Remote Control:
There is a telecommunication interface for remote control on the control panel of the indoor unit.
After the peripheral equipment have been installed in accordance with the instruction manual of the
selected remote control detector, the air conditioner will be computerized and controlled from a far-
away place.
When the air conditioner does not operate properly after you have checked the above mentioned
items or when the following phenomenon is observed, stop the operation of the air conditioner
and contact your sales dealer.
The fuse or breaker often shuts down.
Water drops off during cooling operation.
There is a irregularity in operation or abnormal sound is audible.
When the CHECK lamp flickers, an irregularity has occurred in the air conditioner.
Flickering
E0
Note:
This unit has a function of automatic restart system after recovering power stoppage. Please contact the sales
dealer if it is not required.
The trouble
of the
drainage
system
Content
of defect
E1
The trouble
of the room
temp. sensor
E2
The trouble
of the pipe
temp. sensor
E3
The trouble
of the outdoor
temp. sensor
E4
The trouble of
the outdoor
pipe temp.
sensor
E5
The trouble of
the overload
current
E6
The trouble of
the low pressure
pressure of pipe
E8
The trouble of the
main control board
communication
E9
The trouble of the
main control board
outdoor board
communication
Malfunction judgement
Note: Air conditioner has installed detector,in order to add group control function,Can refer to
Centralized Controller installation and operation manual.
Power Failure Compensation (to be applied for a necessary situation):
Setting Method: When the remote controller is on (excluding timer mode and fan mode),
press the "Sleeping" button on the remote controller 10 times within 5
seconds, and after the buzzer rings 4 times, the air conditioner will enter
the state of power failure compensation.
Cancel Method: Press the "Sleeping" button on the remote controller 10 times within 5
seconds, and after the buzzer rings 2 timer, the power failure compensation
mode will be cancelled.
Notes: When a power failure suddenly occurs during the air conditioner is working after the power
failure compensation is set, if the air conditioner will not be used for a long time, please cut off the
power supply to prevent its operation from being resumed after the power is supplied again, or press
the "Switch On/Off" button after the power comes again.
After the power failure compensation is set, if power failure suddenly occurs while the air conditioner
is working, it will resume the previous working state when the power is supplied again.
Содержание
- Cassette air conditioner 1
- Operation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Carefully read the following information in order to operate the airconditioner correctly 5
- Cautions 5
- Safety cautions 5
- Warning 5
- Cautions 6
- Caution 7
- Cautions 7
- Installation 7
- Location 7
- Operating noise 7
- Warning 7
- Wiring 7
- Buttons and display of the wire controller 8
- Fan speed 8
- Introduction to spare parts 8
- Operation 8
- Introduction to spare parts 9
- Air inlet 10
- Air outlet 10
- Compressor 10
- Indoor unit 10
- Inside of unit 10
- Introduction to spare parts 10
- Outdoor unit 10
- 1 unit start 11
- 2 select operation mode 11
- 4 unit stop 11
- Enjoy yourself by just a gentle press 11
- Fan operation 11
- Guide to operation 11
- The air conditioner has the function of power failure resume 11
- 1 unit start 12
- 2 select operation mode 12
- 3 select temp setting 12
- 4 fan speed selection 12
- 5 unit stop 12
- Auto run cool heat and dry operation 12
- Guide to operation 12
- Recommendations 12
- Use cool in summer use heat in winter use dry in spring autumn and in damp climate 12
- Guide to operation 13
- Timer on off 13
- Timer operation 13
- To cancel timer mode 13
- 1 after unit start select your desired operation mode 14
- 2 press timer button to change timer mode 14
- 3 time setting for timer on 14
- 4 time confirming for timer on 14
- 5 time setting for timer off 14
- 6 time confirming for timer off 14
- Guide to operation 14
- Timer on off 14
- To cancel timer mode 14
- Comfortable sleep 15
- Guide to operation 15
- In cooling dehumidifying mode 15
- In heating mode 15
- Adjusting up down air flow direction 16
- Avoid direct air flow to the body for many hours avoid downward blowing opera tion of cooling mode for many hours do not touch the swing louver during swing operation 16
- Caution 16
- Guide to operation 16
- Guide to operation 17
- Malfunction judgement 17
- Clean air filter 18
- Maintenance 18
- Open inlet grill 18
- Open two othooks 18
- Clean air filter 19
- Clean inlet grill 19
- Close inlet grill 19
- Controller 19
- Maintenance 19
- Press the filter signal return key on the 19
- Clean inlet grill 20
- Clean outlet and shell 20
- Dismantle and install swing plate 20
- Maintenance 20
- At the beginning 21
- Call technician clean air filter and shell 21
- Call technician to clean air filter and shell 21
- Check the following items 21
- Dismantle and install swing plate 21
- In fine days go on with blowing for half a day to make inner part of conditioner dry 21
- Install swing plate 21
- Maintenance 21
- Maintenance at the beginning and closing of the applying seasons 21
- Turn off power supply 21
- Turn on power 21
- When not in use for a long time 21
- Symptom reason 22
- The following symptoms are not faults 22
- Trouble shooting 22
Похожие устройства
- Haier HBU-28HD03/R1 Инструкция по эксплуатации
- Haier HBU-36HC03/R1 Инструкция по эксплуатации
- Dialog Gan-Kata KGK-16U Руководство пользователя
- Haier HBU-42HD03/R1 Инструкция по эксплуатации
- Dialog Gan-Kata KGK-17U Руководство пользователя
- Haier AX082ACNAA Инструкция по эксплуатации
- Haier AU082AJNAA Инструкция по эксплуатации
- Haier HSM-08C03/R1 Инструкция по эксплуатации
- Dialog Gan-Kata KGK-45U Руководство пользователя
- Haier HM-07C03 Сервис мануал
- Haier HM-07C03 Инструкция по эксплуатации
- Dialog Katana KK-ML17U Руководство пользователя
- Dialog Standart KS-020P Руководство пользователя
- Dialog Standart KS-020U Руководство пользователя
- Philips SPZ5000 Краткое руководство
- Philips SPZ5000 Руководство пользователя
- Hotpoint-Ariston 7OFK 637J RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 637J X RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 637J C RU/HA Инструкция по эксплуатации
- Hotpoint-Ariston 7OFK 638J RU/HA Инструкция по эксплуатации