Haier AU122AKAIA [4/29] Specifications
Содержание
- Inverter room air conditioner 1
- No 010542640 1
- Operation manual 1
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Safety instructions and warnings 3
- Specifications 4
- Caution 5
- Installation 5
- Warning 5
- A caution 6
- A warning 6
- Control panel 8
- Remote controller 8
- About the display temperature difference 9
- Brief introduction to health operation 11
- Remote controller 11
- Auto operation 12
- Control panel 12
- Control panel 13
- Cool operation 13
- Ll llll lllh 13
- Remote controller 13
- Dry operation 14
- Remote controller 14
- 11 f1111 1111 16
- Heat operation 16
- Air flow direction adjustment 17
- Left and right air flow direction 17
- Status display of air sending direction 17
- Up and down air flow direction 17
- Sleep operation 18
- 300 300 300 19
- Remote controller 19
- Set clock correctly before starting timer operation 19
- Remote controller 20
- Set clock correctly before starting timer operation 20
- Control panel 21
- Power operation 21
- Power soft operation 21
- Soft operation 21
- All dllll 22
- Fan speed display 22
- Pdflllll 22
- Remote controller 22
- Emergency operation 23
- Emergency operation and test operation 23
- Notejn test operation the main unit only receive the stoping signal 23
- Removal of the restriction of emergency or test operation 23
- Test operation 23
- Cleaning of the unit 24
- Maintenance at the end of application season 25
- Maintenance before beginning of application season 25
- Fixing and replacing the air filter 26
- Attaching ion dust collector 27
- Better use of air conditioner 28
- Before asking for service check the following first 29
Похожие устройства
- Haier HSM09HS03/R2(DB) Инструкция по эксплуатации
- Haier 2HUM18H03/R2(DB) Инструкция по эксплуатации
- Haier HSM12HS03/R2(DB) Инструкция по эксплуатации
- Haier HSU-09HV04/R2(DB) Инструкция по эксплуатации
- Vitek VT-3531 SR Руководство пользователя
- LG F2M5NS3W Инструкция по эксплуатации
- LG F4M5TS3W Инструкция по эксплуатации
- LG F4M5TS6W Инструкция по эксплуатации
- LG F2H6HS0B Инструкция по эксплуатации
- LG F2M5WS4W Инструкция по эксплуатации
- LG F2J6TN0W Инструкция по эксплуатации
- LG F2J5NS6W Инструкция по эксплуатации
- LG F2M5HS7S Инструкция по эксплуатации
- LG F2M5HS4W Инструкция по эксплуатации
- LG F2M5HS6W Инструкция по эксплуатации
- LG F2J5HS6S Инструкция по эксплуатации
- LG F2J5HS6W Инструкция по эксплуатации
- LG F2V5HS0W Инструкция по эксплуатации
- LG F2V5HS9B Инструкция по эксплуатации
- LG F2V5HS2S Инструкция по эксплуатации
Do not obstruct or cover the ventilation grille of the air conditioner Do not put fingers or any other things into the inlet outlet and swing louver 7 The waste battery should be disposed properly 8 The appliance is not intended for use by young children or infirm persons without supervision Do not allow children to play with the air conditioner In no case should children be allowed to sit on the outdoor unit 9 Young children should be supervised to ensure that they do not play with the appliance Specifications 10 The breaker of the air conditioner should be all pole switch 25A and the distance between its two contacts should be not less than 3mm only for some models The refrigerating circuit is leak proof The machine is adaptive in following situation 11 The appliance must be installed on strong enough supporter 1 Applicable ambient temperature range Indoor Cooling 12 The wiring diagram is attached inside the machine Maximum D B W B 32 C 23 C Minimum D B W B 18 C 14 C 13 If the fuse on the outdoor unit is broken please change it with the type of T 20A 250V Maximum D B W B 43 C 26 C Outdoor Minimum D B 18 C Indoor Maximum D B Minimum D B Outdoor Maximum D B W B 24 C 18 C Minimum D B 15 C Heating 27 C 15 C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person in order to avoid hazard The type of connecting wire is H05RN F or H07RN F H2SM 18HV03 B HSU 07HV03 B HSU 10HV03 B 3G1 5mm2 1x0 75mm2 HSU 14HV03 B HSU 12HV03 B 3G2 0mm2 1x1 0mm2 3 If the fuse on PC board is broken please change it with the type of T 3 15A 250V 4 The distance between the indoor unit and the floor should be more than 2m 5 The wiring method should be in line with the local wiring standard 6 After installation the power plug should be easily reached 2