Cautions
2
11 .The power plug and connecting cable
must have acquired the local attestation.
2. If the power supply cord is damaged, it
must be replaced by the manufacturer
or its service agent or a similar qualified
person.
3. If the fuse of indoor unit on PC board is
broken,please change it with the type of
T. 3.15A/ 250V. If the fuse of outdoor unit
is broken, change it with the type of
T.25A/250V.
4. The wiring method should be in line with
the local wiring standard.
5. After installation, the power plug should
be easily reached.
6. The waste battery should be disposed
properly.
7. The appliance is not intended for use
by young children or infirm persons
without supervision.
8. Young children should be supervised
to ensure that they do not play with
the appliance.
10.Please employ the proper power plug,
which fit into the power supply cord.
Do not obstruct or cover the ventilation
grille of the air conditoner.Do not put fingers
or any other things into the inlet/outlet and
swing louver.
Do not allow children to play with the air
conditioner.In no case should children be
allowed to sit on the outdoor unit.
The refrigerating circuit is leak-proof.
1.Applicable ambient temperature range:
Specifications
The machine is adaptive in following
situation
Cooling
Indoor
Maximum:D.B/W.B
Maximum:D.B/W.B
Maximum:D.B
Maximum:D.B
Maximum:D.B
Minimum:D.B/W.B
Maximum:D.B/W.B
Minimum:D.B/W.B
Outdoor
Indoor
Outdoor
Heating
32
o
C/23
o
C
24
o
C/18
o
C
43
o
C/26
o
C
18
o
C
27
o
C
15
o
C
18
o
C/14
o
C
-15
o
C
12.In order to protect the units,please turn
off the A/C first, and at least 30 seconds
later, cutting off the power.
9. A breaker should be incorporated into
fixed wiring. The breaker should be
all-pole switch and the distance between
its two contacts should be not less than
3mm.
Содержание
- Floor unit operation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Safety instructions and warnings 2
- Cautions 3
- Specifications 3
- The machine is adaptive in following situation 3
- Caution 4
- Cautions 4
- Installation 4
- Safety instruction 4
- Use fuse with specified capacity replacement with steel or copper wires are absolutely prohibited 4
- Warning 4
- Caution 5
- Cautions 5
- Warning 5
- Control panel 6
- Filter inside 6
- Indoor unit 6
- Outdoor unit 6
- Outlet 6
- Parts and functions 6
- Air flow selection 7
- Caution 7
- Parts and functions 7
- When setting the air flow selection switch to 7
- When setting the air outlet selection switch to 7
- Parts and functions 8
- Remote controller 8
- Parts and functions 9
- About auto mode 10
- Auto operation 10
- Fan speed selection 10
- Operation 10
- Remote controller 10
- Select operation mode 10
- Select temp setting 10
- Unit start 10
- Unit stop 10
- Cool operation 11
- Fan speed selection 11
- Operation 11
- Remote controller 11
- Select operation mode 11
- Select temp setting 11
- Unit start 11
- Unit stop 11
- Dry operation 12
- Fan speed selection 12
- Operation 12
- Remote controller 12
- Select operation mode 12
- Select temp setting 12
- Unit start 12
- Unit stop 12
- About fan operation 13
- Fan operation 13
- Fan speed selection 13
- Operation 13
- Remote controller 13
- Select operation mode 13
- Unit start 13
- Unit stop 13
- Fan speed selection 14
- Heat operation 14
- Operation 14
- Remote controller 14
- Select operation mode 14
- Select temp setting 14
- Unit start 14
- Unit stop 14
- Adjusting the air flow direction 15
- Adjusting the flap 15
- Adjusting the louver 15
- Attention 15
- Caution 15
- Operation 15
- Operation 16
- Remote controller 16
- Sleep operation 16
- Operation 17
- Remote controller 17
- Timer on off operation 17
- Operation 18
- Remote controller 18
- Timer on off operation 18
- Operation 19
- Power operation 19
- Power soft operation 19
