Haier HSU-12LEA13-F [2/8] Cool display
![Haier HSU-18LEA13-H [2/8] Cool display](/views2/1814853/page2/bg2.png)
Display board
Signal receiver hole
COOL display
HEAT display
HEALTH display
Dry display
4
2
3
1
6
7
5
8
Parts and Functions
4
2
3
1
6
5
(If the unit which you purchased
has healthy function,follow it.
TIMER OFF display
TIMER ON display
SLEEP display
If not,please ignore.)
7
ON/OFF
TEMP
MODE SET
FAN
TIMER
SWING
CLOCK
SLEEP
LOCK RESET
5
6
7
8
9
10
19
20
21
22
23
4
1
2
3
11
12
13
14
15
16
A
U
T
O
ON OFF
AM
PM
o
C
17
18
24
HEALTH
1. Operation mode display
2. SWING display
3. FAN SPEED display
LO MED HIAUTO
5. SLEEP display
6. LOCK display
7. SIGNAL SENDING display
8. TIMER OFF display
9. TIMER ON display
10. CLOCK display
1
1. TEMP display
12. POWER ON/OFF
Used for unit start and stop.
13. MODE
Used to select
AUTO run, COOL,
HEAT DRY and FAN operation
15. HOUR
Used to set clock and timer setting.
16. SWING
Used to set auto fan direction.
17. SLEEP
Used to select sleep mode.
18. LOCK
Used to lock buttons and LCD
displa
y.
19. TEMP.
Used to select your desired temp.
20. SET
Used to confirm timer and clock
21. TIMER
Used to select TIMER ON,
TIMER OFF,
TIMER ON-OFF
22. CLOCK
Used to set correct time
23. RESET
normal condition.
Used to reset the controller back to
4. HEALTH display
24. HEALTH
Used to operate the healthy function
25.
14. FAN
Used to select fan speed LO, MED,
HI, AUTO
Ambient temp.display
When receiving the remote control signal,
display the set temperature and in the rest
this room temperature is only for reference.
time the room temperature is displayed and
25
POWER/SOFT
POWER/SOFT button
26
POWER/SOFT display
26.
MODE SET
FAN
TIMER
SWING
CLOCK
6
5
2
1
4
3
Inlet grille
Inlet
Air Purifying Filter (inside)
Outlet
Horizontal flap
6
4
2
1
5
3
5
2
1
5
3
6
8
Parts and Functions
Actual inlet grille may vary from the one shown in the
manual according to the product purchased
(adjust up and down air flow
Don't adjust it manually)
(adjust left and right air flow)
Vertical blade
Remote controller
If the unit which you purchased has healthy function,follow it.If not,please ignore.
NOTE:
Cooling only unit do not have displays and functions related with heating
4
Outdoor Unit
14
Indoor Unit
OUTLET
INLET
CONNECTING PIPING AND ELECTRICAL WIRING
DRAIN HOSE
1
2
3
4
Remove the battery cover;
Load the batteries as
illustrated. 2 R-03 batteries,
resetting key(cylinder);
Be sure that the loading
is in line with th
e" + "/"-";
Load the battery,then put on the cover again.
The distance between the signal transmission head and the
receiver hole should be within 7m without any obstacle as well.
When electronic-started type fluorescent lamp or change-over
so the distance to the indoor unit should be shorter.
wireless telephone is installed in the type fluorescent lamp or
room, the receiver is apt to be disturbed in receivingthe signals,
Note:
Full display or unclear display during operation indicates the
ries have been used up.
Please change batteries.
If the remote controller can't run normally during operation,
reload several minutes later.
batte
remove the batteries and
Remove the batteries in case unit won't be in usage for a long period.
If there are any display
after taking-out, just need to press reset key
Hint:
Loading of the battery
please
Clock set
Press CLOCK button, "AM" or "PM" flashes.
Press or to set correct time. Each press
change quickly.
After time setting is confirmed,press SET,
"AM "and "PM" stop flashing,while clock starts working.
or decrease 1min. If the
button is kept pressed,time will
will increase
Operation mode
AUTO
FAN
COOLDRY
Remote controller
Display board
HEAT
settings.
