INSTALLATION
PAGE 2
ENGLISH
Step 1 - Preparation
Required Tools for Installation
Procedure for Selecting the Location
detector
Note:
place.
Clearances of Indoor and Outdoor Units
F
A
C
E
D
Floor xing dimensions of the outdoor unit
Fixing of outdoor unit
Fix the unit to concrete or block
with bolts
(10mm) securely.
When
tting the unit to wall
surface, roof or
rooftop,
x the unit securely in consideration
of
earthquake and strong wind.
If vibration may affect the
house, x the unit
by attaching a
vibration-proof mat.
The marks from to
in the
gure are the
name of he parts.
The distance between
the indoor unit and the
oor should be more
than 6 feet.
The models adopt HFC free refrigerant R410A
more han
4in.
more than 4in.
more han 4in.
more than 4in.
more than 4in.
more than 24in.
more than 6in.
A
G
Arrangement of piping
directions
Rear left
Left
Rear
right
Right
Below
G
Attention must be paid to
the pitch of drain hose
Z
Dimensions(inches)
Model
(Unit: inch)
5 1/2”
4 1/2”
5 1/8” 19 5/8” 5 7/8” 12 1/2”
5 1/8” 24 3/4” 5 1/8” 14”
5 1/16” 26” 5 1/16” 15 3/4”
5 1/2”
4 1/2”
19 5/8”
23”
10 1/16”
12 5/8”
1U12LC2VHA
1U09TE1VHA
1U12TE1VHA
1U18LC2VHA
1U09ES2VHA
1U12ES2VHA
1U18ES2VHA
1U18TE2VHA
1U24ES2VHA
1U24TE2VHA
21
1 x2