Haier HSU-14LEB13-H [8/8] Applicable ambient temperature range
![Haier HSU-18LEA13-H [8/8] Applicable ambient temperature range](/views2/1814853/page8/bg8.png)
Trouble shooting
7
Before asking for service, check the following first.
Normal
Performance
inspection
Noise is heard
Phenomenon
Cause or check points
The system does not restart
immediately.
Smells are generated.
Mist or steam are blown out.
Multiple
check
Poor cooling
Application temp. range of air conditioner -7
o
C~43
o
C.
When unit is stopped, it won't restart
elapsed to protect the system.
When the electric plug is pulled out
and reinserted, the protection circuit
During unit operation or at stop,
a swishing or gurgling noise may
(This noise is generated by
refrigerant flowing in the system.)
During unit operation, a cracking
noise may be heard.This noise is
temperature changes.
Should there be a big noise from
filter may be too dirty.
This is because the system
circulates smells from the interior
During COOL or DRY operation,
This is due to the sudden cooling
Is power plug inserted?
Is there a power failure?
Is fuse blownout?
Is the air filter dirty?
Are there any obstacles before
Is temperature set correctly?
Are there some doors or
Is there any direct sunlight
through the window during the
Are there too much heat sources
or too many people in the room
In dry mode,
fan
speed can’t be changed.
In DRY mode, when room
than temp.setting+2
o
C,unit will
regardless of FAN setting.
Maximum: D.B
10.The appliance must be installed on a strong enough support.
9.Young children should be supervised ensure that they do not
play with the appliance.
8.The appliance is not intended to use by young children or infirm
persons without supervision.
7.The used batteries should be disposed of properly.
6.
After installation, the power plug should be easily reached..
5.The wiring method should be in line with the local wiring standard.
4.The distance between the indoor unit and the floor should be
more than 2m.
3. If the fuse on PC board is broken please change it with a fuse
type T. 3.15A/250V.
11.The wiring diagram is attached inside the machine.
2. If the supply cord is damaged, it must be replaced by the
manufacturer or its service agent or a similar qualified
person.
The type of connecting wire is H05RN-F or H07RN-F
Cautions
The machine is adaptive in following situation
1.Applicable ambient temperature range:
Cooling
Heating
Indoor
Outdoor
Outdoor
Indoor
Maximum: D.B / W.B 32
o
C/23
o
C
18
o
C/14
o
C
43
o
C/26
o
C
18
o
C
27
o
C
15
o
C
24
o
C/18
o
C
-7
o
C/-8
o
C
Minimum: D.B / W.B
Minimum: D.B
Maximum: D.B
Minimum: D.B
Maximum: D.B / W.B
Minimum: D.B / W.B
For: T3
Cooling
Heating
Indoor
Outdoor
Indoor
Outdoor
Maximum: D.B / W.B
Minimum: D.B / W.B
Maximum: D.B / W.B
Minimum: D.B
Maximum: D.B
Minimum: D.B
Maximum: D.B / W.B
Minimum: D.B / W.B
29
o
C/19
o
C
18
o
C/14
o
C
54
o
C/24
o
C
18
o
C
27
o
C
15
o
C
24
o
C/18
o
C
-7
o
C/-8
o
C
For: T1
during cooling operation?
cooling operation?(Use curtain)
windows left open?
inlet and outlet?
Normally it should be cleaned
every 15 days.
run intermittently at LOW speed
temperature becomeslower
indoor unit may blow out mist.
of indoor air.
air such as the smell of furniture,
paint, cigarettes.
air flow in unit operation, air
generated by the casing expanding
or shrinking because of
be heard.At first 2-3 minutes after
unit start, this noise is more noticeable.
will work for 3 minutes to protect the
air conditioner.
immediately until 3 minutes have
If the fuse of outdoor unit on PC board is broken, please change
it with the type of T. 25A/250V.
Application temp. range of air conditioner -7
o
C~54
o
C.
