1
For the purpose of safety, the air
conditioner must be properly grounded in
accordance with specifications.
Always remember to unplug the air
conditioner before opening inlet grill. Never
unplug your air conditioner by pulling on the
power cord. Always grip plug firmly and
pull straight out from the outlet.
Damaged air conditioners are not to be
put into operation. In case of doubt, consult
your supplier.
Use of the air conditioner is to be carried
out in strict compliance with the relative
instructions set forth in the User's Guide.
Installation shall be done by professional
people, don't install unit by yourself.
All electrical repairs must be carried out by
qualified electricians. Inadequate repairs may
result in a major source of danger for the user
of the air conditoiner.
Do not damage any parts of the air
conditioner that carry refrigerant by piercing
or perforating the air conditioner's tubes with
sharp or pointed items, crushing or twisting
any tubes, or scraping the coatings off the
surfaces. If the refrigerant spurts out and gets
into eyes, it may result in serious eye injuries.
Disposal of the old air conditioner
Before disposing an old air conditioner
that goes out of use, please make sure it's
inoperative and safe. Unplug the air
conditioner in order to avoid the risk of
child entrapment.
It must be noticed that air conditioner
system contains refrigerants, which require
specialized waste disposal. The valuable
materials contained in a air conditioner can
be recycled. Contact your local waste
disposal center for proper disposal of an
old air conditioner and contact your local
authority or your dealer if you have any
question. Please ensure that the pipework
of your air conditioner does not get
damaged prior to being picked up by the
relevant waste disposal center, and
contribute to environmental awareness by
insisting on an appropriate, anti-pollution
method of disposal.
Disposal of the packaging of your new
air conditioner
All the packaging materials employed in
the package of your new air conditioner
may be disposed without any danger to the
environment.
The cardboard box may be broken or cut
into smaller pieces and given to a waste
paper disposal service. The wrapping bag
made of polyethylene and the polyethylene
foam pads contain no fluorochloric
hydrocarbon.
Safety Instructions and Warnings
Before starting the air conditioner, read the
information given in the User's Guide
carefully. The User's Guide contains very
important observations relating to the
assembly, operation and maintenance of the
air conditioner.
The manufacturer does not accept
responsibility for any damages that may
arise due to non-observation of the following
instruction.
All these valuable materials may be taken to a
waste collecting center and used again after
adequate recycling.
Consult your local authorities for the name and
address of the waste materials collecting
centers and waste paper disposal services
nearest to your house.
Содержание
- Cassette type air conditioner 1
- Operation installation manual 1
- Cassette type air conditioner 2
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Specifications 4
- Diferent fan speed 5
- Main points of operation 5
- Minute protection function 5
- Operation of air conditioner 5
- Remote control 5
- Anti cold blowing off 6
- Auto restant function to be applied for a necessary situation 6
- Defrosting function 6
- In heating mode the indoor fan will not run immediately after the unit starts up which will the cold air being blow out 6
- In heating mode when frost is formed on the outdoor heat exchanger the air conditioner will automatically defrost for few minutes during defrosting both indoor fan and outdoor fan will stop running when defrosting finishes air condi tioner will automatically be back to running 6
- Main points of operation 6
- The air conditioner absorbs heat form outdoor and releases to indoor when in heating mode therefore the outdoor environmental temperature will affect heating efficiency 6
- Air filter 7
- Air inlet grille 7
- Indoor unit 7
- Operating control panel 7
- Outdoor unit 7
- Part name 7
- Remote receiver compressor lamp timer lamp operation lamp power lamp emergency switch 7
- Swing louver 7
- Be sure to conform with the following important safety precautions the safety precautions should be at hand so that they can be checked at any time when necessary if the air conditoner is transferred to the new user this manual should be as well transferred to the new user 8
- Below are listed four kinds of safety precautions and suggestions 8
- Carefully read the following information in order to operate the air conditioner correctly 8
- Caution 8
- Incorrect operations may result in injures or machine damages in some cases may cause serious consequences 8
- Incorrect operations may result in severe consequences of death or serious injures 8
- Instruction 8
- It must be strictly prohibited where being marked with ì prohibited î otherwise may result in machine damages or endanger the usersípersonal safety 8
- Safety precautions 8
- This information can ensure the correct operation of the machine 8
- Warning 8
- Safety precautions 9
- Warning 9
- Caution 10
- Clean indoor outdoor unit 10
- Clean the air filter 10
- Clean the unit 10
- Maintenance 10
- Take down air inlet grille 10
- Take down the filter 10
- Maintenance 11
- Post season care 11
- Pre season care 11
- Seasonal reserve 11
- Cold air blown out when heating 12
- Insufficient cooling 12
- Insufficient cooling or heating 12
- When trouble happens 12
- Customer need to know 13
- Using directions 13
- Installation tools 14
- Installation preparation 15
- Installation procedures 15
- Selection of installation place 15
- After installation on the ceiling 16
- In case of no ceiling 16
- In the case of existing ceiling 16
- Installation of indoor unit 16
- Installation procedures 16
- Cautions for the water drainage lifting pipe 17
- Installation of water drainage pipe 17
- Installation procedures 17
- Install ornament panel on indoor unit 18
- Installation of ornament panel 18
- Installation procedures 18
- Panel limitation board installation 18
- Piping connection 18
- 092 122 19
- Cautions for piping connection 19
- Installation procedures 19
- 4 purging method the refrigerant is r407c 20
- Installation procedures 20
- To use vacuum pump 20
- Connection of outdoor piping 21
- Crimp connection method of connecting line 21
- Electrical wiring 21
- Installation fixing 21
- Installation of drain elbow 21
- Installation procedures 21
- Wiring connection 21
- Wiring method of straight terminal 21
- Wiring methods 1 wiring method of ring terminal 21
- Wiring of indoor unit 21
- Installation procedures 22
- Wiring connection 22
- The followings are not malfuncition 23
- Troubleshooting 23
- Please check the following things about your air conditioner before making a service call 24
- Troubleshooting 24
- Unit fails to start 24
- Failure code 25
- Check and test run 26
- Installation check and test run 26
Похожие устройства
- Haier AB122ACBJA Инструкция по эксплуатации
- Haier AB142ACBJA Инструкция по эксплуатации
- Haier AB182ACBJA Инструкция по эксплуатации
- Haier AB142ACBFA Инструкция по эксплуатации
- Haier AB182ACBFA Инструкция по эксплуатации
- Haier AB182ACAEA Инструкция по эксплуатации
- Haier AB282ACAEA Инструкция по эксплуатации
- Haier AB42NACAEA Инструкция по эксплуатации
- Vodotok НСП-600 Инструкция по эксплуатации
- Vodotok НСП-800 Инструкция по эксплуатации
- Vodotok PJm80 Инструкция по эксплуатации
- Vodotok PJm100 Инструкция по эксплуатации
- Vodotok PJWm10H Инструкция по эксплуатации
- Vodotok PJWm15H Инструкция по эксплуатации
- Vodotok XRS20/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-180 Инструкция по эксплуатации
- Vodotok XRS32/4-180 Инструкция по эксплуатации
- Vodotok XRS20/6-130 Инструкция по эксплуатации
- Vodotok XRS25/6-130 Инструкция по эксплуатации