Haier AV32NMVERA [138/531] To power supply

Haier AV32NMVERA [138/531] To power supply
.| FPYPUN KPHNYHTZ
SM
L
TR2
Wired Remote Controller
C
C
in accordance with the reality of the manufacture.
are the sequence number
2. is printed circuit board
1. is terminal block, the words on it
3.The Parts in the dashed frame are optional
(To O.D unit)
Wiring
Transmission
Q
A
B
TW2
P
A
B
1PH,220-230V,50Hz
TR1
TO POWER SUPPLY
TW1
N
L
Y/G
swing control board
W
W
W
W
W
2
3
4
5
5
4
3
2
1
1
5
5
44
3
3
22
1
1
5
5
44
3
3
22
1
1
11
33
CN3
CN1
3
3
1
1
33
44
55
66
1
2
1
2
CN5
5
CN6
3
4
5
4
3
11
22
CN4B
LED6
Y
Electronic Expansion Valve
Wired remote controller and I.D Unit
Transmission Lamp between
Forced-open lamp for indoor
Malfunction lamp for I.D unit
Transmission Lamp between
I.D and O.D unit
LED
LED1
LED4
LED3
LED5
LED2
R
G
R
R
G
GM1,2 Stepping motor
QO
Quiet Operation
RC
Room Card
GM1
GM2
W
WIRING DIAGRAM OF INDOOR UNIT
1
1
3
3
CN3
CN30
3
3
2
R
W
W
G
B
G
LED2LED1
9
CN21
6
7
8
5
4
3
2
1
LED5
10
33
11
33
22
2
1
2
1
1
1
23
23
2
1
2
1
CN22
TC1
TC2
TA
CN20
CN18
CN19
W
B
CN15
2
1
2
1
CN13
2
1
2
1
1
CN17
SW08
154
3
6
PCB
BL
W
W
1
2
2
54
3
6
6
6
3
45
3
45
2
2
1
1
CN33
CN34
2
1
2
1
1
2
1
2
CN26
4
4
CN24
1
1
2
3
2
3
CN23
2
1
1
2
FUSE
W
W
250VACT5A
LED6
SW03
SW02
SW07
SW01
CN31
5
3
3
5
1
1
CN1
CN10
G
Y
CN14
CN16
12
1
2
1
2
1
2
LED3LED4
W
R
1
1
2
2
3
3
6
6
1
1
PMV
CN9
5
5
2
2
1
1
2
3
2
3
4
4
between I.D and O.D unit
Wired controller address and
capacity setting of indoor unit
Transmission address setting
Transmission address setting
between I.D and central controller
make the local setting in accrodance with the following table
At the time of installation or after service inspection/repair
*Master/Slave Wired Remote controller and Wireless Remote Setting
Disconnected
R
CN7
BL
W
G
2
2
SM
CN6
RC
3
1
1
3
1
33
1
33
1
1
2
1
2
1
3
1
3
1
CN5
CN4
W
W
SW03
SW01
Dip Switch Function
Dip switch (8HP)
Dip switch (8HP)
SW02
Dip switch (8HP)
N
L
2
2
11
CN2
1
1
3
3
CN4A
W
54
54
CN11
Y/G
1
23
1
2
3
4
4
FM
6
6
45
45
CN8
5
3
11
3
5
7
7
Controller
Controller
Wired Remote
Wired Remote
(Control)
Null
Wired Controller
Wired Controller
/Dip switch
Mode
B.C connect with
ON
Slave Remote
Master Remote
Null
ON
A.B.C connect with
Terminal Block
CN23
CN30
SW08-6
CN21
Setting
Socket
Short conn ected
Short conn ected
Short connected
level control system
Transformer for swing PCB
Ambient Temperature Sensor
Gas Pipe Temperature Sensor
Electronic Expansion Valve
Liquid Pipe Temperature Sensor
Malfunction of O.D unit
improper setting SW02
improper setting SW03
Swing motor
Terminal block (Control)
Terminal block (Power)
Running Capacitor
Fan Motor
Transformer for power
TR2
TW2
TW1
PMV
TC1
TC2
FM
RC
Symbol
TA
TR1
Description
Address duplication
0A
10
Address duplication
20
9
09
between I.D and O.D unit
Malfunction of transmission
between rmote Controller
source sensor failure
Malfunction Contents
Indoor gas pipe temp.
Indoor ambient temp.
Indoor liquid pipe temp.
Malfunction of transmission
Malfunction of Drain
of LED5 on the
The Flash Times
LED on the
the PCB/Timing
and I.D unit
sensor TC2 failure
sensor TC1 failure
sensor TA failure
Code
2
1
3
7
8
5
6
4
EEPROM failure
Indoor twin energy
Ma lfun ctio n
03
07
08
04
06
05
02
01
Malfunction Code indication by Wired Remote Controller
Wireless Receiver
remote receiver
Disconnected
OFF
Connect to
A,B,C Null
Disconnected
Wireless Remote Controller
0010526531