Haier HSU-12HRA103/R2 [5/8] Operation
![Haier HSU-12HRA103/R2 [5/8] Operation](/views2/1819173/page5/bg5.png)
Operation
Set clock correctly before starting TIMER operation.
1.After unit starts, select your desired operation mode.
2.Press TIMER button to change TIMER mode. Every
time the button is pressed, display changes as follows:
Remote controller:
BLANK
TIMER ON TIMER OFF TIMER ON-OFF
Then select your desired TIMER mode (TIMER ON or
TIMER OFF or TIMER ON-OFF). " "or " "will flash.
3.Press TIME+ /TIME- button to set time.
It can be adjusted within 24 hours.
4.After setting correct time, press SET button to confirm
" "or" " on the remote controller stops flashing.
5.Cancel TIMER mode
Just press TIMER button several times until TIMER mode
disappears.
Hints:
After replacing batteries or a power failure happens, time
setting should be reset.
Remote controller possesses memory function,when use
TIMER mode next time, just press SET button after mode
selecting if time setting is the same as previous one.
According to the Time setting sequence of TIMER ON or
TIMER OFF, either Start-Stop or Stop-Start can be
achieved.
Timer On/Off On-Off Operation
CE
All the products are in conformity with the following
European provision:
- Low Voltage Directive 73/23/EEC
- Low Voltage Directive 2006/95/EC
-Electomagnetic CompatibilitY 89/336/EEC
-Electomagnetic CompatibilitY 2004/108/EC
ROHS
The products are fulfilled with the requirements in the
directive 2002/95/EEC of the European parliament and of
council on the Restriction of the use of Certain Hazardous
Substances in Electrical and Electronic Equipment (EU
RoHS Directive)
WEEE
DISPOSAL REQUIREMENTS:
Your air conditioning product is marked with this
symbol.This means that electrical and electronic
products shall not be mixed with unsorted
household waste. Do not try to dismantle the
system yourself : the dismantling of the air
EUROPEAN REGULATIONS
CONFORMITY FOR THE MODELS
1
1+2=
kg
R410A
2
kg
2=
1=
B
C
D
F E
kg
A
This product contains fluorinated greenhouse gases covered by
the Kyoto Protocol. Do not vent into the atmosphere.
Refrigerant type:R410A
GWP* value:1975
GWP=global warming potential
Please fill in with indelible ink,
• 1 the factory refrigerant charge of the product
• 2 the additional refrigerant amount charged in the field and
• 1+2 the total refrigerant charge
on the refrigerant charge label supplied with the product.
The filled out label must be adhered in the proximity of the product
charging port (e.g. onto the inside of the stop value cover).
A contains fluorinated greenhouse gases covered by the Kyoto
Protocol
B factory refrigerant charge of the product: see unit name plate
C additional refrigerant amount charged in the field
D total refrigerant charge
E outdoor unit
F refrigerant cylinder and manifold for charging
IMPORTANT INFORMATION REGA-
RDING THE REFRIGERANT USED
In accordance with the directive 2002/96/CE of the European
parliament, herewith we inform the consumer about the dis-
posal requirements of the electrical and electronic products.
conditioning system,treatment of the refrigerant, of oil and of
other part must be done by a qualified installer in accordance
with relevant local and national legislation. Air conditioners
must be treated at a specialized treatment facility for reuse,
recycling and recovery. By ensuring this product is disposed
of correctly, you will help to prevent potential negative cons-
equences for the environment and humen health. Please
contact the installer or local authority for more information.
Battery must be removed from the remote controller and dis-
posed of separately in accordance with relevant local and
nationl legislation.
Contains fluorinated greenhouse gases
covered by the Kyoto Protocol
5
Healthy airflow Operation
1.Press ON/OFF to starting
Setting the comfort work conditions.
2.The setting of healthy airflow function
1).Press the button of healthy airflow
, appears on the
display. Horizontal airflow sending.
Avoid the airflow
blows direct to the body.
2).Press the button of healthy airflow again, appears on
the displa
y
. Downward airflow sending.
Avoid the airflow
Note:
1.After setting the healthy airflow function, the position
grill is fixed.
4.In cooling and dry, using the air conditioner for a long
time under the high air humidity, condensate water may
occur at the grille .
3.The cancel of the healthy airflow function
Press the button of healthy airflow again,
the unit
goes on
working under the condition before the setting of healthy
airflow function.
Notice: Do not direct the flap by hand. Otherwise, the
grille will run incorrectly. If the grille is not run correctly, stop
for a minute and then start, adjusting by remote
controller.
blows direct to the body.
