Condtrol 24X (2-3-041) с поверкой Инструкция по эксплуатации онлайн

User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
User manual
OPTICAL LEVEL
CONDTROL 24X/32X/ Spektra 32
DELIVERY PACKAGE
1. Opcallevel–1pc.
2. 2-mmhexwrench-1pc.
3. Adjusngpin-1pc.
4. Usermanual–1pc.
5. Hardcase–1pc.
OPERATION
1. Instrument set-up and leveling
a) Set desired height of the tripod
and place it on the ground. Use the
aachment screw to ghtly x the
opcallevelonthetripod(Figure2).
b) Rotate the liing screws A, B, C to
install the bubble vial in the center.
By rotang the A and B screws
simultaneously,movethebubbletothe
right.RotaonofthescrewCwillmove
thebubbleback(Figure3).
Congratulaonsonyourpurchaseofopcallevel24X/32X/Spektra32
CONDTROL.Safetyinstruconsprovidedinthisusermanualshouldbe
carefullyreadbeforeyouusetheproductfortherstme.
SAFETY REGULATIONS
Aenon!Thisusermanualisanessenalpartofthisproduct.Theuser
manualshouldbereadcarefullybeforeyouusetheproductfortherst
me. If the product is given to someone for temporary use, be sure to
encloseusermanualtoit.
-Donotmisusetheproduct.
- It is prohibited to disassemble or repair the product yourself. Entrust
productrepairtoqualiedpersonnelanduseoriginalsparepartsonly.
-Storetheproductbeyondreachofchildrenandunauthorizedpeople.
- Do not use the product in explosive environment,close to ammable
materials.
FUNCTIONS/APPLICATIONS
Opcallevels24X/32X/Spektra32CONDTROLareprofessionalmeasuring
instruments. They are equipped with a compensator with a magnec
dampingsystemwithworkingrange±15‘.Itallowstoquicklyandcorrectly
makehigh-precisionmeasurements.
CONDTROL opcal levels have 24X* and 32X** magnicaon telescope
withcoatedopcs,whichsignicantlyimprovesvisibilityandmakesaiming
toremoteobjectseasier.Theyhaveahorizontallimbwitha1°graduaon
marksandliingscrews,aswellasan opcal sight on thetelescopefor
convenienttargetsearch.
*-24Х
**-32Х и Spektra 32
ExTERNAL APPEARANCE
A
C
B A
C
B
2. Aiming and focusing
а)Grid:
Pointthetelescopeonabrightsurfaceorlevelingsta,usingthesight.
Rotatethe eyepieceunl youachieve a clear andbright image of the
grid.
в)Aiming:
Rotate the focusing screw forward to focus on the sta
standing at longer distance or back to focus on the sta
standingatcloserdistanceunlaclearimageappearson
the screen.Rotate the horizontaldrive screw to posion
theimageofthestaatthecenteroftheeldofview.
3. Measurements
а)Exceedence:
Aerpoinngonthestatakethereadingsofthemiddle
line,asshownonFigure4.(thereadingis1.195m).
в)Distance:
Take the readings of the upper and boom stadia lines.
Distancebetweentheinstrumentandthestawillbethe
following:
(Reading of the upper line – reading of the boom line) х100,
AsshownontheFigure4:
(1.352m-1.038m)х100=31.4m
с)Angle:
Point the vercal line of the grid to the
targetAandtaketheanglereadingαonthe
limb.PointtothetargetBandtaketheangle
readingβonthelimb.TheanglebetweenA
andBwillbe-α-β(Figure5).
ACCURACY CHECK AND ADJUSTMENT
Despite the fact that all optical levels with compensator are adjusted
atthefactory,itisnecessarytocarryoutaccuracycheckbeforeuse.
1. Checking the circular bubble vial
а) Adjust the lifting screws to center the bubble vial and rotate the
telescopeby180°.Thebubblevialshouldremaininthecenter(Figure6).
b) If the bubble vial is not in the center, it is necessary to perform
adjustment.
с)Rotatetheliftingscrewstomovethebubblevialhalfwaytothecenter
(Figure7).
d) Turn 2 adjusting screws to
adjustthepositionofthebubble
vial(Figure7).
e)RepeatstepsfromAtoDuntil
the bubble vial doesn’t deviate
fromthecenter(Figure8).
1
2
6
13
15
9
11
7
12
3
4
8
10
5
1
2
14
13
9
1.Objecvelens
2.Opcalpeepsight
3.Circularvialmirror
4.Eyepiececover
5.Adjusngscrewforsighngline
6.Eyepiece
7.Circularbubblevial
8.Horizontalcirclereferencemark
9.Horizontalcircle
10.Adjusngscrewsofcircularbubblevial
11.Liingscrews
12.Tripodmount5/8“(ontherearside)
13.Horizontaldrivescrews
14.Focusingscrew
15.Base
TECHNICAL SPECIFICATIONS
24x 32x Spektra 32
Standarddeviationfor1km
double
2 mm 1.5 mm 1.5 mm
Image Direct
Magnification 24x 32x 32x
Objectiveaperture 38mm 36mm
Minimalviewingdistance 0.6m
StadiaRatio 100
LevelvialSensitivity 8’/2mm
HorizontalCircleGraduation 1°
Typeofcompensator magnetic
Range 15’
SettingAccuracy 0.5”
Protectionrate IP54
Dimensions 190x128x123mm 210x130x145mm
Weight 1.2kg
Thread 5/8”
Figure2
Figure3
Figure4
A
B0
Figure5
Figure6
Center
Deviation of the bubble vial
Move the bubble vial to position
marked by dashed line
(half of deviation)
Figure7
Figure8
Содержание
Похожие устройства
- Instrumax нивелир AL-124 + рейка TS-500 + штатив TR-160 Инструкция по эксплуатации
- CERSANIT NATURE Clean On 011 3/5 DPL EO (S-KO-NTR011-3/5-COn-DL-w) Инструкция по эксплуатации
- PESTAN Confluo Premium Line 300 Инструкция по эксплуатации
- PESTAN Confluo Standard 15х15 Black Glass 4 Инструкция по эксплуатации
- Hammer PSM135 Инструкция по эксплуатации
- Hammer GNR2200 А Инструкция по эксплуатации
- Hammer ACD120C PREMIUM (2 акк) Инструкция по эксплуатации
- Hammer LSM800A Инструкция по эксплуатации
- Hammer ACD144C PREMIUM (2 акк) Инструкция по эксплуатации
- Hammer USM1250C PREMIUM Инструкция по эксплуатации
- Hammer PSM320C PREMIUM Инструкция по эксплуатации
- Hammer USM850C PREMIUM Инструкция по эксплуатации
- Hammer PSM180C PREMIUM Инструкция по эксплуатации
- Hammer USM1050C PREMIUM Инструкция по эксплуатации
- Hammer USM2100A Инструкция по эксплуатации
- Hammer USM2350A Инструкция по эксплуатации
- Hammer GNR5000 А ЭЛЕКТРОСТАРТЕР Инструкция по эксплуатации
- Hammer ACD121A Инструкция по эксплуатации
- Hammer ACD121B (2 акк) Инструкция по эксплуатации
- Hammer ACD142Li (2 акк) Инструкция по эксплуатации