Haier AB072XCEAA [24/89] Btu indoor unit

Haier AD072XLEAA [24/89] Btu indoor unit
2. Pipe installations:
A1
A2
B1
B2
Gas pipe φ12.7
Liquid pipe
φ9.52
Liquid pipe
φ9.52
Gas pipe
φ12.7
21000BTU indoor unit
21000BTU indoor unit
Note: Though AU422XIEAA can match with the R407C free multi indoor unit, we do not
recommend so. Because that will not only lower the capacity,also the changing pipe
0010759292 will be required for all R407C free multi indoor unit when installation.
3. Outdoor wiring diagram should be changed as the following:
Coil of solenoid vavle A2
should be changed to
connected with CN29.
Coil of solenoid vavle B2
should be changed to
connected with CN23.
By-pass vavle on both
system A and system B
should be pulled out and
not connected.