Midea MS11D-12HRN1 Сервис мануал онлайн [47/56] 624621

Midea MS11D-24HRN1 Сервис мануал онлайн [47/56] 624624
DM12-01.01.07en Neola On-off
Service manual 47
1.3
T2
High speed 43
Medium speed 46
Low speed 48
About the setting defrosting time:
condition runtimeminute Defrosting timeminute
Case 1 AB1 Runtime=45 10
Case 2 AB1 45runtime≤60 7.5
Case 3 AB1 60runtime≤90 8.5
Case 4 AB1 90runtime≤120 10
Case 5 AB1 120runtime 12
2The cumulative compressor running time is over 45 minutes .Meanwhile the indoor fan off or run in
breeze mode automatically (for Anti-cold wind function), AC will enter defrosting mode and the
defrosting time is ten minutes.
3If the AC haven't defrost before running and the indoor fan running in slow mode over 2 minutes,
meanwhile 1.2 and 1.3 is satisfied and the cumulative compressor running time is over 45 minutes, AC
will enter defrosting mode and the defrosting time is ten minutes.
l
Condition of ending defrosting:
If any one of the following items is satisfied, the defrosting will terminate and the machine will turn to
normal heating mode.
(1) The defrosting time is reached to the setting value.
(2) After defrosting for 3 minutes,T22.
(3)
If the defrosting time is between 2 and 4 minutes, T2
max-
T2
min
2.