Haier FCE-136BCN2A [7/16] Unit installation
Содержание
- Fan coil type 1
- Operation and installation manual 1
- About this manual 2
- Important notice 2
- Features 3
- Product introduction 3
- Horizontal concealed units 4
- Horizontal concealed units with bottom return air box 4
- Standard drip tray extended drip tray 4
- Unit overall dimensions and weight 4
- Horizontal concealed units with back return air box 5
- Standard dri3 tray extended drip tray 5
- Standard drip tray extended drip tray 5
- Unit overall dimensions and weight 5
- Acceptance inspection 6
- Installation 6
- Installation precautions 6
- Unit installation 6
- Unit installation 7
- Unit installation 8
- Installation inspection startup 9
- Unit maintenance 10
- Common troubles and clearing measures 11
- Troubleshooting 11
- Cautions 12
- Disposal of the old air conditioner 12
- Disposal of the packaging of your new air conditioner 12
- Safety instructions and warnings 12
- Cautions 13
- Safety precautions 13
- Specifications 13
- Cautions 14
- Safety precautions 14
- Warning 14
- Caution 15
- Cautions 15
- Cautions on installation 15
- Location 15
- Safety precautions 15
- Wiring 15
- Notes for safety 16
Похожие устройства
- Pedrollo NK 2/4 кабель 20м Технический паспорт
- Haier FCE-170BCN2A Инструкция по эксплуатации
- Pedrollo NK 2/5 кабель 10м Инструкция по эксплуатации
- Pedrollo NK 2/5 кабель 10м Технический паспорт
- Pedrollo NK 2/5 кабель 20м Инструкция по эксплуатации
- Pedrollo NK 2/5 кабель 20м Технический паспорт
- Pedrollo NK 2/6 кабель 10м Инструкция по эксплуатации
- Pedrollo NK 2/6 кабель 10м Технический паспорт
- Pedrollo NK 2/6 кабель 20м Инструкция по эксплуатации
- Pedrollo NK 2/6 кабель 20м Технический паспорт
- Pedrollo NK 4/3 кабель 10м Инструкция по эксплуатации
- Pedrollo NK 4/3 кабель 10м Технический паспорт
- Pedrollo NK 4/3 кабель 20м Инструкция по эксплуатации
- Pedrollo NK 4/3 кабель 20м Технический паспорт
- Pedrollo NK 4/4 кабель 10м Инструкция по эксплуатации
- Pedrollo NK 4/4 кабель 10м Технический паспорт
- Pedrollo NK 4/4 кабель 20м Инструкция по эксплуатации
- Pedrollo NK 4/4 кабель 20м Технический паспорт
- Pedrollo NK 4/5 кабель 10м Инструкция по эксплуатации
- Pedrollo NK 4/5 кабель 10м Технический паспорт
Unit Installation 4 Assemble lower nut and washer to fix the unit Turn lower nut to adjust levelness ensuring drain of condensate and then tighten upper nut Note Levelness adjustment shall take fan coil case as the reference Its coil and drip tray have been designed with slight inclination for water drain Air duct connection Air ducts made of galvanized steel sheet of certain thickness provided by the installer may be connected to the flanges at air inlet outlet of the unit Refer to Unit Overall Dimensions and Weight Insert air ducts into flanges and fix with screws If air duct and flange have different sizes they should be connected through a site made adapter Connection of air supply cabinet and air duct insert air duct into flange and fix them horizontally with screws or rivets Same for connection of return air box Pipeline Connection Connection of chilled water pipeline Connect chilled water pipe to the coil with a 3 4 external threaded connector The fan coil has its inlet at bottom and outlet on top See Unit Overall Dimensions and Weight for dimensions of coil connection Connection of condensate pipeline Condensate pipe may be of PVC or steel and shall have a flexible connection The hose shall not be more than 300mm long and should be transparent It shall be tightly fixed with a clip without leakage It is suggested the drain pipe inclination shall be at least 1 50 Note To avoid dew formation during cooling chilled water pipe and condensate pipe must be thermally insulated with careful treatment at insulation ends Electric Wiring Make electric wiring according to the wiring diagram shipped with the equipment The earth point provided on the unit shall be connected to the grounding system of the building All electric connections shall comply with local electric regulations Note Before maintenance the power supply shall be disconnected to prevent human injury Connecting wires shall be made of copper Other conducting materials may result in overheating and unit damage 6