Haier AS09BS4HRA [12/13] Check items for test run
![Haier AS09NS3HRA [12/13] Check items for test run](/views2/1812978/page12/bgc.png)
1. Insert from outside the room cable into left side of the wall
hole, in which the pipe has already existed.
2. Pull out the cable on the front side, and connect the cable
making a loop.
When connecting the cable, confirm the terminal number of indoor and
outdoor units carefully. If wiring is not correct, proper operation can not
becarriedoutandwillcausedefect.
Insertthecablefromtheback
side of the unit, then pull it out
on the front side.
Loosen the screws and insert
the cable ends fully into
terminal block, then
tighten the screws.
Pull the cable slightly to
make sure the cables have
been properly inserted and
tightened.
After the cable connection,
never fail to fasten the connected cable with the
wiring cover.
When connecting the cable after installing the indoor unit
When connecting the cable before installing the indoor unit
Note:
1. If the supply cord is damaged, it must be replaced by the manufacturer or its
service agent or a similar qualified person. The type of connecting wire is
H05RN-F
or H07RN-F.
2.IfthefuseonPCboardisbrokenpleasechangeitwiththe
type of
3.Thewiringmethodshouldbeinlinewiththelocalwiringstandard.
4. After installation, the power plugshouldbeeasilyreached.
5. A breakershouldbeincorporatedintofixedwiring.Thebreakershouldbe
all-pole
switchandthedistancebetweenitstwocontactsshouldbenotless
than 3mm.
T.3.15A/250VAC (Indoor).
To Outdoor unit
Connecting wiring
4G0.75mm
2
Thepowersourcemustbeexclusivelyusedforair
conditioner.
In the case of installing an air conditioner in a moist place,
please install
an ea
For installation in other places, use a circuit breaker as far
as possible.
Pipecuttingiscarriedoutwith a pipecutterandbursmust beremoved.
After inserting the flare nut, flaring work is carried out.
Power Source Installation
Cutting and Flaring Work of Piping
Flare tool for R410A Conventional flare tool
Clutch-type clutch-type(Rigid-type) Wing-nut type (Imperial-type)
A 0~0.5mm 1.0~1.5mm 1.5~2.0mm
rth leakage breaker.
Lean
Damage of flare Partial Too outside
tcerrocnItcerroC
On Drainage
It becomes
high midway.
The gap with the
ground is too small.
Thereisthebad
smell from a ditch
It waves.
The end is imm-
ersed in water.
Pleaseinstallthedrainhosesoastobedownwardslopewithoutfail.
Please don’t do the drainage as shown below.
Please pour water in the drain pan of the indoor unit, and
is carried out surely to outdoor.
In case that the attached drain hose is in a room, please
apply heat
insulation
to
Less than
5cm
confirm that
drainage
it without fail.
Crack
Indoor unit
CheckItemsforTestRun
Gasleakfrompipeconnecting?
Heat insulation of pipe connecting?
Are the connecting wirings of indoor and outdoor firmly
Is the connecting wiring of indoor and outdoor firmly fixed?
Is drainage securely carried out?
Is the earth line securely connected?
Istheindoorunitsecurelyfixed?
Is power source voltage abided by the code?
Is there any noise?
Isthelampnormallylighting?
Arecoolingandheating(wheninheatpump)performednormally?
Is the operation of room temperature regulator normal?
Please kindly explain to our customers how to
operate
through the instruction manual.
inserted to the terminal block?
Put check mark
in boxes
Flare tooling die
1.Cut pipe
2.Remove burs
3.Insert the
are nut
4.Flare pipe
On Drainage
Check for Installation and Test Run
Code
indication
Trouble description
Analyze and diagnose
E1
E2
E4
E7
E14
Heat-exchange
sensor failure
Indoor EEPROM
error
Communication
fault between
indoor and outdoor
units
Indoor fan motor
malfunction
Operation halt due to breaking
of wire inside the fan motor;
Operation halt due to breaking
of the fan motor lead wires;
Detection error due to faulty
indoor unit PCB;
Indoor unit- outdoor unit signal
transmission error du
e to wiring
error;
Faulty PCB;
Faulty EEPROM data;
Faulty EEPROM;
Faulty PCB;
Faulty connector connection;
Faulty thermistor;
Faulty PCB;
Room temperature
sensor failure
10
Содержание
- Keep this operation manual for future reference 1
- Lease read this operation manual before using the air conditioner 1
- Split type room air conditioner operation manual and indoor installation manual 1
- A leakage breaker must be installed make sure ground connection is correct and reliable 3
- Cautions 3
- Connecting cables break off it must be assured that the grouding wire is the last one to be broken off the breaker of the air conditioner should be all pole switch and the distance between its two contacts should not be no less than 3mm such means for disconnection must be incorporated in the wiring 3
- If the supply cord is damaged it must be replaced by the manufacturer its service agent or similarly qualified persons in order to avoid a hazard 3
- Make sure installation is done according to local wiring regulation by professional persons 3
- The type of connecting wire is h07rn f all the cables shall have got the european authentication certificate during installation when the 3
- The wiring method should be in line with the local wiring standard user maintenance shall not be made by children without supervision 3
- This appliance can be used by children aged 8 years and above and persons with reduced physical sensory or mental capabilities or lack of experience and knowledge if they have been given superivision or instruction concering use of the appliance in a safe way and understand the hazards involved children shall not play with the appliance cleaning and 3
