Haier HPU-18HD03 [15/30] Operation hints

Содержание

Operation hints Unit operation Protection devices inside the unit will activate to stop unit operation when ambient temp is extremely low or high When unit is running under high humidity in cooling or dehumidifying mode condensate might appear at outlet grill 3 min delay protection Unit will not restart until 3 min have elapsed for the protection of the unit Fan speed changes When Fan speed is set at Auto in cooling mode it will be automatically reduced as room temp is approaching temp setting In heating mode when room temp reaches temp setting compressor will stop and fan speed LO or stop In dry mode fan speed will change automatically Cold draft prevention In heating mode indoor fan will not run for the first 2 5 min due to cold draft prevention Defrosting When frost accumulates on heat exchanger in heating mode unit will start defrosting automatically During defrosting both indoor and outdoor fan stop After defrosting unit resumes running Use objectively Heat pump works by means of absorbing outside heat to warm room air so outdoor temp degree will affect unit s heating efficiency 13