Haier AB282ACAEA [29/30] Installation procedure
![Haier AB42NACAEA [29/30] Installation procedure](/views2/1822217/page29/bg1d.png)
27
(1)
3. Install ornament panel on indoor unit.
As shown in Fig . 7, match the position of swing
flap motor with that of the indoor unit piping hole ,
so that ormament panel can be placed on to indoor
unit.
Installation of ornament panel
Place the holding ring on swing flao motor side
teporarily on hooks of the indoor unit. (2 pcs)
Put the other two holding rings on the hooks at
both
side of the indoor unit. (Care should be taken not to
push wiring of swing flap motor into seals).
Screw in all 4 screws under holding ring for about
15mm. (Pancl will rise).
Adjust the ornament panel as per Fig. 7 to cover
opening on the ceiling.
Tighten screws to redrce the thickness of seals
between ornament and indoor unit to 5-8mm.
If indoor unit is at horizontal level and water
drainage is smooth, then, indoor unit height
can be adjusted throrgh holes at corners of
ornament panel.
If screws are not tighten tight,
problems in Fig, 8 might occur.
Tighten screws properly.
If there are still space
after tightening of screws,
please readjust the height
of indoor unit.
(Refer to Fig. 9)
Leave no space.
Fig. 9
Gas leakage.
Gas leakage
from roof.
Contamination
Mist exists and drop down.
Fig. 8
For indoor unit installation, please
refer to Installation Manual.
(2)
1
2
3
4
5
5
_
8mm
3
2
2
1
4
Holding ring
Piping hole position
Swing flap motor
Fig. 7
Seal
Indoor unit
Ceiling material
Ornament panel
Hook
Caution
2. Mounting on high ceiling
(1) Ornament panel can be mounted on ceiling as high as 3 m.
(2) Please install pad as accessary.
Cut open the pad along cutting ling. Use part a only and discard part b . (Refer to Fig. 4)
Install part a of the pad on the place shown in Fig. 5. Refer to Fig. 6.
(3)Wiring on ornament panel
Connecting of wiring of the swing
flap motor on ornament panel. (2 places)
(Refer to Fit . 10)
If connecting is not made, error code
(A7) appears on remote controller. So,
make proper connecting.
Side of ornament panel
Fig. 10
Wiring diagram
Side of indoor unit
Fig. 4
50
Cutting line
100
a
b
Place it on the frame.
Part a of the pad
Leave no space.
Fig. 6
Part a of the pad
Swing flap motor
Fig. 5
1
2
Installation Procedure
Содержание
- Cassette type air conditioner 1
- Operation installation manual 1
- Contents 2
- Cautions 3
- Disposal of the old air conditioner 3
- Disposal of the packaging of your new air conditioner 3
- Cautions 4
- Carefully read the following information in order to operate the airconditioner correctly 5
- Cautions 5
- Safety cautions 5
- Warning 5
- Cautions 6
- Caution 7
- Cautions 7
- Installation 7
- Location 7
- Operating noise 7
- Warning 7
- Wiring 7
- Ab182acaea 8
- Ab282acaea 8
- Ab42nacaea 8
- Air filter 8
- In cooling operation to discharge the water from inside the room 8
- Introduction to spare parts 8
- Outlet 8
- Refrigerant pipe cable line earthing line 8
- Suction grill 8
- Swing fender 8
- Ab182acaea 9
- Caution 9
- Clean indoor outdoor unit 9
- Clean the air filter 9
- Clean the unit 9
- Maintenance 9
- Ab282acaea 10
- Clean air filter 10
- Clean inlet grill 10
- Close inlet grill 10
- Controller 10
- Dismantle air filter 10
- Install air filter 10
- Maintenance 10
- Open inlet grill 10
- Open two othooks 10
- Press the filter signal return key on the 10
- Clean outlet and shell 11
- Dismantle and install swing plate 11
- Fix the swing plate at the bottom 2 dismantle the swing plate 11
- Install inlet grill 6 install air filter 7 close inlet grill 11
- Install swing plate 11
- Maintenance 11
- Take of inlet grill 11
- Take off air filter 11
- Ab42nacaea 12
- Clean the air filter 12
- Maintenance 12
- Clean the air inlet grille 13
- Instruction 13
