Midea MO11D-18HN1 [51/56] Troubleshooting

Midea MS11D-24HRN1 [51/56] Troubleshooting
DM12-01.01.07en Neola On-off
Service manual 51
11. Troubleshooting
11.1 Indoor unit error display
For 7k, 9k, 12k, 18k
Display Operation lamp flash times
Timer lamp
Failure
E1 1 X EEPROM error
E2 2 X Zero crossing detection error
E3 3 X Indoor fan speed has been out of control
E4 4 X Default
E5 5 X Indoor room temperature sensor T1 open circuit
E6 6 X Evaporator coil temperature sensor T2 open
E7 7 X Condenser coil temperature sensor T3 open
EC 2 O Refrigerant leak detection error
O light X off flash
For 21K, 24K
Display Operation lamp flash times
Timer lamp
Failure
E1 1 X EEPROM error
E2 2 X Zero crossing detection error
E3 3 X Indoor fan speed has been out of control.
E4 4 X Default
E5
5 X
Indoor room temperature sensor T1 open circuit
or short circuit
E6
6 X
Evaporator coil temperature sensor T2 open
circuit or short circuit
E7 7 X Condenser coil temperature sensor T3 open
EC 2 O Refrigerant leak detection error
E8
8 X
Outdoor fan speed has been out of control or
outdoor unit phase error.
E9 9 X Indoor unit and outdoor unit communication error
O light X off flash