Starmix iPulse H 1635 Safe Plus [25/324] Commissioning

Starmix iPulse H 1635 Safe Plus [25/324] Commissioning
en- 25
* je nach Ausstattungsvariante
4 Commissioning
4.1 Before every use
Make sure that the following conditions are met:
r Vacuum cleaner, mains cable, suction hose and accessories
are not damaged.
r All lters have been inserted and are not damaged.
4.2 Switching on and off
The plug socket on the vacuum cleaner remains always under
voltage, regardless of the main switch position.
l WARNING!
Danger of injury by automatically starting power tool!
Switch off power tool or pneumatic tool before connecting to
the vacuum cleaner.
NOTE
With switch in position >0<, the plug socket on the vacuum
cleaner can be used as an extension cable.
l Power consumption: vacuum cleaner + connected power
tool (max. 2000 W) max. 16 A.
4.2.2 Switching on the vacuum cleaner
Functions see „3 Display and control elements“ on page 24.
Insert plug into plug socket.
Set switch to position >IR<.
Vacuum cleaner starts immediately.
or:
Set switch to position >A< or >AR<.
Vacuum cleaner is in standby mode for power tools.
4.2.3 Setting the motor speed*
Adjust motor speed at the switch.
4.2.4 Setting the suction hose diameter*
Set suction hose diameter at the switch.
l CAUTION!
Selector switch for minimum air volume ow signal (horn and
light) on vacuum cleaners with dust classes „M“ and „H“
In the modes >AR< and >IR< the following setting is made,
depending on the diameter of the hose:
Selector switch for
suction hose inner diameter
Volume air ow
35 mm
70 l/s
27 mm
41 l/s
21 mm
25 l/s
The speed can be adjusted individually after setting the hose
diameter.
4.2.5 Switching off the vacuum cleaner
Set switch to position >0<.
Vacuum cleaner is switched off.
After switching off, pull the mains plug out.
Roll up mains connection cable.
Store the mains connection cable on the cable hook.
Store the suction tube by inserting it into the accessories holder*
on the container rear wall.
Put the suction hose ends together so that no dirt particles leak
out.
Remove Power tool.
5 Operating modes
When using the handlebar, suction power can be set with the
auxiliary air slide.
5.1 Sucking up dry materials
Only use a dry lter, vacuum cleaner and accessories, so that
the dust does not stick and or cake.
When vacuuming soot, cement, plaster or similar dusts: Insert a PE
disposal bag in the dirt container. Always use PE disposal bags in
combination with folded lter cartridges.
NOTE
M, H and H-asbestos class vacuum cleaners should be preferably
used as vacuum cleaners for dry dusts.
5.2 Sucking up liquids
l WARNING!
Electrical shock hazard!
If any foam or liquid is discharged, immediately switch off the
vacuum cleaner.
Empty dirt container and folded lter cartridge.
NOTE
1
1
Regularly clean the water level sensors (1)
and inspect for signs of damage.
Vacuum cleaning without eece lter bags.
The folded lter cartridge designed for wet vacuum cleaning.
The built-in sensor switches the motor off when the container is
full. The handling of the vacuum cleaner can be compromised by
a full container.
Empty container (see „7 Emptying the container“ on page 26).
NOTE
If the vacuum cleaner is not switched off, the re-start protection
remains effective. The vacuum cleaner is ready for operation only
after the unit has been switched off and switched on again.