Haier HC4291VAR [15/16] Color codes bk black bl blue gy gray br brown gr green or orange pu purple rd red vi violet wh white yl yellow
![Haier HC3091VAR [15/16] Color codes bk black bl blue gy gray br brown gr green or orange pu purple rd red vi violet wh white yl yellow](/views2/1820222/page15/bgf.png)
5
PU
ELECTRIC HEATER KIT
RD
BL
Air Conditioner Wiring Diagram
1) Confirm system selection. Optional components may be field or factory installed.
2) If LPS and/or HPS not installed or removed, a jumper wire must be present across circuit for system to operate.
3) For proper system operation, consult indoor unit and outdoor unit installation instructions to confirm system match up and blower speed selection.
4) Alternate double pole contactor used on some systems.
5) Only one start assist method to be used at a time, consult outdoor unit installation instructions for application information. Use only factory approved accessories.
6) Optional OFM components may connect capacitor common and motor common, for reciprocating compressor there may have crankcase heater consult outdoor unit installation
instructions for details.Select the running capacitor(one or dual)and connect.If IFM or OFM only have one capacitor wire,connect Com wire to capacitor.
7)
RD
24VAC COMMON
COMPRESSOR
BL
YL
208/230V
60Hz 1PH
C
BL
BL
YL
YL
Y
2
YL
P3
P2
P1
6
RD
R
L1
GND
L2
BK
BK
WH
C
S
CC
4
RD
YL
2
1
NC
Optional
Low & High
Pressure
Switches
LPS
HPS
Compressor
Protect 3 Min.
Time Delay
BCAP
RD-LO
RD
L2
RD
OR
BK-HI
M
IBM
3
GR
PU
L1
BK
BK
R
S
BR
BR
208
COM
BL
R
TRAN
COM
230
7
BL
5
3
RD
NO
GR
8
6
4
OFM
M
BK
PU
PU
BR
6
S
R
BR
L1
L2
GND
60Hz 1PH
208/230V
WH
BK
BCR
1
BK
2
RD
BRK
BK
L2
RD
RD
FL
L1
BK
FL
USE COPPER CONDUCTORS ONLY
WARNING CABINET MUST BE PERMANENTLY GROUNDED
AND ALL WIRING TO CONFORM TO I.E.C.,N.E.C.,C.E.C.,
C.L.C. AND LOCAL CODES AS APPLICABLE.
REPLACEMENT WIRE MUST BE THE SAME GAGE AND
INSULATION TYPE AS ORIGINAL WIRE.
COMPONENT CODES
BCR - BLOWER CONTROL RELAY
BCAP - RUN CAPACITOR BLOWER MOTOR
CC - COMPRESSOR CONTACTOR
CCH - CRANKCASE HEATER (OPTIONAL)
CHS - CRANKCASE HEATER SWITCH (OPTIONAL)
CMPR - COMPRESSOR
HPS - HIGH PRESSURE SWITCH
LPS - LOW PRESSURE SWITCH
IBM - INDOOR BLOWER MOTOR
OFM - OUTDOOR FAN MOTOR
RCAP - RUN CAPACITOR COMPRESSOR
RVS - REVERSING VALVE SOLENOID
STCAP - START CAPACITOR (OPTIONAL)
STRLY - START RELAY (OPTIONAL)
STRTH - START THERMISTOR (OPTIONAL)
TRAN - TRANSFORMER
230/208 SELECTABLE
R
H
S
-
1
COLOR CODES
BK - BLACK BL - BLUE GY - GRAY
BR - BROWN GR- GREEN OR - ORANGE
PU - PURPLE RD - RED VI - VIOLET
WH - WHITE YL - YELLOW
INDOOR FAN CONTROL
HEAT CONTROL
C
R
Y
W
G
WH
C
BL
G
W2
BL
BR
W
CA
RHS-2
TS
ON
AUTO
LED
F
A
N
COOL
OFF
HEAT
S
W
-
2
HA
COOL
OFF
HEAT
S
W
-
1
LINE VOLTA GE
FACTORY STANDARD
FIELD INSTALLED
OPTIONAL
LOW VOLTAGE
FACTORY STANDARD
FIELD INSTALLED
OPTIONAL
WH
PU
2
2
BK
1
1
RD
3
3
4
BL
3
5
BR
5
5
BL
4
4
7
BR
6
6
6
WH
BK
OPTIONAL
BK
RD
RD
RD
RD
TL
TL
RESISTANCE
HC18-6091VAR
When supplying power for outdoor unit,the black line is for neutral line and white line for live line.
