Haier AE212FCAKA [46/174] Indoor unit wiring diagram

Haier AS062FMAHA [46/174] Indoor unit wiring diagram
in the diagram,gas pipe temp. sensor
、liquid pipe temp. sensor、indoor fan motor
、transformer are necessary parts;wired
controller、receive display、electronic
expansion valve、float switch、pump motor
、swing motor are parts matched with the
model(combined usage);auxiliary electric
heater、refresh air fan motor、negative ion
generator、high pressure accumulator are
optional parts for health and comfort
(combination usage arbitrarily).wired
controller and receive display only can
choose one at will.
the unit with remote controller is matched
with receive display:
1.ceiling concealed type:CN11 must be
short connected with a jump wire;
2.duct type:connected with float
switch and pump motor;
3.cassette type:connected with float
switch、pump motor and swing motor;
4.cabinet type:CN11 must be short
connected with a jump wire,connected with
swing motor;
the unit with wired controller(equipped
with wired controller,can make remote
operation on wired controller with remote
controller such as YR-H39):
short connect CN15、CN17 together with
jump wire,other parts are as the same as
remote control unit.。
bulit-out electronic expansion valve
setting(MP3):CN23 is cut circuit,CN25 is
connected with electronic expansion valve
communication,and the electronic expansion
valve box(MP3) control indoor refrigerant
flow.
built-in electronic expansion valve
setting:CN23 is short connected with a jump
wire,CN6 is connected with electronic
expansion valve,and indoor unit control
refrigerant flow itself。
yellow/green
SW1
RL7
RL6
RL5
RL4
RL3
RL2
RL1
wired controller
FUSE
T15A/250VAC
Must connect electronic expansion valve
box power and communication from
corresponding indoor,wiring sequence must
correspond with the label
respectively,other wise, will cause PCB
of indoor and electronic expansion valve
box not work and damaged.
outdoor
communication
electronic
expansion valve
box power supply
and communication
indoor power
NOTE:
indoor fan motor
negative ion generator or high
pressure accumulator
resumeable heat
protector
80℃,10A/250VAC
only applicable for unit with
auxiliary electric heater
one-off heat
protector
105℃,10A/250VAC
indicator(running-red)
indicator(timer-yellow)
indicator(power-green)
LED3
LED2
LED1
auxiliary heater
emergency switch(ON/OFF)
health function module
relay
pump motor relay
swing motor relay
auxiliary eletric
heater relay
indoor fan motor
low-speed relay
indoor fan motor
Mid-speed relay
indoor fan motor
High-speed relay
About control board outer connector:
NOTE:the dashed "---"in indoor controll
board is PCB inner wiring.
LED1
CN2
CN1
receive display
liquid pipe temp.
sensor
gas pipe temp.
sensor
LED3 LED2
SW1
ambient temp.
sensor
1
float switch
CN16
FUSE
3.15A/250VAC
swing motor
1
indoor control board
3
fan capacitor
redred
DC
A
B
2
1
1
2
CN10CN1
7
65
CN14
connector
earthing
M
pump motor
MM
CN4
23
11
234
CN12CN7
23
1
32
RL6
2434
41
3
2
1
RL7
8
5
6
879
10
9 1075
6
CN15
1
2
CN13
RL4
RL5
RL2RL3
black red red
CN19
CN20
CN3
12
CN22
RL1
brown
white
CN25
CN18
Indoor unit wiring diagram
2
CN9
32
1
2
blue
1
CN11
serial
1
2
black
342
1
65
1
324
CN6
CN5
2
unit code setting
CN23
1
2
3
CN17
1
M
electronic
expansion valve
M
refresh air fan
motor
transformer
CN8
1
23
blue blue
AE072FCAKAAE092FCAKAAE122FCAKAAE182FCAKAAE212FCAKAAE242FCAKA