Haier AF092XCEAA [9/17] Maintenance
![Haier AF092XCEAA [9/17] Maintenance](/views2/1816410/page9/bg9.png)
Maintenance
Maintenance at the end of application season
On a fine day, unit shall be started and operate in
FAN mode for about half a day until the inside of
the unit becomes thoroughly dry.
Turn off the unit operation switch and power on/off.
Otherwise,there will be some electricity consumption
even the unit is in stop status.
Clean the filter and indoor,cover the units well.
Maintenance before beginning of application season
Check there are no obstacles in the air
inlet and
outlet to avoid impairing of working
efficiency.
Please do attach the air filter to ensure the
electrostatic filters not soiled.Otherwise,dirt
will come into and damage the unit or bring
failures.
7
Cleaning of the unit
Take off the air inlet grill
First switch off the power supply,take off the
screw cap,loosen the screw with cross screwdriver .
Clean the filter
Use water or vacuum cleaner to remove
dust. If it is too dirt, clean with detergent or
neutral soap water.
Rinsing with fresh water, dry the filter and
re-assemble.
Caution:
Do not wash filter in hot water above 40∞C,
which will damage the filter.
Do carefully wipe the filter.
Clean the indoor(outdoor) unit
Clean with warm cloth or neutral detergent,
then wipe away moisture with dry cloth. Do
not use too hot water(above 40∞C),which will
cause discoloration or deformation. Do not
use pesticide or other chemical detergents.
Turn off the power switch
Do not touch with wet hand
Do not clean with hot
water or solvent
Содержание
- Console type 1
- Oom air conditioner indoor units 1
- Operation and installation manual 1
- Table of contents 2
- And address of the waste materials 3
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Cautions 4
- Specifications 4
- Caution 5
- Cautions 5
- Installation 5
- Safety instruction 5
- Warning 5
- Caution 6
- Cautions 6
- Use of air conditioner 6
- Warning 6
- Control panel 7
- Filter inside 7
- Indoor unit 7
- Outlet 7
- Parts and functions 7
- Operation hints 8
- Setting method 8
- Used than 8
- Cleaning of the unit 9
- Maintenance 9
- Maintenance at the end of application season 9
- Maintenance before beginning of application season 9
- Before asking for service check the following first 10
- Trouble shooting 10
- When unit is stopped it won t restart 10
- Installation manual of room air conditioner 11
- Tool necessary 11
- Fixing of the unit 12
- Installation manual of room air conditioner 12
- Installation manual of room air conditioner 13
- Piping connection of the indoor unit 13
- Electric wiring 14
- Installation manual of room air conditioner 14
- N l q p 14
- Process of wire connections 14
- Wiring connection 14
- Wiring of indoor unit 14
- A circuit breaker must be installed 15
- Cables for power supply connection and signals are prepared by the owner 15
- Connection parameters h05rn f 3g 1 1 mm signal parameters 15
- Dedicated electrical cable should be installed by a qualified technician in accordance with the state regulation for electrical engineering 15
- Electrical cables should be connected by ìyî method damaged or wornelectrical cable must be replaced by authorized after sales agents 15
- H05rn f 2x 0 5 1 mm shieded wire 15
- Installation manual of room air conditioner 15
- Power supply requirements 15
- The power plug should be connected as follows l for live line n for neutral line and for grounding 15
- The power source must be grounded 15
- The signal wire must be shielded wire 15
- Voltage single phase1ph 220 230v 50hz 15
- D flashes 14 times 16
- Resumable failures are marked with the others are not resumable failures resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds but the other failure code will disappear only after the unit starts up once again when failure occurs the unit only can receive off signal from the controller and when the unit is shut off the failure code will disappear 16
Похожие устройства
- Haier AF092XCEAA Сервис мануал
- Haier AF122XCEAA Инструкция по эксплуатации
- Haier AF122XCEAA Сервис мануал
- Haier AF142XCEAA Инструкция по эксплуатации
- Haier AF142XCEAA Сервис мануал
- Haier AB072XCEAA Сервис мануал
- Haier AB092XCEAA Сервис мануал
- Haier AB122XCEAA Сервис мануал
- Haier AB142XCEAA Сервис мануал
- Haier AB212XCEAA Инструкция по эксплуатации
- Haier AB212XCEAA Сервис мануал
- Haier AD072XLEAA Сервис мануал
- Haier AD092XLEAA Сервис мануал
- Haier AD122XLEAA Сервис мануал
- Haier AD142XLEAA Сервис мануал
- Haier AD212XLEAA Сервис мануал
- Haier AS072XCEAA Инструкция по эксплуатации
- Haier AS072XCEAA Сервис мануал
- Haier AS092XCEAA Инструкция по эксплуатации
- Haier AS092XCEAA Сервис мануал