2.In heating, it is better to select the
3.In cooling, it is better to select the
mode.
mode.
Содержание
- Contents 1
- Operation manual 1
- Split type room air conditioner 1
- 2 3 1 6 7 5 2
- Actual indoor unit may vary from the one shown in the manual according to the product purchased 2
- Air purifying filter 2
- Anion generator 2
- Be sure that the loading is in line with the load the battery then put on the cover again 2
- Clock set 2
- Display board 2
- Emergency switch 2
- Extinguishing of led display board 2
- Health display 2
- Horizontal flap 2
- Indoor unit 2
- Inlet grille 2
- Light button control the lightening and the indoor 2
- Loading of the battery 2
- Outdoor unit 2
- Outlet 2
- Parts and functions 2
- Remote controller 2
- Signal sending display 2
- Temp display 2
- Timer on display sleep display 2
- Vertical blade 2
- Air conditioner is running under displayed fan speed when fan is set to auto the air conditioner automatically adjusts the fan speed according to room temperature 3
- Air flow direction adjustment 3
- At air outlet if all vertical louvers are right 3
- Base operation 3
- C if kept depressed it will decrease rapidly select a desired temperature 3
- C if kept depressed it will increase rapidly every time the button is pressed temp setting decrease 3
- Cautions 3
- Conditioner 3
- Continue to press the test operation 3
- Controller will automatically 3
- Display board remote controller note 3
- Emergency operation and test operation 3
- Fan nothing 3
- It is advisable not to keep horizontal flap at downward position for a long time in coolor dry otherwise condensate water might occur 3
- Move the vertical blade by a knob on air to adjust left and right direction referring to fig 3
- Operation 3
- Operation mode 3
- Operation starts with the air flow speed hi 3
- Pos pos pos 3
- Press button every time the button is pressed temp setting increase 1 3
- Press fan button for each press fan speed changes follows 3
- Press mode button for each press operation mode changes as follows remote controller 3
- Press on off on the remote controller unit starts 3
- Remote controller 3
- Set swing position 3
- Switch for more than 5 seconds after you hear the pi sound twice 3
- Temp temp 3
- Test operation switch is the same as emergency switch 3
- Use this switch in the test operation when the room 3
- When adjusting the flap by hand turn off the unit when humidity is high condensate water might occur adjusted to left or 3
- When restart after remote turning off the remote memorize the previous 3
- Your finger from the switch the cooling 3
- Healthy operation 4
- In heat mode 4
- Operation 4
- Power soft operation 4
- Sleep operation 4
- European regulations conformity for the models 5
- Healthy airflow operation 5
- Important information rega rding the refrigerant used 5
- Operation 5
- Timer on off on off operation 5
- For smart use of the air conditioner 6
- Maintenance 6
- Replacement of air purifying filter 6
- Use the timer effectively 6
- Caution 7
- Cautions 7
- Please call sales service shop for the installation do not attempt to install the air conditioner by yourself because improper works may cause electric shock fire water leakage 7
- Warning 7
- Before asking for service check the following first 8
- Cautions 8
- Specifications 8
- The machine is adaptive in following situation 8
- Trouble shooting 8
- X 0 15 0 17 8
Похожие устройства
- Haier HSU-18HRA103/R2 Инструкция по эксплуатации
- Haier HSU-09RC03/R2(DB) Инструкция по эксплуатации
- Haier HSU-12RC03/R2(DB) Инструкция по эксплуатации
- Haier HSU-18RC03/R2(DB) Инструкция по эксплуатации
- Haier HSU-22RC03/R2(DB) Инструкция по эксплуатации
- Haier HSU-119M07 Инструкция по эксплуатации
- Haier HSU-129M07 Инструкция по эксплуатации
- Haier HSU-189M07 Инструкция по эксплуатации
- Haier HSU-229M07 Инструкция по эксплуатации
- Haier HW-09CV03 Инструкция по эксплуатации
- Haier HW-12CV03 Инструкция по эксплуатации
- LEO LKJ-601PA Инструкция по эксплуатации
- LEO LKJ-601PA Сертификат
- LEO LKJ-601PA Каталог
- LEO LKJ-601PA5 Инструкция по эксплуатации
- LEO LKJ-601PA5 Сертификат
- LEO LKJ-601PA5 Каталог
- LEO LKJ-801PA Инструкция по эксплуатации
- LEO LKJ-801PA Сертификат
- LEO LKJ-801PA Каталог