Haier HSU-71HEK03/R2(DB)/O [2/8] Content
![Haier HSU-71HEK03/R2(DB)/O [2/8] Content](/views2/1824532/page2/bg2.png)
2
Content
Preparation p3
Accessory parts p3
Selection pipe p3
Drawing for the installation of indoor and outdoor units p3
Indoor unit p5
Outdoor unit p6
Refrigerant charge label p8
Check for installation and test run p8
Содержание
- For room air conditioner 1
- Installation manual 1
- Content 2
- Accessory parts 3
- Indoor unit 3
- Model liquid pipe ø gas pipe ø 3
- Model max rated current 3
- Necessary tools for installation 3
- Outdoor unit 3
- Power requirements 3
- Power source 3
- Preparation 3
- Selection of installation place 3
- Selection of pipe 3
- Drawing for the installation of indoor and outdoor units 4
- Fixing of outdoor unit 4
- Model dimensions 4
- Optional parts for piping 4
- Rear left left rear right 4
- The outdoor unit unit mm 4
- The picture above is just for your reference please refer to the actual product purchased 4
- Drawing of pipe 5
- Fitting of the mounting plate and positioning of the wall hole 5
- Fixing the indoor unit body 5
- Hsu 26hek03 r2 db i 5
- Hsu 35hek03 r2 db i 5
- Hsu 53hek03 r2 db i 5
- Hsu 71hek03 r2 db i 5
- Indoor unit 5
- Installation of the indoor unit 5
- Making a hole on the wall and fitting the piping hole cover 5
- Unloading of indoor unit body 5
- Caution 6
- Connecting the indoor outdoor electric cable 6
- Connection of pipes 6
- Dred function indoor unit cont 6
- Electrical connection 6
- Forced fastening without careful centering may damage the threads and cause a leakage of gas 6
- Gas side 12 mm 1 2 55n m 6
- Gas side 15 8mm 5 8 60 n m 6
- Half union flare nut 6
- If the supply cord is damaged it must be replaced by the manufacturer or its service agent or a similar qualified person the type of connecting wire and power cable is h05rn f or h07rn f 6
- Indoor unit 6
- Installation of outdoor unit 6
- Liquid gas side9 2mm 3 8 42 n m 6
- Liquid side6 5mm 1 4 18n m 6
- Model base charge pre charge pipe length additional charge amount 6
- Pipe diameter fastening torque 6
- Pipe diameter ø fastening torque 6
- Power cable 6
- Removing the wiring cover 6
- Torque wrench spanner 6
- When connecting the cable after installing the indoor unit 6
- When connecting the cable before installing the indoor unit 6
- Attaching drain elbow 7
- Caution 7
- Connection of electrical cable 7
- Evacuation method use vacuum pump 7
- Outdoor unit cont 7
- Step 1 7
- Step 2 7
- Step 3 7
- Step 4 7
- Step 5 7
- Step 6 7
- Step 7 7
- Step 8 7
- Check for installation and test run 8
- Check items for test run 8
- Cutting and flaring work of piping 8
- On drainage 8
- Outdoor unit cont 8
- Power source installation 8
- Refrigerant charge label 8
Похожие устройства
- Haier HB2400VD1M20 Инструкция по эксплуатации
- Haier HB2400VD1V20 Инструкция по эксплуатации
- Haier HB3600VD1M22 Инструкция по эксплуатации
- Haier HB3600VD1V22 Инструкция по эксплуатации
- Haier HB4800VD1M22 Инструкция по эксплуатации
- Haier HB4800VD1V22 Инструкция по эксплуатации
- Haier HB6000VD1M22 Инструкция по эксплуатации
- Haier HB6000VD1V22 Инструкция по эксплуатации
- Haier HB6000VD1M22-E Инструкция по эксплуатации
- Haier HB6000VD1V22-E Инструкция по эксплуатации
- Haier HC18D1VAR Инструкция по эксплуатации
- Haier HR18D1VAR Инструкция по эксплуатации
- Haier HC24D1VAR Инструкция по эксплуатации
- Haier HR24D1VAR Инструкция по эксплуатации
- Haier HC30D1VAR Инструкция по эксплуатации
- Haier HR30D1VAR Инструкция по эксплуатации
- Haier HC36D1VAR Инструкция по эксплуатации
- Haier HR36D1VAR Инструкция по эксплуатации
- Haier HC42D1VAR Инструкция по эксплуатации
- Haier HR18D1VAR Сервис мануал