7
(inside)
Anion generator
7
1
2
3
This function is unavailable on
some models.
This function is unavailable on
some models.
(This function is unavailable on
some models.)
(This function is unavailable on
some models.)
1
Содержание
- Contents 1
- Hsu 12ca2 hsu 09ca2 1
- Hsu 12cb2 hsu 18lb2 hsu 18la2 1
- Hsu 24la2 hsu 12heb03 1
- Operation manual 1
- Split type room air conditioner 1
- 2 3 1 6 5 2
- Actual inlet grille may vary from the one shown in the manual according to the product purchased 2
- After time setting is confirmed press set am and pm stop flashing while clock starts working 2
- Air purifying filter inside 2
- Anion generator 2
- Be sure that the loading is in line with the load the battery then put on the cover again 2
- Cool display 2
- Dry display 2
- Heat heat display 2
- Indoor unit 2
- Load the batteries as illustrated 2 r 03 batteries resetting key cylinder 2
- Or decrease 1min if the 2
- Outdoor unit 2
- Parts and functions 2
- Press clock button am or pm flashes press or to set correct time each press 2
- Remote controller 2
- Signal receiver hole 2
- Timer off display 2
- Will increase 2
- According to room 3
- Air flow direction adjustm 3
- Auto operation 3
- Automatically adjusts 3
- C unit will run intermittently at low speed regardless of fan setting 3
- Cool operation 3
- Cooling only unit do not have displays and functions related with heating 3
- Display board remote controller note 3
- Dry operation 3
- Due to cold draft prevention function 3
- Fan operation 3
- Fan timer 3
- Heat operation 3
- In dry mode when room temperature becomes lower than temp 3
- In dry mode when room temperature becomes lower than temp setting 3
- In fan mode auto is not available in fan mode and temp setting is disabled 3
- In fan operation mode 3
- In fan operation mode the unit will not operate in cool or heat mode but only in fan mode auto is not available in fan mode and temp setting is disabled in fan mode sleep operation is not available 3
- In heat mode warm air will blow out after a short periodof the time 3
- Mode set 3
- Next time just press on off button and unit will run in previous status remote controller can memorize each operation status when starting it 3
- Of fan setting 3
- Operation 3
- Operation mode 3
- Press on off button unit starts or stops 3
- Select temp setting 3
- Setting 2 c unit will run intermittently at low speed regardless 3
- Sleep health 3
- Swing clock 3
- The fan speed according to room temperature 3
- The unit will not operate in cool mode but only 3
- Under the mode of auto operation air conditioner will automatically select cool or heat operation according to room temperature air conditioner automatically adjusts the fan speed temperature 3
- Unit start stop 3
- When fan is set to auto the 3
- When fan is set to auto the air conditioner 3
- When fan is set to auto the air conditioner automatically adjusts 3
- 2 timer off 4
- After 30 minutes test operation ends automatically only for 22k 24k unit 4
- Also to kill bacteria and speed up the dust sediment 4
- Anion effectively balance the quantity of position and anion in 4
- Automatically takes low speed of auto fan mode 4
- Continue to press the test operation switch for more than 5 seconds after you hear the pi sound twice 4
- Health operation 4
- Healthy negative ions 4
- In cool mode fan speed automatically takes high speed of auto fan mode in heat mode fan speed automatically takes medial speed of auto fan mode 4
- In soft operation mode fan speed 4
- In the room and finally clean the air in the room 4
- In this operation the system automatically selects the operation modes cooling or fan or heat according to the room temperature 4
- Is needed for rest or reading 4
- It is not possible to operate in dry mode 4
- Just press timer button several times untiltimer mode disappears 4
- Operation 4
- Operation starts with the air flow speed hi 4
- Or after you fall asleep at night 4
- Power operation 4
- Power soft operation 4
- Press power soft button again power soft disappears 4
