5.2 General view and main components
fig. 20- General view - FL D C24
fig. 21- General view - FL D C32
5.3 Hydraulic circuit
fig. 22- Heating circuit
5.4 Technical data table
3244
14
194
22
278
126
27
136
137
36
95
42
114
56
74 37
78
81
3244
14
194
22
278
27
136
137
36
95
126
42
114
56
74 37
78
81
Data Unit FL D C24 FL D C32
Max. heating capacity kW 25.8 34.4 (Q)
Min. heating capacity kW 8.3 11.5 (Q)
Max. Heat Output in heating kW 23.5 31.3 (P)
Min. Heat Output in heating kW 7.0 9.7 (P)
Max. Heat Output in DHW kW 23.5 31.3
Min. Heat Output in DHW kW 7.0 9.7
Efficiency Pmax (80-60°C) % 91.0 91.0
Efficiency 30% % 89.6 89.8
NOx emissions class - 3 (<150 mg/kWh) (NOx)
Burner nozzles G20 no. x Ø 11 x 1.35 15 x 1.35
Gas supply pressure G20 mbar 20.0 20.0
Max. gas pressure at burner (G20) mbar 12.0 12.0
Min. gas pressure at burner (G20) mbar 1.5 1.5
Max. gas flow G20
m
3
/h
2.73 3.64
Min. gas flow G20
m
3
/h
0.88 1.22
Burner nozzles G31 no. x Ø 11 x 0.79 15 x 0.79
Gas supply pressure G31 mbar 37 37
Max. gas pressure at burner (G31) mbar 35.0 35.0
Min. gas pressure at burner (G31) mbar 5.0 5.0
Max. gas flow G31 kg/h 2.00 2.69
Min. gas flow G31 kg/h 0.65 0.90
Max. working pressure in heating bar 3 3 (PMS)
Min. working pressure in heating bar 0.8 0.8
Max. heating temperature °C 90 90 (tmax)
Heating water content liters 1.0 1.2
Heating expansion vessel capacity liters 8 10
Heating expansion vessel precharge pressure bar 1 1
Max. working pressure in DHW bar 9 9 (PMW)
Min. working pressure in DHW bar 0.25 0.25
DHW flow rate
t 25°C l/min 13.4 17.9
DHW flow rate
t 30°C l/min 11.2 14.9 (D)
Protection rating IP X5D X5D
Power supply voltage V/Hz 230V/50Hz
Electrical power input W 80 90
Electrical power input in DHW W 80 90
Empty weight kg 27 30