Panasonic CS-A12ATP5 [3/56] Indoor unit

Panasonic CU-A24ATPT5 [3/56] Indoor unit
Indoor Unit
Sensing The Room Temperature
Room Temperature Sensor (thermistor)
Starting Current Control
Indoor Fan is delayed for 1.6 seconds at the
starting
Time Delay Safety Control
Restarting is inhibited for apporox. 3 minutes
Circuit Protection Control
30 seconds forced operation of the
compressor
Indoor Fan Speed Control
High, Med, Low
Operation Indication Lamps (LED)
POWER
(green) ......... Lights up in operation
AIR SWING
(red)......... Automatic Airflow
Direction in operation
TIMER
(orange) ........ Timer in operation
SLEEP
(orange) ........ Sleep Mode Auto in
operation
Soft Dry Operation Mode
Intermittent operation of Fan at low speed
Room Temperature Control
Maintains the room temperature accordance
with the Setting Temp.
Hot-start Control (Heating)
The indoor fan stops until the Evaporator
piping temperature will be reached.
Automatic Restarting Control
7 minutes automatic restarting at Cooling,
Soft Dry operation.
Sleep Mode Auto Control
The Fan is switched to Low fan speed and the
unit will be stopped after 5 hours
The setting temperature will be raised by 1°C
at the starting and by 1°C one hour later (Soft
Dry of Cooling Operation)
The setting temperature will be dropped by
2°C at the starting and by 3°C one hour later
(Heating Operation)
Deice (defrost) Control
Both the indoor and outdoor fan stops
during deicing
Hot start after deice ends.
Starts operation when indoor piping
temperature drops below temperature
setting 60 ± 10 minutes after heating
start or deice ends
Operations LED flashes
Overload Protection
Thermostat OFF if the Piping
temperature exceeds 100°C
Automatic Operation Determination
Select cooling, dry or heating with the
indoor intake sensor
25°C or higher ........... cooling
21 to 24°C .................. dry
20°C or lower ............. heating
5-minutes automatic restarting is
activated instead of 7-minutes.
3
CS-A12ATP5 CU-A12ATP5 / CS-A18ATP5 CU-A18ATPT5 / CS-A24ATP5 CU-A24ATPT5