T1:
T3:
Содержание
- Contents 1
- Hsu 12ca2 hsu 09ca2 1
- Hsu 12cb2 hsu 18lb2 hsu 18la2 1
- Hsu 24la2 hsu 12heb03 1
- Operation manual 1
- Split type room air conditioner 1
- 2 3 1 6 5 2
- Actual inlet grille may vary from the one shown in the manual according to the product purchased 2
- After time setting is confirmed press set am and pm stop flashing while clock starts working 2
- Air purifying filter inside 2
- Anion generator 2
- Be sure that the loading is in line with the load the battery then put on the cover again 2
- Cool display 2
- Dry display 2
- Heat heat display 2
- Indoor unit 2
- Load the batteries as illustrated 2 r 03 batteries resetting key cylinder 2
- Or decrease 1min if the 2
- Outdoor unit 2
- Parts and functions 2
- Press clock button am or pm flashes press or to set correct time each press 2
- Remote controller 2
- Signal receiver hole 2
- Timer off display 2
- Will increase 2
- According to room 3
- Air flow direction adjustm 3
- Auto operation 3
- Automatically adjusts 3
- C unit will run intermittently at low speed regardless of fan setting 3
- Cool operation 3
- Cooling only unit do not have displays and functions related with heating 3
- Display board remote controller note 3
- Dry operation 3
- Due to cold draft prevention function 3
- Fan operation 3
- Fan timer 3
- Heat operation 3
- In dry mode when room temperature becomes lower than temp 3
- In dry mode when room temperature becomes lower than temp setting 3
- In fan mode auto is not available in fan mode and temp setting is disabled 3
- In fan operation mode 3
- In fan operation mode the unit will not operate in cool or heat mode but only in fan mode auto is not available in fan mode and temp setting is disabled in fan mode sleep operation is not available 3
- In heat mode warm air will blow out after a short periodof the time 3
- Mode set 3
- Next time just press on off button and unit will run in previous status remote controller can memorize each operation status when starting it 3
- Of fan setting 3
- Operation 3
- Operation mode 3
- Press on off button unit starts or stops 3
- Select temp setting 3
- Setting 2 c unit will run intermittently at low speed regardless 3
- Sleep health 3
- Swing clock 3
- The fan speed according to room temperature 3
- The unit will not operate in cool mode but only 3
- Under the mode of auto operation air conditioner will automatically select cool or heat operation according to room temperature air conditioner automatically adjusts the fan speed temperature 3
- Unit start stop 3
- When fan is set to auto the 3
- When fan is set to auto the air conditioner 3
- When fan is set to auto the air conditioner automatically adjusts 3
- 2 timer off 4
- After 30 minutes test operation ends automatically only for 22k 24k unit 4
- Also to kill bacteria and speed up the dust sediment 4
- Anion effectively balance the quantity of position and anion in 4
- Automatically takes low speed of auto fan mode 4
- Continue to press the test operation switch for more than 5 seconds after you hear the pi sound twice 4
- Health operation 4
- Healthy negative ions 4
- In cool mode fan speed automatically takes high speed of auto fan mode in heat mode fan speed automatically takes medial speed of auto fan mode 4
- In soft operation mode fan speed 4
- In the room and finally clean the air in the room 4
- In this operation the system automatically selects the operation modes cooling or fan or heat according to the room temperature 4
- Is needed for rest or reading 4
- It is not possible to operate in dry mode 4
- Just press timer button several times untiltimer mode disappears 4
- Operation 4
- Operation starts with the air flow speed hi 4
- Or after you fall asleep at night 4
- Power operation 4
- Power soft operation 4
- Press power soft button again power soft disappears 4
- Set clock correctly before starting timer operation 4
- Soft operation 4
- Test operation 4
