Haier AW124AAMBA [2/22] The machine is adaptable in following situation

Содержание

The machine is adaptable in following situation 1 Applicable ambient temperature range Indoor side Cooling Outdoor side Maximum Minimum D B W B D B W B 32C 23C Maximum Minimum D B D B 43 C 26 C I8C ISC MC Indoor side Maximum Minimum D B 27 C D B isc Outdoor side Maximum Minimum D B W B D B W B Hcatin 24C 18C 7C 8C_________________________ For cooling only type heating temperature range is invalid 2 II the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person An extend cord is not recommended 3 If the fuse on PC board is broken please change it with the type of 50T 3 15A 250V Attention please I In heating during winter if the dram hole at the bottom plate has rubber lid please pull it out in order to let tile condensed water flow out smoothly 2 When the outdoor ambient temperature is below TC the air conditioner may have some water frozen during working Therefore please pay attention to the running of the fan and notice if there s abnormal sound tn running If there s no abnormal phenomenon ii can continue running Otherwise it indicates that the bottom plate of the conditioner is frozen So when the outdoor temperature is below O C during heating please remove the robber lid from the bottom of chassis to let the condensate water run out from it to avoid freezing of the water 3 After installation the power plug should be easily reached 4 The waste battery should be disposed properly A 5 The wiring method should be in line with the local wiring standard 1

Скачать