Beko hic 64403 x [10/44] Installation and connection

Содержание

Installation and connection Connecting the power cable The product must be installed in accordance with all local gas and electrical regulations 1 If a power cable is not supplied together with your product a power cable that you would select from the table Technical specifications not install the hob on places with sharp l W ledges or corners BbZ There is the risk of breaking for glass ceramic surface Electrical connection Connect the product to a grounded outlet line protected by a fuse of suitable capacity as stated in the Technical specifications table Have the grounding installation made by a qualified electrician while using the product with or without a transformer Our company shall not be liable for any damages that will arise due to using the product without a grounding installation in accordance with the local regulations DANGER The product must be connected to the mains supply only by an authorised and qualified person The product s warranty period starts only after correct installation Manufacturer shall not be held responsible for damages arising from procedures carried out by unauthorised persons A DANGER page 8 in accordance with the electrical installation at your home must be connected to your product by following the instructions in cable diagram If it is not possible to disconnect all poles in the supply power a disconnection unit with at least 3 mm contact clearance fuses line safety switches contactors must be connected and all the poles of this disconnection unit must be adjacent to not above the product in accordance with IEE directives Failure to obey this instruction may cause operational problems and invalidate the product warranty _______________ dditional protection by a residual current rcuit breaker is recommended E 2 Open the terminal block cover with a screwdriver 3 Insert the power cable through the cable clamp below the terminal and secure it to the main body with the integrated screw on cable clamping component 4 Connect the cables according to the supplied diagram e P wer ca e must not clamped bent or Arapped or come into contact with hot parts of the product A damaged power cable must be replaced by a qualified electrician Otherwise there is risk of electric shock short circuit or fire Connection must comply with national regulations The mains supply data must correspond to the data specified on the type label of the product Type label is at the rear housing of the product Power cable of your product must comply with the values in Technical specifications table DANGER Before starting any work on the electrical installation disconnect the product from the mains supply There is the risk of electric shock 5 After completing the wire connections close the terminal block cover 6 Route the power cable so that it will not contact the product and get squeezed between the product and the wall E 10 EN Power cable must not be longer than 2 m because of safety reasons