9
Installation Manual of Room Air Conditioner
Place where it is easy to route drainage pipe
and outdoor piping.
Place ,away from heat source and with less
direct sunlight.
Place where cool and warm air could be
delivered evently to every corner of the room.
Place near power supply socket.Leave enough
space around the unit.
Place ,robust not causing vibration,where the
body can be supported sufficiently.
To prevent interference, place it at least 1m
away from other electric machines, such as
TV set, radio.
Installing
According to the dimension of the figure 2 shown,
nail two cement steel nails on the wall,Keep 2~3
mm out.then hang the back of the unit on them.
There must be no gap between the indoor unit
and wall.
Remove the front panel,then use two expansible
screws to fix the unit on the floor.As figure 3
shown.
Once refrigerant piping and drain piping connections
are complete,fill the gap of the throght hole with putty.
Attach the front panel and front grille in their orginal
positions once all connections are complete.
Tool necessary
1. Screw driver
2. Hacksaw
3. 70mm dia.hole core drill
4. Spanner(dia. 17,27mm)
5. Spanner(14,17,27mm)
6. Pipe cutter
7. Flaring tool
8. Knife
9. Nipper
10. Gas leakage detector or soap water
11. Measuring tape
12. Reamer
13. Refrigerant oil
Installation of indoor unit
selection of installation place
Fig1
330
617
Fig2
Fig3
more than
more than
more than
more than
Содержание
- Console type 1
- Oom air conditioner indoor units 1
- Operation and installation manual 1
- Table of contents 2
- And address of the waste materials 3
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Cautions 4
- Specifications 4
- Caution 5
- Cautions 5
- Installation 5
- Safety instruction 5
- Warning 5
- Caution 6
- Cautions 6
- Use of air conditioner 6
- Warning 6
- Control panel 7
- Filter inside 7
- Indoor unit 7
- Outlet 7
- Parts and functions 7
- Operation hints 8
- Setting method 8
- Used than 8
- Cleaning of the unit 9
- Maintenance 9
- Maintenance at the end of application season 9
- Maintenance before beginning of application season 9
- Before asking for service check the following first 10
- Trouble shooting 10
- When unit is stopped it won t restart 10
- Installation manual of room air conditioner 11
- Tool necessary 11
- Fixing of the unit 12
- Installation manual of room air conditioner 12
- Installation manual of room air conditioner 13
- Piping connection of the indoor unit 13
- Electric wiring 14
- Installation manual of room air conditioner 14
- N l q p 14
- Process of wire connections 14
- Wiring connection 14
- Wiring of indoor unit 14
- A circuit breaker must be installed 15
- Cables for power supply connection and signals are prepared by the owner 15
- Connection parameters h05rn f 3g 1 1 mm signal parameters 15
- Dedicated electrical cable should be installed by a qualified technician in accordance with the state regulation for electrical engineering 15
- Electrical cables should be connected by ìyî method damaged or wornelectrical cable must be replaced by authorized after sales agents 15
- H05rn f 2x 0 5 1 mm shieded wire 15
- Installation manual of room air conditioner 15
- Power supply requirements 15
- The power plug should be connected as follows l for live line n for neutral line and for grounding 15
- The power source must be grounded 15
- The signal wire must be shielded wire 15
- Voltage single phase1ph 220 230v 50hz 15
- D flashes 14 times 16
- Resumable failures are marked with the others are not resumable failures resumable failure will disappear when the failure is eliminated and its failure code will disappear automatically within 30 seconds but the other failure code will disappear only after the unit starts up once again when failure occurs the unit only can receive off signal from the controller and when the unit is shut off the failure code will disappear 16
Похожие устройства
- Haier AF142XCEAA Сервис мануал
- Haier AB072XCEAA Сервис мануал
- Haier AB092XCEAA Сервис мануал
- Haier AB122XCEAA Сервис мануал
- Haier AB142XCEAA Сервис мануал
- Haier AB212XCEAA Инструкция по эксплуатации
- Haier AB212XCEAA Сервис мануал
- Haier AD072XLEAA Сервис мануал
- Haier AD092XLEAA Сервис мануал
- Haier AD122XLEAA Сервис мануал
- Haier AD142XLEAA Сервис мануал
- Haier AD212XLEAA Сервис мануал
- Haier AS072XCEAA Инструкция по эксплуатации
- Haier AS072XCEAA Сервис мануал
- Haier AS092XCEAA Инструкция по эксплуатации
- Haier AS092XCEAA Сервис мануал
- Haier AS122XCEAA Инструкция по эксплуатации
- Haier AS122XCEAA Сервис мануал
- Haier AS142XCEAA Инструкция по эксплуатации
- Haier AS142XCEAA Сервис мануал