Kentatsu KSTT240HFAN1 [5/12] Names and functions of air conditioner components
![Kentatsu KSTT280HFAN1 [5/12] Names and functions of air conditioner components](/views2/1829789/page5/bg5.png)
3
owner’s manual
Model
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Standard cooling capacity (kW)
Type
Standard heating capacity (kW)
Cooling
Heating
Cooling
Heating
Stanrdard
power (kW)
Standard
current (A)
Rated input current (A)
Rated input power (kW)
Power
supply
Circulating air volume(m
3
/h)
(Indoor)
Noise value
dB(A)
Outline
dimensions
(mm)
Weight
(kg)
Applicable area (m
2
)
Control mode
Cooling
Cooling & heating
Hi. static pressure
67
23.7
23.7
14.4
14.4
15.9 15.9
17.1
10.3
9.6
9.6
28 28
31
220V-240V~ 50Hz
380V-415V 3N~ 50Hz
5100 / 196Pa
61
1350x760x450
1255x700x908
120~160
wire control (standard)
105
187
105
185
KSTT280CFAN1/
KSUN280CFAN3
KSTT280HFAN1/
KSUN280HFAN3
4. MODEL, SPECIFICATION & PARAMETERS
In case any parameters in the following table are changed, no
other notice will be given. The parameters specified on the
nameplate shall prevail.
Table.4-1
Model
KSTT240CFAN1/
KSUN240CFAN3
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Outdoor unit
Indoor unit
Standard cooling capacity (kW)
Type
Standard heating capacity (kW)
Cooling
Heating
Cooling
Heating
Stanrdard
power (kW)
Standard
current (A)
Rated input current (A)
Rated input power (kW)
Power
supply
Circulating air volume(m
3
/h)
(Indoor)
Noise value
dB(A)
Outline
dimensions
(mm)
Weight
(kg)
Applicable area (m
2
)
Control mode
Cooling
Cooling & heating
Hi. static pressure
65
220-240V~ 50Hz
380-415V 3N~ 50Hz
1350x760x450
120~160
105
171
Fig.5-1
5. NAMES AND FUNCTIONS OF AIR
CONDITIONER COMPONENTS
6. OPERATION PRECAUTIONS
NOTE
The cooling capacity of the air conditioner is measured in a
standard environment where the indoor dry/wet bulb tempera-
ture is 27°C/19°C and the outdoor dry/wet bulb temperature is
35°C/24°C; the heating capacity is measured in a standard
environment where the indoor dry/wet bulb temperature is
20°C/15°C and the outdoor dry/wet bulb temperature is
7°C/6°C; and the actual cooling/heating capacity changes with
the rise/fall of the indoor/outdoor environment temperature and
relative humidity.
The noise of the unit is measured in the semi noise suppression
lab according to the national standards, and the accuracy extent
is ±3dB(A).
During the actual service, the noise will be changed according
by ducts, and the practical noise value is
about 45dB(A) or lower.(after be installed the mute device.)
External static pressure range of the air conditioner under
experiment is 0 Pa.
Read this operation manual carefully before operating the unit.
Grasp the key points in the manual, and seek help from the con
distributor for any question.
This air conditioner is designed to provide a comfortable room
environment, and is applicable to the purposes described in the
manual only.
outdoor unit
Refrigerant pipe
Indoor unit
Electrical control box
Remote controller
Air outlet pipe, mute box(option)
Air return duct(option)
Drain orifice
Remote controls signal
reciving board
Fixed rated wire controller
(Option, used it before install
the remote controller .)
KSTT240HFAN1/
KSUN240HFAN3
KSTT240-280H(C)FAN1/KSUN240-280H(C)FAN3
174
58 58
1255x700x908
wire control (standard)
22.0
22.0
25
7.5
8.3
12.4
13.6
11.7
19.3
19.3
11.7
12.4
7.5
4250 / 196Pa
Содержание
- Split duct air conditioner 1
- Caution 3
- Important safety information 3
- Warning 3
- Electric scafety requirement 4
- Functions features 4
- Model specification parameters 5
- Names and functions of air conditioner components 5
- Operation precautions 5
- Beat operation 6
- Importants 6
- Maintenance upkeep 6
- Maintenance upkeep of outdoor unit 7
- Operation required before leaving the air conditioner idle for a long period 7
- Phenomena not attributable to faults of air conditioner 7
- Startup after a long period out of service 7
- Faults of air conditioner and cause 8
- Faults of remote controller and cause 8
- The set temperature is lower than the room temperature during the cooling or the set temperature is higher than the room temperature during the heating 8
- All lamps flashing at 5hz 9
- Defrosting lamp flashing at 5hz alarm lamp flashing at 5hz operation lamp timer lamp flashing at 5hz 9
- Display problem 9
- Eeprom malfunction 9
- Repair 9
- Room temperature sensor malfunction evaporator temperature sensor malfunction condensator temperature sensor malfunction 9
- The pro terminal on pcb of indoor unit without connected to grounding wire or optical coupler on pcb malfunction 9
- Timer lamp flashing at 5hz operation lamp flashing at 5hz 9
- Trouble shooting 9
- Water level check malfunction 9
Похожие устройства
- Kentatsu KSTT240HFAN1 Инструкция по монтажу
- Kentatsu KSTT280HFAN1 Инструкция по эксплуатации
- Kentatsu KSTT280HFAN1 Инструкция по монтажу
- Kentatsu KSFU120CFDN3 Инструкция по монтажу
- Kentatsu KSFU120CFDN3 Технические данные
- Kentatsu KSFU120CFDN3 Инструкция по эксплуатации
- Kentatsu KSRU120CFDN3 Инструкция по монтажу
- Kentatsu KSRU120CFDN3 Технические данные
- Kentatsu KSRU120CFDN3 Инструкция по эксплуатации
- Kentatsu KSRU61HFDN1 Инструкция по монтажу
- Kentatsu KSRU61HFDN1 Инструкция по эксплуатации
- Kentatsu KSRU70HFDN1 Инструкция по монтажу
- Kentatsu KSRU70HFDN1 Инструкция по эксплуатации
- Kentatsu KSFU61HFDN1 Инструкция по монтажу
- Kentatsu KSFU61HFDN1 Инструкция по эксплуатации
- Kentatsu KSFU70HFDN1 Инструкция по монтажу
- Kentatsu KSFU70HFDN1 Инструкция по эксплуатации
- Kentatsu KSFU76HFDN3 Инструкция по монтажу
- Kentatsu KSFU76HFDN3 Инструкция по эксплуатации
- Kentatsu KSFU140HFDN3 Инструкция по монтажу