- Maintenance 13
- Notice 13
- Maintenance 14
- Post season care 14
- Pre season care 14
- Seasonal reserve 14
- The followings are not malfuncition 15
- Trouble shooting 15
- Please check the following things about your air conditioner before making a service call 16
- Trouble shooting 16
- Unit fails to start 16
- Cooled air blown out when heating 17
- Insufficient cooling 17
- Insufficient cooling or heating 17
- When trouble happens 17
- When trouble happens 18
- Attention after finishing installation confirm no refrigerant leakage 19
- Customer need to know 19
- Using directions 19
- Installation procedure 20
- Installation tools 20
- Standard accessories 20
- Caution 21
- Cautions 21
- Customers how to operate and maintain the unit 21
- Don t fail to show customers how to operate unit 21
- Installation procedure 21
- Meanings of warning and cautions 21
- Warning 21
- Warning serious injury or even death might happen if it is not observed 21
- Before installation 22
- Installation procedure 22
- Selection of installation place 22
- Ab182acaea 23
- Ab282acaea 23
- Ab42nacaea 23
- Anchor bolt long nut 23
- Ceiling 23
- Ceiling opening 23
- Ceiling ornament panel 23
- Distance between 23
- Indoor unit 23
- Installation procedure 23
- Note all the above mentioned parts shall be prepared in field 23
- Note dimension of ceiling opening marked with can be as large as 910mm but the matching part of ceiling with ornament panel shall be over 20mm 23
- Ornament panel 23
- Overlap between ceiling and ornament panel shall be 15mm 23
- Preparation for the installation 23
- Suspending bolt 23
- Suspending bolts 23
- Suspending bracket 23
- Installation of indoor unit 24
- Installation procedure 24
- Level polythene pipe 24
- Installation of water drainage pipe 25
- Installation procedure 25
- Refrigerant piping 25
- Installation procedure 26
- 2 check if water drainage is smooth after installation 27
- After wiring 27
- Charge through air outlet or inspecting hole 1200ccd water to see water drainage 27
- Check water drainage in cooling operation 27
- Indoor unit terminial block 27
- Installation procedure 27
- Method of water charging 27
- N 1 2 3 27
- Outdoor unit terminial block 27
- Ph 220 230v 50hz 27
- Power supply 27
- Power supply 3n 380 400v 50hz 27
- Remove cover of control box short connect check terminal of the indoor unit which is on the uper part of indoor unit pcb connect 1ph power to terminal 1 and 2 on terminal block note in this operation fan will be running upon confirmation of a smooth water drainage be sure to cut off power supply and remove short connection of check terminal 27
- W b r y g 27
- W b y g 27
- When wiring is not complete 27
- Installation procedure 28
- Wiring 28
- Installation procedure 29
- Mounting on high ceiling 29
Похожие устройства
- Haier AB42NACAEA Инструкция по эксплуатации
- Vodotok НСП-600 Инструкция по эксплуатации
- Vodotok НСП-800 Инструкция по эксплуатации
- Vodotok PJm80 Инструкция по эксплуатации
- Vodotok PJm100 Инструкция по эксплуатации
- Vodotok PJWm10H Инструкция по эксплуатации
- Vodotok PJWm15H Инструкция по эксплуатации
- Vodotok XRS20/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-130 Инструкция по эксплуатации
- Vodotok XRS25/4-180 Инструкция по эксплуатации
- Vodotok XRS32/4-180 Инструкция по эксплуатации
- Vodotok XRS20/6-130 Инструкция по эксплуатации
- Vodotok XRS25/6-130 Инструкция по эксплуатации
- Vodotok XRS25/6-180 Инструкция по эксплуатации
- Vodotok XRS32/6-180 Инструкция по эксплуатации
- Vodotok XRS40/6-180-W Инструкция по эксплуатации
- Vodotok XRS25/8-180-W Инструкция по эксплуатации
- Vodotok XRS50/9-180 Инструкция по эксплуатации
- Vodotok XRS25/8-180 Инструкция по эксплуатации
- Vodotok XRS32/8-180 Инструкция по эксплуатации