Haier HSU-22CQ03 [6/20] Parts and functions

Содержание

Parts and Functions Outdoor Unit CONNECTING PIPING AND ELECTRICAL WIRING For models HSU 14CQ03 HSU 14HQ03 INLET Warm air comes out when cooling cool air comes out when heating OUTLET DRAIN HOSË The machine is adaptive in following situation 1 Applicable ambient temperature range Indoor Cooling Outdoor Indoor Heating Outdoor 32 C 23 C 18 C 14 C Maximum D B W B Minimum D B W B Maximum D B Minimum D B 43 C 15 C Maximum D B Minimum D B Maximum D B W B Minimum D B W B 27 C 20 C 24 C 18 C 7 C 8 C 2 If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person The type of connecting wire is H05RN F or H07RN F Series Cooling Heating 07 09 12 14 Type 3G 1 5mm2 Series 07 09 12 14 Type 18 3G2 5mm2 18 3G 1 5mm2 2x 0 75mm2 3G2 5mm2 3x1 5mm2 22 4G 0 75mm2 22 4G 0 75mm2 For H2SM 18CQ03 H2SM 18HQ03 the type of connecting wire is 3G 0 75mm2 3 If the fuse on PC board is broken please change it with the type of T 3 15A 250V 4 The distance between the indoor unit and the floor should be more than 2 0m 5 The wiring method should be in line with the local wiring standard 6 After installation the power plug should be easily reached 7 The waste battery should be disposed properly 8 The appliance is not intended for use by young children or infirm persons without supervision 9 Young children should be supervised to ensure that they do not play with the appliance 1O The appliance must be installed on strong enough supporter 11 The wiring diagram is attached inside the machine 12 The power plug must have acquired the local attestation 4