Haier AS26TACHRA [4/28] The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover a contains fluorinated greenhouse gases covered by the kyoto protocol b factory refrigerant charge of the product see unit name plate c additional refrigerant amount charged in the field d total refrigerant charge e outdoor unit f refrigerant cylinder and manifold for charging
![Haier AS09TACHRA [4/28] The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover a contains fluorinated greenhouse gases covered by the kyoto protocol b factory refrigerant charge of the product see unit name plate c additional refrigerant amount charged in the field d total refrigerant charge e outdoor unit f refrigerant cylinder and manifold for charging](/views2/1812702/page4/bg4.png)
1
1+2=
kg
R32
2
kg
2=
1=
B
C
D
F E
kg
A
This product contains fluorinated greenhouse gases covered
by the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type: R32
GWP=global warming potential
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
The filled out label must be adhered in the proximity of the
product
charging port (e.g. onto the inside of the stop value
cover).
A contains fluorinated greenhouse gases covered by the
Kyoto
Protocol
B factory refrigerant charge of the product: see unit name
plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
CAUTION:
Tighten the flare nut according to the specified method such as with a torque wrench.If the flare nut
is too tight, it may crack after prolonged use, causing refrigerant leakage.
Do not install the air conditioner at any place where there is danger of flammable gas leakage.
In the event of a gas leakage, build-up of gas near the air conditioner may cause a fire to break out.
Take adequate steps to prevent the outdoor unit being used as a shelter by small animals.Small animals
making contact with electrical parts can cause malfunctions, smoke or fire.
Please instruct the customer to keep the area around the unit clean
The temperature of refrigerant circuit will be high, please keep the inter-unit wire away from copper pipes
that not thermally insulated.
Only qualified personnel can handle, fill, purge and dispose of the refrigerant.
2
3 GWP* value=675
tCO2=(1+2) x 3 /1000
Model
Factory charge
(
kg
)
CO2 Equivalent(t)
1U26MACFRA 0.65
HOW TO USE DRED APPLIANCE
Please consult your reseller and/or installer to determine if you have a DRED
appliance.
Connect output from your home's electricity power meter (where
(This function is unavailable on some models.)
available) to the RJ45 connector on the outdoor unit, as shown.
1U35MACFRA
1U53RACFRA
0.79
1
0.44
0.54
0.69
1U71RACFRA
1.3 0.88
Содержание
- Room air conditioner installation manual 1
- U26macfra 1u35macfra 1u53racfra 1
- U71racfra 1
- Contents 2
- Keep this manual where the user can easily find it 3
- Read the precautions in this manual carefully before operating the unit this appliance is filled with r32 3
- Warning 3
- Cautio 4
- Contains fluorinated greenhouse gases covered by the kyoto protocol 4
- How to use dred appliance 4
- Important information rega rding the refrigerant used 4
- The filled out label must be adhered in the proximity of the product charging port e g onto the inside of the stop value cover a contains fluorinated greenhouse gases covered by the kyoto protocol b factory refrigerant charge of the product see unit name plate c additional refrigerant amount charged in the field d total refrigerant charge e outdoor unit f refrigerant cylinder and manifold for charging 4
- The maximum refrigerant charge amount m 5
- Maintenance items 11
- Adhesive tape 14
- Air inlet 14
- Air outlet 14
- Compressor inside of unit 14
- Drain hose 14
- Heating insulating material 14
- Indoor outdoor unit installation drawings 14
- Non adhesive tape 14
- Optional parts for piping 14
- Piping hole cover 14
- Please be subjected to the actual product purchased 14
- Saddle l s with screws connecting electric cable for indoor and outdoor drain hose 14
- The marks from to in the gure are the parts numbers the indoor unit should be installed at the recommended height 2m 14
- When installing the unit to wall roof or rooftop fix a supporter surely with nails or wires in preparation of earthquake and strong wind 2 air conditioner mounted not above and one meter away from electric equipment such as television 14
- Hfc 410a 21
- A 110mm 22
- A 120mm 22
- A 126mm 22
- A 212mm 22
- Cushion rubber 22
- Installation dimension unit mm 22
- Caution 23
- Connection of pipes 23
- Ceramic type of ac 250v t25a 26
- Outdoor unit 27
- Australia 1300 729 948 haier com au new zealand 0800 424 372 haier co nz 28
- For haier appliances 28
Похожие устройства
- Haier AS35TBCHRA Брошюра
- Haier AS35TBCHRA Инструкция по эксплуатации
- Haier AS35TBCHRA Инструкция по монтажу
- Haier AS53TCCHRA Брошюра
- Haier AS53TCCHRA Инструкция по эксплуатации
- Haier AS53TCCHRA Инструкция по монтажу
- Haier AS71TECHRA Брошюра
- Haier AS71TECHRA Инструкция по эксплуатации
- Haier AS71TECHRA Инструкция по монтажу
- Haier 1U09MACFRA Инструкция по монтажу
- Haier 1U12MACFRA Инструкция по монтажу
- Haier 1U18RACFRA Инструкция по монтажу
- Haier 1U24RACFRA Инструкция по монтажу
- Haier 1U26MACFRA Инструкция по монтажу
- Haier 1U35MACFRA Инструкция по монтажу
- Haier 1U53RACFRA Инструкция по монтажу
- Haier 1U71RACFRA Инструкция по монтажу
- Haier AS26DCBHRA Брошюра
- Haier AS26DCBHRA Инструкция по монтажу
- Haier AS35DCBHRA Брошюра