Midea MS11D-18HRDN1 / MO11D-18HRDN1 [6/56] Operational
![Midea MS11D-18HRDN1 [6/56] Operational](/views2/1831740/page6/bg6.png)
Neola Inverter DM13-01.01.12 en
6 Service manual
Do not install the product where the noise or hot air from the outdoor unit could damage
the neighborhoods.
It may cause a problem for your neighbors.
Use two or more people to lift and transport the product.
Avoid personal injury.
Do not install the product where it will be exposed to sea wind (salt spray) directly.
It may cause corrosion on the product. Corrosion, particularly on the condenser and evaporator fins,
could cause product malfunction or inefficient operation.
Operational
Do not expose the skin directly to cool air for long periods of time. (Do not sit in the
draft).
This could harm to your health.
Do not use the product for special purposes, such as preserving foods, works of art, etc.
It is a consumer air conditioner, not a precision refrigerant system.
There is risk of damage or loss of property.
Do not block the inlet or outlet of air flow.
It may cause product failure.
Use a soft cloth to clean. Do not use harsh detergents, solvents, etc.
There is risk of fire, electric shock, or damage to the plastic parts of the product.
Do not touch the metal parts of the product when removing the air filter. They are very
sharp.
There is risk of personal injury.
Do not step on or put anything on the product. (outdoor units)
There is risk of personal injury and failure of product.
Always insert the filter securely. Clean the filter every two weeks or more often if
necessary.
A dirty filter reduces the efficiency of the air conditioner and could cause product malfunction or
damage.
Do not insert hands or other object through air inlet or outlet while the product is
operated.
Содержание
- Neola inverter series 1
- Contents 2
- Installation 3
- Precaution 3
- Safety precaution 3
- Warning 3
- Caution 5
- Operational 6
- Function 8
- Model names of indoor outdoor units 8
- Ms11d 24hrdn1 mo11d 24hrdn1 8
- Dm13 01 1 2en neola inverter 11
- Service manual 11 11
- Specification 11
- Neola inverter dm13 01 1 2 en 12
- Service manual 12
- Dm13 01 1 2en neola inverter 13
- Service manual 13 13
- Neola inverter dm13 01 1 2 en 14
- Service manual 14
- Dimension 15
- Outdoor units 17
- 04 2 17 2 19 2 11 1 81 1 72 1 67 18
- 33 2 48 2 50 2 41 2 07 1 96 1 91 18
- 35 2 50 2 52 2 43 2 08 1 98 1 92 18
- 40 2 56 2 58 2 48 2 13 2 02 1 97 18
- 55 2 72 2 74 2 64 2 27 2 15 2 09 18
- 61 0 66 0 72 0 79 0 80 0 81 0 84 18
- 62 0 67 0 73 0 80 0 81 0 82 0 85 18
- 64 0 69 0 75 0 82 0 83 0 85 0 88 18
- 73 0 78 0 85 0 93 0 95 0 96 1 00 18
- 86 1 99 2 00 1 93 1 65 1 57 1 53 18
- 92 2 04 2 06 1 99 1 70 1 62 1 57 18
- 93 3 13 3 15 3 04 2 61 2 47 2 41 18
- Capacity tables 18
- Neola inverter dm13 01 1 2 en 18
- Service manual 18
- ºc 25ºc 30ºc 35ºc 40ºc 45ºc 50ºc 18
- Dm13 01 1 2en neola inverter 21
- Indoor outdoor 21
- Refrigerant cycle diagram 21
- Service manual 21 21
- Indoor units 22
- Wiring diagram 22
- Outdoor units 23
- 153kgf cm 25
- 163kgf cm 25
- 255kgf cm 25
- 265kgf cm 25
- 357kgf cm 25
- 367kgf cm 25
- And 10 1 25
- And 16 1 25
- And 25 2 25
- And 6 0 5 25
- Connecting the cables 25
- Dm13 01 1 2en neola inverter 25
- Installation details 25
- Mm inch n cm n cm 25
- On the nameplate which located on the side panel of the unit please refer to the nameplate before 25
- Outside diameter torque additional 25
- Pipe length and the elevation 25
- Rated current of appliance nominal cross sectional area mm² 25
- Selecting the cable fuse and switch 25
- Service manual 25 25
- The cable size and the current of the fuse or switch are determined by the maximum current indicated 25
- The pipe length and refrigerant amount 25
- The power cord of connect should be selected according to the following specifications sheet 25
- Tightening torque 25
- Wrench torque sheet for installation 25
- Ф12 1 2 3500 25
- Ф6 5 1 4 1500 25
- Ф9 2 3 8 2500 25
- Installation for the first time 27
- Adding the refrigerant after running the system for many years 30
- Re installation while the indoor unit need to be repaired 31
- Re installation while the outdoor unit need to be repaired 33
- Caution 36
- Operation characteristics 36
- Abbreviation 37
- Display function 37
- Electronic function 37
- Main protection 38
- Operation modes and functions 39
- Compressor running rules 42
- Heating mode 42
- If users switch on ac by remote controller the compressor will run at the fmax frequency for 7 42
- Minutes according to outdoor ambient temp during the 7 minutes the frequency limitation is active 42
- Minutes later the compressor running frequency will be controlled as below 42
- Neola inverter dm13 01 1 2 en 42
- Service manual 42
- The compressor frequency will not be limited 42
- The maximum operation frequency of the compressor after starting submits to the following rule 42
- Defrosting action 46
- For 18k 24k models 46
- For 9k 12k models 46
- Neola inverter dm13 01 1 2 en 46
- Service manual 46
- Xx 60 s for 18k models 46
- Xx 90 s for 24k models 46
- Indoor unit error display 51
- Troubleshooting 51
- Diagnosis and solution 52
Похожие устройства
- Midea MS11D-18HRDN1 / MO11D-18HRDN1 Технические данные
- Midea MS11D-18HRDN1 / MO11D-18HRDN1 Инструкция по монтажу
- Midea MS11D-18HRDN1 / MO11D-18HRDN1 Инструкция по эксплуатации
- Сибконтакт APC 500 Руководство по эксплуатации
- Midea MS11D-24HRDN1 / MO11D-24HRDN1 Сервис мануал
- Midea MS11D-24HRDN1 / MO11D-24HRDN1 Технические данные
- Midea MS11D-24HRDN1 / MO11D-24HRDN1 Инструкция по монтажу
- Midea MS11D-24HRDN1 / MO11D-24HRDN1 Инструкция по эксплуатации
- Сибконтакт ИнСтаб IS550 Руководство по эксплуатации
- Сибконтакт ИнСтаб IS800 Руководство по эксплуатации
- Midea M2OC-14HRDN1 Технические данные
- Midea M2OC-14HRDN1 Инструкция по эксплуатации
- Midea M2OC-14HRDN1 Инструкция по монтажу
- Midea M2OC1-18HRDN1 Технические данные
- Midea M2OC1-18HRDN1 Инструкция по эксплуатации
- Midea M2OC1-18HRDN1 Инструкция по монтажу
- Midea M3OC1-21HRDN Технические данные
- Midea M3OC1-21HRDN Инструкция по эксплуатации
- Midea M3OC1-21HRDN Инструкция по монтажу
- Midea M3OC1-27HRDN Технические данные