- Set clock correctly before starting timer operation 4
- Soft operation 4
- Test operation 4
- Test operation switch is the same as emergency switch 4
- The anion generator in the airconditioner can generate a lot of the air and 4
- This function is unavailable on some models 4
- Timer on 4
- Timer on of 4
- Timer operation 4
- To cancel power operation 4
- To cancel soft operation 4
- To cancel timer mode 4
- Use this operation only when the remote controller is defective or lost 4
- When the emergency operation switch is pressed the pi sound is heard once which means the start of this operation 4
- When you need rapid heating or cooling 4
- You can let unit start or stop automatically a following times before you wake up in the morning or get back from outside 4
- You can use this function 4
- You can use this function when silence 4
- Your finger from the switch the cooling 4
- Comfortable sleep 5
- Operation 5
- Operation mode 5
- And the white side face the unit 6
- Attach air purifying filter 6
- Attach the filter 6
- Attach the standard air filter 6
- Clean the filter 6
- Close doors and windows during operation 6
- Close the grille surely 6
- Close the inlet grille 6
- Detach old air purifying filter 6
- Do not block the air inlet or outlet 6
- For smart use of the air conditioner 6
- If the unit is not to be used for a long time turn off the power supply main switch 6
- Maintenance 6
- Necessary installation 6
- Note air purifying filter is optional part 6
- Open the inlet grille by pulling it upward 6
- Please keep the bacteria killing medium air purifying filter in avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced 6
- Prop up the inlet grille by using a small device named grille support 6
- Purifying filter face outside 6
- Put air purifying filter appliances into the right and left filter frames 6
- Remove the filter 6
- Replacement of air purifying filter 6
- Setting of proper room temperature 6
- Slide the knob slightly upward to release the filter then withdraw it 6
- The bacteria killing medium air purifying filter will be used for a long time no need for replacement but in the period of using them you should remove the dust frequently by 6
- The cool and dry conditions 6
- The photocatalyst air purifying filter will be solarized in fixed time in normal family it will be solarized every 6 months 6
- Use the louvers effectively 6
- Use the timer effectively 6
- Using vacuum cleaner or flaping them lightly otherwise its performance will be affected 6
- Which located in the right side of the indoor unit 6
- Caution 7
- Cautions 7
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 7
- Warning 7
- Applicable ambient temperature range 8
- Application temp range of air conditioner 7 8
- Before asking for service check the following first 8
- Cautions 8
- Cooling 8
- For t1 8
- For t3 8
- Heating 8
- Indoor 8
- Maximum d b 8
- Maximum d b w b 32 8
- Minimum d b maximum d b minimum d b maximum d b w b minimum d b w b 8
- Minimum d b w b 8
- Outdoor 8
- Person 8
- Trouble shooting 8
Похожие устройства
- Haier HSU-12LEA13-M Инструкция по монтажу
- Haier HSU-12LEA13-M Руководство по эксплуатации
- Haier HSU-12LEA13-M Инструкция по эксплуатации
- Haier HSU-18LEA13-M Инструкция по монтажу
- Haier HSU-18LEA13-M Руководство по эксплуатации
- Haier HSU-18LEA13-M Инструкция по эксплуатации
- Haier HSU-12LEB13-H Инструкция по монтажу
- Haier HSU-12LEB13-H Инструкция по эксплуатации
- Haier HSU-14LEB13-H Инструкция по монтажу
- Haier HSU-14LEB13-H Инструкция по эксплуатации
- Haier HSU-09CRA03-T Инструкция по монтажу
- Haier HSU-09CRA03-T Инструкция по эксплуатации
- Hyundai H-TAE100 Инструкция по эксплуатации
- Hyundai H-TAE120 Инструкция по эксплуатации
- Hyundai H-TAE140 Инструкция по эксплуатации
- Hyundai H-TAE200 Инструкция по эксплуатации
- Hyundai H-TAE220 Инструкция по эксплуатации
- Hyundai H-TAE240 Инструкция по эксплуатации
- Hyundai H-TAE260 Инструкция по эксплуатации
- Hyundai H-TAI400 Инструкция по эксплуатации