- Warning 3
- Caution 4
- Cautions 4
- Check proper installation of the drainage securely 4
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 4
- Warning 4
- Accordance 5
- Before asking for service check the following first 5
- Conformity for the models 5
- Gwp global warming potential 5
- Important information rega rding the refrigerant used 5
- Trouble shooting 5
- Air purifying filter inlet 6
- Ambient temp display 6
- Anion generator 6
- Display board 6
- Emergency switch 6
- Extra function button 6
- Function 6
- Horizontal flap 6
- Indoor unit 6
- Inlet grille 6
- Inside 6
- Operation mode indicator 6
- Outdoor unit 6
- Outlet 6
- Parts and functions 6
- Power indicator 6
- Remote controller 6
- Remote signal receiver 6
- Timer mode indicator 6
- Vertical blade 6
- Air flow direction adjustment 7
- Base operation 7
- Cautions 7
- Emergency operation and test operation 7
- It is advisable not to keep horizontal flap at downward position for a long time in coolor dry otherwise condensate water might occur 7
- Operation 7
- When adjusting the flap by hand turn off the unit when humidity is high condensate water might occur 7
- Comfortable sleep 8
- Controller 8
- For a minute and then start adjusting by remote 8
- Healthy airflow operation 8
- In cool dry mode 8
- Modes are set up at the same time 8
- Operation 8
- Operation mode 8
- Setting the comfort work conditions 8
- According to the time setting sequence of timer on or 9
- After replacing batteries or a power failure happens time 9
- After unit starts select your desired operation mode 9
- Operation 9
- Press button 0 will appear after 10 seconds the time display will be blank 9
- Press button to change timer mode 9
- Press button to set time 9
- Setting should be reset 9
- Then select your desired timer mode timer on or 9
- Timer off either start stop or stop start can be achieved 9
- Timer off or will flash 9
- Timer on off on off operation 9
- Accessory parts 10
- Drawing for the installation of indoor units 10
- Indoor unit installation 10
- More than 10cm 10
- More than 15cm 10
- Necessary tools for installation power source 10
- Selection of installation place 10
- Selection of pipe 10
- Connecting the indoor outdoor electric cable 11
- Fixing the indoor unit body 11
- Indoor unit installation 11
- Left left rear piping 11
- Other direction piping 11
- Rear piping 11
- Removal of indoor unit body 11
- Removing the wiring cover 11
- Check for installation and test run 12
- Check items for test run 12
- Cutting and flaring work of piping 12
- On drainage 12
- Please kindly explain to our customers how to operate through the instruction manual 12
- Power source installation 12
- When connecting the cable after installing the indoor unit 12
- When connecting the cable before installing the indoor unit 12
- And the white side face the unit 13
- Attach air purifying filter 13
- Attach the filter 13
- Attach the standard air filter 13
- Clean the filter 13
- Close doors and windows during operation 13
- Close the grille surely 13
- Close the inlet grille 13
- Detach old air purifying filter 13
- Do not block the air inlet or outlet 13
- For smart use of the air conditioner 13
- If the unit is not to be used for a long time turn off the power supply main switch 13
- Maintenance 13
- Necessary installation 13
- Note air purifying filter is optional part 13
- Open the inlet grille by pulling it upward 13
- Please keep the bacteria killing medium air purifying filter in avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced 13
- Prop up the inlet grille by using a small device named grille support 13
- Purifying filter face outside 13
- Remove the filter 13
- Replacement of air purifying filter 13
- Setting of proper room temperature 13
- Slide the knob slightly upward to release the filter then withdraw it 13
- The bacteria killing medium air purifying filter will be used for a long time no need for replacement but in the period of using them you should remove the dust frequently by 13
- The cool and dry conditions 13
- The photocatalyst air purifying filter will be solarized in fixed time in normal family it will be solarized every 6 months 13
- Use the louvers effectively 13
- Use the timer effectively 13
- Using vacuum cleaner or flaping them lightly otherwise its performance will be affected 13
- Which located in the right side of the indoor unit 13
Похожие устройства
- Haier AS12BS4HRA Инструкция по монтажу
- Haier AS12BS4HRA Инструкция по эксплуатации
- Haier AS12BS4HRA Руководство по эксплуатации
- Haier AS15BS4HRA Инструкция по монтажу
- Haier AS15BS4HRA Инструкция по эксплуатации
- Haier AS15BS4HRA Руководство по эксплуатации
- Haier AS18BS4HRA Инструкция по монтажу
- Haier AS18BS4HRA Инструкция по эксплуатации
- Haier AS18BS4HRA Руководство по эксплуатации
- Haier AS24BS4HRA Инструкция по монтажу
- Haier AS24BS4HRA Инструкция по эксплуатации
- Haier AS24BS4HRA Руководство по эксплуатации
- Haier 3U19FS2ERA Инструкция по монтажу
- Haier 3U19FS2ERA Брошюра
- Haier 3U24GS2ERA Инструкция по монтажу
- Haier 3U24GS2ERA Брошюра
- Haier 4U30HS2ERA Брошюра
- Haier 4U30HS2ERA Инструкция по монтажу
- Theben SUL 181 d (1810011) Технический паспорт
- Theben SUL 181 d (1810011) Инструкция по эксплуатации