Haier AC142ACBIA [4/25] Cautions
![Haier AU182AFBJA [4/25] Cautions](/views2/1821724/page4/bg4.png)
Cautions
D
L
K1
Temperature and Humidity Range
If the air conditioner is used under higher
temperature condition than those listed,
the built-in protection circuit may operate
to prevent internal circuit damage. Also,
during Cooling and Dry modes, if the unit
is used under conditions of lower
temperature than those listed above, the
heat-exchanger may freeze, leading to
water leakage and other damage.
Do not use this unit for any other purposes
except for the Cooling, (*)Heating,
Dehumidifying, and air-circulation of
rooms in ordinary dwellings.
The wiring method should be in line with
the local wiring standand.
The waste battery should be disposed
properly.
If the fuse on PC board is broken, please
change it with the type T 3.15A/250V.
Cooling
Heating
Indoor
outdoor
Rated Maximum Minimum
27 32 18
19 23 14
35 43 -5
24 26 --
20 27 15
14.5 -- --
7 24 -7
6 18 --
DB C
WB C
DB C
WB C
Indoor
outdoor
DB C
WB C
DB C
WB C
When installation in under ceiling, dial
switch "K1" in the PC board to "D"
position. When installation in floor
console, dial switch to "L" position (Brand
new unit is in "D" position).
For this model, the all-pole discon-rexion
connection method should be applied in
the power supply.
Such means for disconnection must be
incorporation in the fixed wiring.
All electrical repairs must be carried out
by qualified electricians. Inadequate repairs
may result in a major source of danger for
the user of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by
piercing or perforating the air conditioner's
tubes with sharp or pointed items, crushing
or twisting any tubes, or scraping the
coatings off the surfaces. If the refrigerant
spurts out and gets into eyes, it may result
in serious eye injuries.
Do not obstruct or cover the ventilation
grille of the air conditioner. Do not put
fingers or any other things into the
inlet/outlet and swing louver.
Do not allow children to play with the air
conditioner. In no case should children be
allowed to sit on the outdoor unit.
Specifications
The refrigerating circuit is leak-proof.
Содержание
- Convertible type air conditioner 1
- Operation installation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Caution 5
- Danger 5
- Safety precautions 5
- Warning 5
- Automatic operation 6
- Cooling type 6
- Features and functions 6
- Heat cool type 6
- Mildew resistant filter 6
- Wireless remote control unit 6
- Fig indoor unit 7
- Fig outdoor unit 7
- Name of parts 7
- Caution 8
- Cleaning and care 8
- Cleaning the air filter 8
- Followings are not problems 9
- Trouble shooting 9
- Air conditioner won t start 10
- Before ask for services please first check your unit against the following 10
- Poor cooling 10
- Poor cooling or heating 10
- Trouble shooting 10
- Operation tips 11
- Caution 12
- Installation 12
- Location 12
- Operating noise 12
- Warning 12
- Wiring 12
- Installation tools 13
- Standard parts 13
- Installation procedures 14
- Under ceiling 14
- Warning 14
- Installation procedures 15
- Outdoor unit 15
- Warning 15
- A floor console type 16
- Drilling for piping 16
- Installation procedures 16
- Preparing indoor unit installation 16
- Remove the intake grill 16
- B under ceiling type 17
- Drain hose 17
- Drain pan 17
- Installation procedures 17
- Installing drain hose 17
- Insulation drain hose 17
- Nylon fastener 17
- Ok no no 17
- Using the installation template drill holes for piping and anchor bolts for holes fig 0 17
- Caution 18
- Drilling for piping 18
- Drilling holes for anchor bolts and installing the anchor bolts 18
- Fig 16 18
- Fig 17 18
- Hex bolt 18
- Installation procedures 18
- Installing brackets 18
- To 13mm indoor unit 18
- Connecting the piping 19
- Fig 18 19
- Fig 19 19
- Fig 20 19
- Fig 21 19
- Installation procedures 19
- Outdoor unit installation 19
- 1 outline of piping 20
- 2 piping size 20
- 3 limitations for one way piping length and vertical height difference 20
- 4 piping connection fig 3 20
- Fig 22 20
- Installation of outdoor unit 20
- Installation procedures 20
- Refrigerant piping 20
- Selection of hte place of installation 20
- After connecting the piping check the joints for gas leakage with gas leakage detector 21
- Caution 21
- Gas pipe 21
- Installation procedures 21
- Liquid pipe 21
- Service port 21
- Service port cap 7 21
- Vacuum pump 21
- Valve rod cap 21
- Way valve 21
- A for solid core wiring or f cable fig 4a 22
- B for strand wiring fig 4b 22
- Fig 25 insulation tube 22
- How to connect wiring to the terminals 22
- How to fixed connection cord and power cable at the cord clamp 22
- Installation procedures 22
- Caution 23
- Electrical requirement 23
- Electrical wiring 23
- Indoor unit side 23
- Installation procedures 23
- Caution 24
- Installation procedures 24
- Mount the cover plate and the intake grill 24
- Test running 24
- Fig 34 25
- Fig 35 25
- Installation procedures 25
- Mount the intake grill 25
Похожие устройства
- Haier AC182ACBIA Инструкция по эксплуатации
- Haier AU182AFBEA Сервис мануал
- Haier AU242AHBIA Сервис мануал
- Haier AU242AHBEA Сервис мануал
- Haier AU282AHBEA Сервис мануал
- Haier AU28NAHBEA Сервис мануал
- Haier AU36NAIBEA Сервис мануал
- Haier AU42NAIBEA Сервис мануал
- Haier AU52NAIBEA Сервис мануал
- Haier AU88NATBEA Инструкция по эксплуатации
- Haier AU88NATBEA Сервис мануал
- Haier AP88NACBEA Инструкция по эксплуатации
- Haier AP88NACBEA Сервис мануал
- Haier AD88NAHBEA Инструкция по эксплуатации
- Haier AD88NAHBEA Сервис мануал
- Haier AB092ACBHA Инструкция по эксплуатации
- Haier AB092ACBHA Сервис мануал
- Haier AB122ACBHA Инструкция по эксплуатации
- Haier AB122ACBHA Сервис мануал
- Haier HBU-09HA03/R1(B) Инструкция по эксплуатации