Haier 2U18FS1ERA [31/116] The frequency limitation of modification rate

Haier AS07GS2ERA [31/116] The frequency limitation of modification rate
2U14CS1ERA-SM
Functions and control
28
Domestic Air Conditioner
0ć Stop
When Tpg_indoorLJ ice_temp_1ć, the frequency of the compressor decreases at the speed of
1HZ/1second.
When Tpg_indoorLJ ice_temp_2ć, the frequency of the compressor decreases at the speed of
1HZ/10seconds.
When Tpg_indoor begins to rise again, and ice_temp_2LJ=Tpg_indoorLJ= ice_temp_3ć, the
frequency of thecompressor doesn’t change.
When ice_temp_3LJTpg_indoorLJice_temp_3+3ć, the frequency of the compressor increases at
the speed of 1HZ/10seconds.
For example, Tpg_indoor<= 0ćˈlast for 2 minutes, and then the outdoor unit will stop, and report
underload malfunction, but don’t send malfunction report to the indoor.
The compressor stops for more than 3 minutes, Tpg_indoor> ice_temp_3+2ć, the compressor
recovers.
5.2.5.6 The frequency limitation of modification rate
In the field which is controlled by high frequency, if the modification rate is not high enough,
the control-driven chip will enter into weak magnetic control, this will help to relieve the
problem of modification rate. If during the course of weak magnetic control, the modification rate
is still not high enough, enter into the control of decreasing frequency until the alarm of
modification rate is relieved.
5.2.5.7 The socket protect
If the socket temperature is higher than 120 ć ,the outdoor unit will stop,and report
malfunction(the LED light flashing 36 times).The compressor stops for more than 3 minutes,the
compressor recovers.
5.2.5.8 Temperature protection of the outdoor refrigerating coil
When the defrosting temperature and the sensor’s temperature are higher than 65ć, the
frequency of the compressor decreases 1hz/10seconds. Keep the frequency until it decreases to
the lowest frequency. When the temperatures are lower than 65ć and higher than 60ć, keep
the frequency of the compressor. When the temperatures are lower than 60ć, relieve the
defrosting temperature protection.
5.2.5.9
˖
Malfunction display and malfunction handling
a)ǃFor the complete appliance’s malfunctions˖Annex 2
If there’s malfunction with the outdoor unit, the light of the outdoor unit will flash and its frequency
is 1HZ, the number of times is according to the table, when a round of flashing is finished, the
light shoud be off for 5 seconds.
b)ǃFor the units’ malfunctins˖Annex 1
If there’s malfunction with the units, this will not affect the run of the complete appliance, but this
can be displayed by the malfunction light, the light flashing frequency is 0.5HZ, the number of
times is according to the malfunction table of the indoor units. When a round of flashing is
finished, the light shoud be off for 10 seconds. Then report according to the order : unit Aėunit B
ėunit Cėunit D, that is, if there’s malfunction with several units, then just report the indoor unit
with the highest priority level. Among the unit malfunctions, the priority level of the
communication malfunction is the highest, for others, that appears first will have the priority.
Remarks: in 3 minutes when the compressor stops, the units’ malfunctions are not displayed;