Haier HSU-09CK3W3N [3/8] Base operation
![Haier HSU-12CKAB3N [3/8] Base operation](/views2/1815023/page3/bg3.png)
Operation
Air Flow Direction Adjustment
Base Operation
Remote controller
Emergency operation and test operation
Emergency Operation:
Use this operation only when the remote controller is defective
or lost, and with function of emergency running, air conditoner
can run automatically for a while.
When the emergency operation switch is pressed, the " Pi "
sound is heard once, which means the start of this operation.
When power switch is turning on for the first time and
emergency operation starts, the unit will run automatically in
the following modes:
It is impossible to change the settings of temp. and fan speed,It
is also not possible to operate in timer or dry mode.
Pi
HEALTH
SLEEP
TIME
OFF
TIME
ON
1
TURBO
/QUIET
SWING
1
2
2
Press FAN button. For each press, fan speed
follows:
Remote controller:
Press
button
Every time the button is pressed, temp.setting
increase 1
o
C,if kept depressed, it will increase
rapidly
Every time the button is pressed, temp.setting
decrease 1
o
C,if kept depressed, it will
decrease rapidly
Select a desired temperature.
4.Fan speed selection
3.Select temp.setting
Air conditioner is running under displayed fan speed.
When FAN is set to AUTO, the air conditioner
automatically adjusts the fan speed according to room
temperature.
1. Unit start
Press ON/OFF on the remote controller, unit starts.
/
2. Select operation mode
COOL button:Cooling mode
FAN button: Faning mode
DRY button: Dehumidify mode
Display
circulated
changes as
LOW
MED HI
AUTO
Remote
Controller
Note
In DRY mode , when room temperature becomes lower
than temp.setting+2
o
C, unit will run intermittently at LOW
speed regardless of FAN setting.
Under the mode of auto operation, air conditioner will
automatically select Cool or Heat operation according to
room temperature. When FAN is set to AUTO the air
conditioner automatically adjusts the fan speed according
to room temperature.
In FAN operation mode , the unit will not operate in COOL or
HEAT mode but only in
FAN mode, AUTO is not available in
FAN mode. And temp. setting is disabled. In FAN mode,
sleep operation is not available.
Operation
Mode
DRY
COOL
AUTO
FAN
3
3
4
temperature.
according to room
temperature is below 16
o
C, do not use it in the
Test operation:
Use this switch in the test operation when the room
normal operation.
your finger from the switch: the cooling
Continue to press the test operation
switch for more than 5 seconds . After
you hear the "Pi" sound twice,
release
Test operation switch is the same as emergency switch.
operation starts with the air flow speed "Hi".
Under this operation mode,the fan motor of indoor
unit will run in high speed.
Pi Pi
Room
temperature
Designated
temperature
Timer
mode
Fan
speed
Operation
mode
Above 23
o
C 26
o
C AUTO COOL
No
When restart after remote turning off, the remote controller
When adjusting the flap by hand,turn off the unit.
When humidity is high,condensate water might occur
It is advisable not to keep horizontal flap at downward
position for a long time in COOLor DRY
otherwise, condensate water might occur.
adjusted to left or at air outlet if all vertical louvers are right.
mode ,
controller will automatically memorize the previous set swing position.
Note:
Vertical flap
Pos.1
(Auto
swing)
1.Status display of air flow
2.Left and right air flow adjustment
Pos.1
Pos.2
Pos.3
Pos.4
Pos.5
Pos.6
For each press of button, remote controller
displays as follows :
remote controller:
Cautions:
Initial state
Pos.2 No initial state disaplayed on remote controller, the
vertical flap will be fixed on the current position
3
Содержание
- Contents 1
- Parts and functions operation maintenance 1
- Please read this operation manual before using the air conditioner keep this operation manual for future reference 1
- Split type room air conditioner operation manual 1
- Trouble shooting cautions 6 1
- Actual inlet grille may vary from the one shown in the manual according to the product purchased 2
- Ambient temp display 2
- Aureole 2
- Cool blue auto white dry cyan fan yellow green nano aquo 2
- Display mode the aureole display different colour when setting different function 2
- Load the battery then put on the cover again 2
- Operation mode indicator 2
- Outdoor unit 2
- Parts and functions 2
- Power indicator 2
- Remote signal receiver 2
- Remove the battery cover load the batteries as illustrated 2 r 03 batteries resetting key cylinder be sure that the loading is in line with t 2
- Temp display 2
- Timer mode indicator 2
- Air flow direction adjustment 3
- Base operation 3
- Cautions 3
- Emergency operation and test operation 3
- It is advisable not to keep horizontal flap at downward position for a long time in coolor dry otherwise condensate water might occur 3
- Operation 3
- When adjusting the flap by hand turn off the unit when humidity is high condensate water might occur 3
- Health operation 4
- In auto mode 4
- In fan mode 4
- Nano aqua generator adopt two high voltage pole to ionize the water molecule into nanometer water ion and release these ions to the air to kill the bacterium and refresh the air as well as the nanometer water inon can be easily absorbed by skin keeping moisture anytime 4
- Operation 4
- Operation mode 4
- Sleep operation 4
- Turbo quiet operation 4
- After setting the healthy airflow function the position 5
- Controller 5
- Grill is fixed 5
- In cooling and dry using the air conditioner for a long 5
- In cooling it is better to select the mode 5
- Occur at the grille 5
- Operation 5
- Setting the comfort work conditions 5
- Stop for a minute and then start adjusting by remote 5
- Time under the high air humidity condensate water may 5
- Timer on off on off operation health airflow operation 5
- Air filter cleaning 6
- Attach air purifying filter 6
- Attach the standard air filter 6
- Attention 6
- Close doors and windows during operation 6
- Close the inlet grille 6
- Detach the standard air filter 6
- Do not block the air inlet or outlet 6
- Do not use the following for cleaning 6
- For smart use of the air conditioner 6
- If the unit is not to be used for a long time turn off the power supply main switch 6
- Maintenance 6
- Open the lnlet grille 6
- Remote controller indoor body 6
- Replacement of air purifying filter 6
- Setting of proper room temperature 6
- Use the louvers effectively 6
- Use the timer effectively 6
- Caution 7
- Cautions 7
- Check proper installation of the drainage securely 7
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 7
- Warning 7
- Address no haier road hi tech zone qingdao 266101 p r china 8
- Before asking for service check the following first 8
- Cautions 8
- Contacts tel 86 532 8893 6943 fax 86 532 8893 1010 8
- Trouble shooting 8
- Website www haier com 8
Похожие устройства
- LEO LVR32-7-2 Сертификат
- LEO LVR32-7-2 Инструкция по эксплуатации
- LEO LVR32-7-2 Каталог
- LEO LVS32-7-2 Инструкция по эксплуатации
- LEO LVS32-7-2 Сертификат
- LEO LVS32-7-2 Каталог
- LEO LVR32-7 Инструкция по эксплуатации
- LEO LVR32-7 Сертификат
- LEO LVR32-7 Каталог
- LEO LVS32-7 Инструкция по эксплуатации
- LEO LVS32-7 Сертификат
- LEO LVS32-7 Каталог
- LEO LVR32-8-2 Инструкция по эксплуатации
- LEO LVR32-8-2 Сертификат
- LEO LVR32-8-2 Каталог
- LEO LVS32-8-2 Инструкция по эксплуатации
- LEO LVS32-8-2 Каталог
- LEO LVS32-8-2 Сертификат
- LEO LVR32-8 Инструкция по эксплуатации
- LEO LVR32-8 Сертификат