Haier AU182AFBEA [270/365] Ports on pcb functions for au242ahbea au88natbea

Haier AU142AFBEA [270/365] Ports on pcb functions for au242ahbea au88natbea
CN1second side of transformer
CN2high pressure switch
CN3
outdoor ambient temperature sensor
CN4primary side of transformer
CN5control port of 4-way valve
CN6
control port 2 of compressornot available for some models)
CN7
control port 2 of compressor 1
CN8
control port 2 of fan motor (not available for some models)
CN9control port 1 of fan motor
CN10low pressure switch
CN11compressor discharging temp. sensor
CN12: outdoor coil temperature sensor
Sconnection port for communication between indoor and outdoor
L1L2L3power supply terminal(herein, no L2, L3 for single phase compressor)
Nport for neutral wire
TEST
port for compulsory running, herein, on ZR side, short connecting the two pins
can enter the compulsory heating; on ZL side, short connecting the two pins can enter
the compulsory cooling.
CT1
current detector
LED1
outdoor LED
>a__WcU[S^ <[c >a`V[e[a`Wc
Ports on PCB functions for AU242AHBEA~AU88NATBEA
-270-

Содержание

Скачать