- Test operation switch is the same as emergency switch 4
- The anion generator in the airconditioner can generate a lot of the air and 4
- This function is unavailable on some models 4
- Timer on 4
- Timer on of 4
- Timer operation 4
- To cancel power operation 4
- To cancel soft operation 4
- To cancel timer mode 4
- Use this operation only when the remote controller is defective or lost 4
- When the emergency operation switch is pressed the pi sound is heard once which means the start of this operation 4
- When you need rapid heating or cooling 4
- You can let unit start or stop automatically a following times before you wake up in the morning or get back from outside 4
- You can use this function 4
- You can use this function when silence 4
- Your finger from the switch the cooling 4
- Comfortable sleep 5
- Operation 5
- Operation mode 5
- And the white side face the unit 6
- Attach air purifying filter 6
- Attach the filter 6
- Attach the standard air filter 6
- Clean the filter 6
- Close doors and windows during operation 6
- Close the grille surely 6
- Close the inlet grille 6
- Detach old air purifying filter 6
- Do not block the air inlet or outlet 6
- For smart use of the air conditioner 6
- If the unit is not to be used for a long time turn off the power supply main switch 6
- Maintenance 6
- Necessary installation 6
- Note air purifying filter is optional part 6
- Open the inlet grille by pulling it upward 6
- Please keep the bacteria killing medium air purifying filter in avoid long time directly sunshine when you stop using it or its ability of sterilization will be reduced 6
- Prop up the inlet grille by using a small device named grille support 6
- Purifying filter face outside 6
- Put air purifying filter appliances into the right and left filter frames 6
- Remove the filter 6
- Replacement of air purifying filter 6
- Setting of proper room temperature 6
- Slide the knob slightly upward to release the filter then withdraw it 6
- The bacteria killing medium air purifying filter will be used for a long time no need for replacement but in the period of using them you should remove the dust frequently by 6
- The cool and dry conditions 6
- The photocatalyst air purifying filter will be solarized in fixed time in normal family it will be solarized every 6 months 6
- Use the louvers effectively 6
- Use the timer effectively 6
- Using vacuum cleaner or flaping them lightly otherwise its performance will be affected 6
- Which located in the right side of the indoor unit 6
- Caution 7
- Cautions 7
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 7
- Warning 7
- Applicable ambient temperature range 8
- Application temp range of air conditioner 7 8
- Before asking for service check the following first 8
- Cautions 8
- Cooling 8
- For t1 8
- For t3 8
- Heating 8
- Indoor 8
- Maximum d b 8
- Maximum d b w b 32 8
- Minimum d b maximum d b minimum d b maximum d b w b minimum d b w b 8
- Minimum d b w b 8
- Outdoor 8
- Person 8
- Trouble shooting 8
Похожие устройства
- Haier HSU-09CRA03-T Инструкция по монтажу
- Haier HSU-09CRA03-T Инструкция по эксплуатации
- Hyundai H-TAE100 Инструкция по эксплуатации
- Hyundai H-TAE120 Инструкция по эксплуатации
- Hyundai H-TAE140 Инструкция по эксплуатации
- Hyundai H-TAE200 Инструкция по эксплуатации
- Hyundai H-TAE220 Инструкция по эксплуатации
- Hyundai H-TAE240 Инструкция по эксплуатации
- Hyundai H-TAE260 Инструкция по эксплуатации
- Hyundai H-TAI400 Инструкция по эксплуатации
- Hyundai H-TAI260 Инструкция по эксплуатации
- Hyundai H-TAI280 Инструкция по эксплуатации
- Hyundai H-TAI380 Инструкция по эксплуатации
- Hyundai H-TAI100 Инструкция по эксплуатации
- Hyundai H-TAI200 Инструкция по эксплуатации
- Hyundai H-TAI220 Инструкция по эксплуатации
- Hyundai H-TAI240 Инструкция по эксплуатации
- Hyundai H-TAI300 Инструкция по эксплуатации
- Hyundai H-TAI320 Инструкция по эксплуатации
- Hyundai H-TAI340 Инструкция по эксплуатации