Haier AD212XLEAA [67/89] Wiring diagram indoor

Haier AD212XLEAA [67/89] Wiring diagram indoor
OPTIONAL.
BR : BROWN
R : RED
Y/G: YELLOW/GREEN
W : WHITE
B : BLACK
SW1 and SW3 are used to choose the working
if the controller power on, the indoor unit run according to the state on the controller;
Power Supply
Ignore the state on the controller and power off
The controller is able to be controlled
Ignore the state on the controller and power off
if the controller power off, the indoor unit run in the auto mode
Working state of the wire controller
controller. The detailed information see the following:
0
1
1-CLOSE 0-OPEN
1 1
0
1
0
0
SW1 SW3
Outdoor Unit
Connect To
state of the
wire
NOTE
PARTS IN DASHED FRAMES ARE
NEGATIVE ION CONTACT
EARTH TERMINAL
WIRING DIAGRAM INDOOR
CN15
SW3
B
TRANSFORMER
BL
R
CN10
BL
CN2
CN11
R
CN18
CN3
SW1
CN20
BR
BR
Y/G
2(L)
1(N)
B
W
3
4
R
R
W
B
W
TERMINAL BLOCK
GND
Y/G
Open Close
CN5
CN17
CN16
CN14
CN13
CN12
CN1
CN19
SW2
CN4
DOWN
M
SENSOR
SENSOR
Fresh Air Motor
ROOM TEMP.
PIPING TEMP.
M
MOTOR
SWING
RECEIVER DISPLAY
EMERGENCY SWITCH
UP SWING MOTOR
M
GENERATER
NEGATIVE ION
FAN MOTOR
M
0010573506
9.4.1. Wiring Diagram for AS***XCEAA
Chff^j\bZe Abj Chg]blbhg^j
z 65 z
Detector
CN6

Содержание