Haier AB182FCBIA [7/11] Installation procedures
![Haier AB092FCBIA [7/11] Installation procedures](/views2/1821616/page7/bg7.png)
6
Below are listed four kinds of Safety Cautions and Suggestions:
Be sure to conform with the following important Safety Cautions.
The Safety Cautions should be at hand so that they can be checked at any time when needed.
If the air conditoner is transferred to the new user, this manual should be as well transferred to the new
user.
Safety Cautions
Incorrect operations may result in severe consequences of death or serious injures.
WARNING:
Incorrect operations may result in injures or machine damages; in some cases may
cause serious consequences.
CAUTION :
: It must be strictly prohibited where marked with ì Prohibited î, otherwise may result in
machine damages or endanger the userípersonal safety.
This information can ensure the correct operation of the machine.
INSTRUCTION:
Carefully read the following information in order to operate the air conditioner correctly.
WARNING
If any abnormal phenomena are found (e.g.
smell of firing),please cut off the power supply
immediately, and contact the dealer to find outí
the handling method.
When need maintenance and
repair,call dealer to handle it.
Donít put figures or any other
things into the inlet/outlet and
swing louver while the conditi-
oner is in operation
Call the dealer to take measures to prevent the
refrigerant from leaking.
Switch
off
In such case,to continue using
the air conditioner will damage
the conditioner,and may cause
electrical shock or fire hazard.
Incorrect maintenance and repair
may cause water leak,
electrical shock and fire hazard.
Because the high-speed fan
is very dangerous and may cause
injures.
The leaked refrigerant over certain density may
cause oxygen deficient.If the air conditioner is
installed in a small room be sure to take measure
in order to prevent suffocation accident even in
case of refrigerant leakage
When air conditioner is removed and reinstalled
dealer should be responsible for them.
Incorrect installation may cause water leaking,
electrical shock and fire hazard.
Donít dismantle the outlet of the outdoor unit.
The exposure of fan is very
dangerous witch may harm
human beings.
After a long time use of air conditioner the base
should be checked for any damages.
If the damaged base is not
repaired, the unit may fall
down and cause accidents.
15
6. Installation of Ornament Panel
Install ornament panel on indoor unit
(1) Check whether indoor unit is horizontal with leveler or polythene pipe filled with water , and
check that the dimension of the ceiling opening is correct. Take off the lever gauge before install
the ornament panel.
(2) Fasten the screws to make the height difference between the two sides of indoor unit less than
5mm.
(3) First fix it with screws temporally.
(4) Fasten the two temporally fixing screws and other two, and tighten the four screws.
(5) Connect the wires of synchro-motor.
(6) Connect the wire of signal.
(7) If no response of remote controller,check whether the wiring is correct,restart remote controller
10 seconds after shut off power supply.
Limits of panel board installation
(1)Install the panel board in the direction shown in
the figure.
(2)The incorrect direction will result in water leakage,
meanwhile swing and signal receiving are displayed
that cannot be connected.
Installation Procedures
Содержание
- Cassette type air conditioner 1
- Contents 1
- Indoor unit operation installation manual 1
- Cautions 2
- Disposal of the old air conditioner 2
- Disposal of the packaging of your new air conditioner 2
- Cautions 3
- Installation procedures check and test run 3
- Other instructions 3
- Specifications 3
- If fan speed in auto mode it will automatically lower when the room temperature close to the setting temperature in cooling mode 4
- If restart the unit immediately after stopping the compressor will start only 3 minutes later to protect the machine 4
- In dry mode fan speed will be automatically varied 4
- In heating mode the compressor stops when the room temperature at setting temperature and fan turns into low speed or stops 4
- Main points of operation 4
- Minute protection function 4
- Operation of air conditioner 4
- Please check the following things about your air conditioner before making a service call 4
- Remote control 4
- There is a telecommunication interface for remote control on the control panel of the indoor unit after the peripheral equipment have been installed in accordance with the instruction manual of the selected remote control detector the air conditioner will be computerized and controlled from a far away place 4
- Trouble shooting 4
- Unit fails to start 4
- Variation of fan speed 4
- When the environmental humidity is great water maybe dripped from the air outlet in cooling or drying mode 4
- Defrosting function 5
- In heating mode the indoor fan will not run immediately after the unit starts to prevent the cool air blowing off 5
- In heating mode when frost formed on the outdoor heat exchanger the air conditioner will automatically defrost a few minutes during defrosting both indoor and outdoor fan will stop running when defrosting finished air condi tioner will automatically back to running 5
- Main points of operation 5
- Power failure compensation to be applied for a necessary situation 5
- Prevent cool air blowing off 5
- Remote controller units please press the remote controller botton code to choose the program of code b 5
- The air conditioner absorbs heat form outside and releases inside when in heating mode therefore the outside environmental temperature will affect heating effects 5
- The followings are not malfuncition 5
- Trouble shooting 5
- Air filter inside of the inlet grille 6
- Air inlet grille 6
- Electrical box 6
- Indoor unit 6
- Installation procedures 6
- Name of each part 6
- Operating control panel 6
- Piping connection 6
- Swing louver air flow direction can be adjusted by using the swing button on the remote controller 6
- Below are listed four kinds of safety cautions and suggestions 7
- Carefully read the following information in order to operate the air conditioner correctly 7
- Caution 7
- Install ornament panel on indoor unit 7
- Installation of ornament panel 7
- Installation procedures 7
- Instruction 7
- Limits of panel board installation 7
- Safety cautions 7
- Warning 7
- Cautions for the water drainage lifting pipe 8
- Installation of water drainage pipe 8
- Installation procedures 8
- Safety cautions 8
- Warning 8
- After installation on the ceiling 9
- Caution 9
- Clean indoor unit 9
- Clean the air filter 9
- Clean the unit 9
- In the case of ceiling already exists 9
- Installation of indoor unit 9
- Installation procedures 9
- Lug two corners of the filter at the same time pull off the filter 9
- Maintenance 9
- Installation preparation 10
- Installation procedures 10
- Maintenance 10
- Post season care 10
- Pre season care 10
- Seasonal reserve 10
- Selection of installation place 10
Похожие устройства
- Haier AB182FCBIA Сервис мануал
- Haier AE072FCBKA Сервис мануал
- Haier AE092FCBKA Сервис мануал
- Haier AE122FCBKA Сервис мануал
- Haier AE142FCBKA Сервис мануал
- Haier AE182FCBKA Сервис мануал
- Haier AE242FCBKA Сервис мануал
- Haier AS072FCBHA Сервис мануал
- Haier AS092FCBHA Сервис мануал
- Haier AS122FCBHA Сервис мануал
- Haier AS142FCBHA Сервис мануал
- Haier AS182FCBHA Сервис мануал
- Haier AU242FHBIA Сервис мануал
- Haier AU482FIBIA Сервис мануал
- Haier AU48NFIBJA Сервис мануал
- Haier AU282FHAIA Сервис мануал
- Haier AU342FHAIA Сервис мануал
- Haier AU522FIAKA Сервис мануал
- Haier AU52NFIAKA Сервис мануал
- Haier AU60NFIAKA Сервис мануал