- Soft operation 19
- C do not it in the normal operation 20
- Carry out this operation only when the remote controller is defective or lost 20
- Continue to press the test operation switch for more than 5 seconds after you hear the bi sound twice release your finger from the switch the test operation starts and the air conditioner starts with the air flow speed setting hi 20
- Emergency operation 20
- Emergency operation and test operation 20
- Follow the requirements below 20
- Operation 20
- Push the test run switch or operate with remote controller to cancel the test run if you use the remote controller to cancel the test run the conditioner will then run as per the working mode displayed on the remote controller 20
- Test operation 20
- Unit start 20
- Unit stop to cancel emergency operation press the emergency switch and hear a sound the unit stops 20
- Unit stop to cancel test operation 20
- Use this switch in the test operation when the room temperature is less 1 20
- When the emergency operation switch is pressed a sound you can hear which means the start of this operation 20
- Operation hints 21
- Power failure resume please set and apply as necessary 21
- Remote monitoring 21
- Setting method 21
- To cancel 21
- Cleaning of the unit 22
- Maintenance 22
- Check there are no obstacles in the air inlet and outlet to avoid impairing of working efficiency 23
- Maintenance 23
- Maintenance at the end of application season 23
- Maintenance before beginning of application season 23
- Please do attach the air filter to ensure the electrostatic filters not soiled otherwise dirt will come into and damage the unit or bring failures 23
- Before asking for service check the following first 24
- Trouble shooting 24
- Installation manual of room air conditioner 25
- Installation of indoor unit 25
- Installation of outdoor unit 25
- Fixing of the unit 26
- Gas leakage detector or soap water 11 measuring tape 26
- Installation manual of room air conditioner 26
- Pipe cutter 7 flaring tool 8 knife 9 nipper 26
- Reamer 26
- Refrigerant oil 26
- Screw driver 2 hacksaw 3 0mm dia hole core drill 4 spanner dia 7 27mm 26
- Spanner 14 17 27mm 26
- Standard accessories 26
- Tool necessary 26
- Installation manual of room air conditioner 27
- Piping connection 27
- Piping connection of the indoor unit 27
- For r410a 28
- Installation manual of room air conditioner 28
- Purging method 28
- Installation manual of room air conditioner 29
- Piping connection of the outdoor unit connecting the connecting pipe and inlet and outlet liquid pipe according to the piping method 29
- Purging method for r407c 29
- Electric wiring note 30
- Installation manual of room air conditioner 30
- Wiring of indoor unit 30
- Wiring of outdoor unit 30
- Flare tooling die 31
- Installation manual of room air conditioner 31
- Others 31
Похожие устройства
- Haier HFU-09H03/R2(DB) Инструкция по эксплуатации
- Haier HFU-12H03/R2(DB) Инструкция по эксплуатации
- Haier HFU-18H03/R2(DB) Инструкция по эксплуатации
- Haier AU422BIBAA Инструкция по эксплуатации
- Haier AS09SB1HRA Инструкция по эксплуатации
- Haier AS12SB1HRA Инструкция по эксплуатации
- Haier 1U09QE6ERA Инструкция по эксплуатации
- Haier 1U12QE6ERA Инструкция по эксплуатации
- Haier HSU-07СS03 Инструкция по эксплуатации
- Haier HSU-07HS03 Инструкция по эксплуатации
- Haier HSU-09CS03 Инструкция по эксплуатации
- Haier HSU-09HS03 Инструкция по эксплуатации
- Haier AS072ADMAA Инструкция по эксплуатации
- Haier AS072ADAAA Инструкция по эксплуатации
- Haier AS092ADMAA Инструкция по эксплуатации
- Haier AS092ADAAA Инструкция по эксплуатации
- Haier H2SM-14HS03 Инструкция по эксплуатации
- Haier AS072BDAAA Инструкция по эксплуатации
- Haier AU142BNAAA Инструкция по эксплуатации
- Hyundai H-LED24FT2000 Инструкция по эксплуатации