12
Содержание
- Central air conditioner 1
- Installation operation manual 1
- Warning 2
- Table of content 3
- Introduction 4
- Nomenclature for model number 4
- Specification 4
- Model hc18 6091var table 1 5
- Equipment protection from environment 6
- Installation 6
- Unit inspection 6
- Do not allow the vapor line and liquid line to touch together this would cause an undesirable heat transfer resulting in capacity loss and increased power consumption 8
- Figure 3 8
- Line insulation suction line requires insulation in order to prevent condensation from forming on the piping and to prevent heat gain caused by surrounding air generally 3 8 wall thickness of armflex or equivalent is satisfactory in severe application hot high humidity areas greater thickness may be required apply the line insulation by sliding it on the sealed tuing before cutting and making connections 8
- Liquid line does not necessarily need insulation however if they are exposed to high ambient temperatures i e kitchen boiler rooms hot attics rooftop surface then they should be insulated make sure to use the proper size tubing for the liquid line to prevent liquid refrigerant flashing to a vapor within the liquid line 8
- Electrical wiring 11
- System startup 12
- Miscellaneous 13
- Operation 13
- Air conditioner wiring diagram 15
- Color codes bk black bl blue gy gray br brown gr green or orange pu purple rd red vi violet wh white yl yellow 15
- Component codes bcr blower control relay bcap run capacitor blower motor cc compressor contactor cch crankcase heater optional chs crankcase heater switch optional cmpr compressor hps high pressure switch lps low pressure switch ibm indoor blower motor ofm outdoor fan motor rcap run capacitor compressor rvs reversing valve solenoid stcap start capacitor optional strly start relay optional strth start thermistor optional tran transformer 230 208 selectable 15
- Compressor 15
- Compressor protect 3 min time delay 15
- Ha cool off heat 15
- Hc18 6091var 15
- L2 gnd 15
- Line voltage factory standard field installed optional low voltage factory standard field installed optional 15
- Optional low high pressure switches 15
- Use copper conductors only warning cabinet must be permanently grounded and all wiring to conform to i e c n e c c e c c l c and local codes as applicable replacement wire must be the same gage and insulation type as original wire 15
- Vac common 15
Похожие устройства
- Haier HC6091VAR Инструкция по эксплуатации
- Haier HC2491VAR Инструкция по эксплуатации
- Haier HC3691VAR Инструкция по эксплуатации
- Haier HC4891VAR Инструкция по эксплуатации
- Onkyo LS-B50 Black Инструкция по эксплуатации
- Onkyo LS-B50 Black Руководство пользователя
- Haier H2SM-18HV03(B) Инструкция по эксплуатации
- Haier HSU-07HV03(B) Инструкция по эксплуатации
- Haier HSU-14HV03(B) Инструкция по эксплуатации
- Haier HSU-10HV03(B) Инструкция по эксплуатации
- Haier HSU-12HV03(B) Инструкция по эксплуатации
- Haier AS112BHAHA Инструкция по эксплуатации
- Haier AS072AHAHA Инструкция по эксплуатации
- Haier AS142AHAIA Инструкция по эксплуатации
- Haier AS102AHAHA Инструкция по эксплуатации
- Haier AU182BFAHA Инструкция по эксплуатации
- Haier AU072ACAHA Инструкция по эксплуатации
- Haier AU142AKAHA Инструкция по эксплуатации
- Haier AU122AKAIA Инструкция по эксплуатации
- Haier HSM09HS03/R2(DB) Инструкция по эксплуатации