
- Appendix 104
- Cooling 104
- Heating 104
- Hsu 09 12h03 r qxf appendix 104
- Piping diagrams 104
- Hsu 09 12h03 r qxf appendix 105
- Indoor 105
- Wiring diagrams 105
- Circuit diagram 107
- Circuit diagram 1 107
- Circuit diagram 2 108
- Hsu 09 12h03 r qxf appendix 108
Похожие устройства
- Haier HSU-12H03/R(QXF) Руководство по эксплуатации
- Haier HSU-12H03/R(QXF) Сервис мануал
- Sc&t HKM02BT Инструкция по эксплуатации
- Sc&t HKM02BR Инструкция по эксплуатации
- Sc&t HKM02BT-4K Инструкция по эксплуатации
- Sc&t HKM02BR-4K Инструкция по эксплуатации
- Sc&t HKM02BPT-4K Инструкция по эксплуатации
- Sc&t HKM02BPR-4K Инструкция по эксплуатации
- Sc&t HE01SER Инструкция по эксплуатации
- Sc&t HE01ERK Инструкция по эксплуатации
- Sc&t HE01ST Инструкция по эксплуатации
- Sc&t HE01SR Инструкция по эксплуатации
- Sc&t HW01 Инструкция по эксплуатации
- Sc&t HE01SI Инструкция по эксплуатации
- Sc&t HE01S Инструкция по эксплуатации
- Sc&t HKM01E Инструкция по эксплуатации
- Sc&t HE03 Инструкция по эксплуатации
- Sc&t HE02EI Инструкция по эксплуатации
- Sc&t HE02EIP Инструкция по эксплуатации
- Sc&t HE02EIX Инструкция по эксплуатации